Introduction
  • Requirements/Basics: Basic knowledge of Modbus is necessary.
  • Abbreviations: Definitions of key terms such as DTM (Digital Transmitter) and OCS (Open Communication System).
  • Limitation of Liability: The manufacturer is not liable for damages due to misuse or unauthorized modifications.
  • Copyright Protection: The manual is protected by copyright and cannot be reproduced without permission.
  • Spare Parts: Only genuine spare parts should be used to avoid damage.
  • Customer Service: Contact information is available for technical support.
Safety
  • Intended Use: The transmitter is designed for measuring pressure and temperature, transmitting data via RS485 using Modbus RTU protocol.
  • Explanation of Symbols: Warning notes and symbols are explained to prevent accidents and damage.
Product Overview

The manual provides a visual overview of the Digital Transmitter DTM.OCS.S.

Commissioning
  • Unpacking: Instructions for safely unpacking the transmitter.
  • Safety Notes: Important safety precautions during installation and operation.
  • Installation: Guidelines for proper installation to avoid damage and ensure accurate measurements.
Communication
  • Summary: Communication is via RS485 using Modbus protocol at 9600 baud.
  • Physical Interface: Requires a Modbus compatible RS485-USB converter.
  • Software Interface: Details on Modbus protocol, including function codes and data transmission.
Modbus Commands
  • Details on reading pressure and temperature values, changing Modbus address, and other commands using Hex-Code and Function Codes.
Technical Data

Specifications and performance parameters of the transmitter.

Maintenance
  • Instructions for cleaning, recalibration, and disposal of the transmitter.
Troubleshooting
  • Guidance on resolving error messages related to Modbus commands.
Appendix
  • Mapping of Modbus command codes and revision history.
General Overview: The document is an operating manual for the Digital Transmitter DTM.OCS.S, focusing on communication protocols and maintenance procedures. It details the use of Modbus function codes and custom STS commands for data transmission and device configuration.
Modbus Communication: The manual outlines the Modbus message frame structure, which includes address, function code, data words, and CRC checksum. It emphasizes the importance of a valid CRC for message integrity. The document also describes the custom STS function code (0x64) used for communication with the transmitter, where commands and parameters are ASCII encoded.
STS Commands: The STS command structure allows for various operations such as reading pressure and temperature (MEASURE command), querying available measurement channels (GETPROBE command), and setting parameters like pressure unit and offsets. The document provides examples of command usage and expected responses, including status messages like OK, FAIL, BUSY, and ERROR.
Supported Units: The manual lists supported pressure units (e.g., mH2O, mbar, bar) and temperature units (e.g., °C, °F, K), ensuring compatibility with various measurement standards.
Modbus Standard Commands: Function Codes 3, 4, and 16 are used for standard operations such as reading pressure, temperature, maximum and minimum values, and changing the device's Modbus address. The document provides hex-code examples for these commands.
Technical Data: The manual refers to the data sheet for detailed technical specifications of the transmitter.
Maintenance: Regular maintenance is advised, particularly cleaning the membrane to prevent damage. Specific instructions are provided for cleaning, including precautions against using sharp objects and the removal of plastic parts before descaling.
Cleaning and Maintenance: The document advises against using additional aids for scale removal to prevent membrane damage. For scale deposits, a commercial descaler is recommended, followed by flushing with water. In cases of strong contamination, cleaning with a cotton swab and liquid benzine is suggested, ensuring the membrane is not damaged.
Recalibration and Disposal: The digital transmitter should be returned to STS for recalibration and disposal.
Troubleshooting: The document outlines error messages related to STS Modbus commands, including 'BUSY', 'FAIL', and 'ERROR', with corresponding troubleshooting steps. It also covers error messages for Modbus standard commands, detailing exception codes and their meanings.
Modbus Command Codes: A table provides mapping of Modbus command codes, detailing addresses, formats, ranges, and descriptions for parameters like pressure, temperature, firmware version, and Modbus address.
Appendix and Index: The appendix includes a mapping of Modbus command codes, while the index provides a comprehensive list of topics covered in the manual, such as cleaning, commissioning, communication, disposal, maintenance, recalibration, and troubleshooting.
Contact Information: Contact details for STS Group companies in Switzerland, Italy, Germany, France, and Great Britain are provided, including phone numbers, fax numbers, and email addresses.
See more

Catalog excerpts

Digital Transmitter DTM.OCS.S / DTM.OCS.S/N-1

Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N Doc. No. 10.00.0430 Version: 11.08.2015 These operating instructions must be read by the operator before operation and installation! Translation of the original operating manual

 Open the catalog to page 1
Digital Transmitter DTM.OCS.S / DTM.OCS.S/N-3

Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N

 Open the catalog to page 3
Digital Transmitter DTM.OCS.S / DTM.OCS.S/N-4

Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N Command (Hex-Code, Function Code 16) ...25

 Open the catalog to page 4
Digital Transmitter DTM.OCS.S / DTM.OCS.S/N-5

Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N

 Open the catalog to page 5
Digital Transmitter DTM.OCS.S / DTM.OCS.S/N-6

Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N 1.1 Requirements/Basics You need basic knowledge of Modbus. Digital Transmitter Open Communication System Zero-point pressure Nominal pressure Data word Data byte Protocol Data Unit Limitation of Liability All information and notes in these instructions have been put together under consideration of the applicable standards and provisions, the state of the art and our many years of insights and experiences. The manufacturer assumes no liability for damage due to:  Non-observation of these instructions  Non-intended use  Use of untrained...

 Open the catalog to page 6
Digital Transmitter DTM.OCS.S / DTM.OCS.S/N-7

Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N The manufacturer guarantees for the function of the applied process technology and the indicated performance parameters. The warranty period shall commence at the time of delivery of the device to the customer. Components shall be excluded from the guarantee and claims for defects if the damage has been caused by wear. 1.4 Copyright Protection The operating instructions must not be provided to any third parties without the written consent of the manufacturer. NOTE! The content, texts, drawings, pictures and other illustrations are copyright-protected...

 Open the catalog to page 7
Digital Transmitter DTM.OCS.S / DTM.OCS.S/N-8

Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N Introduction 1.8 Registered Trademarks Any brand and product names are registered trademarks of the respective companies and organizations. 1.9 Reference Documentation  MODBUS over Serial Line, Specification & Implementation Guide V1.0 http://www.modbus.org Modbus Standard Library section  MODBUS Application Protocol Specification V1.1 http://www.modbus.org Modbus Standard Library section  STS Website http://www.stssensors.com Datasheets and general product information

 Open the catalog to page 8
Digital Transmitter DTM.OCS.S / DTM.OCS.S/N-9

Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N 2.1 Intended Use The intended use of the Digital Transmitter DTM.OCS.S and DTM.OCS.S/N is the measuring of pressure and temperature and the transmitting of the values in real time to the interface RS485 using Modbus RTU protocol. The use in acids / bases is only possible to a limited extent. Application and medium compatibility must be coordinated with STS before commissioning or when ordering. Only use the device as intended. All information in the operating instructions must be complied with. The operator shall be solely liable for...

 Open the catalog to page 9
Digital Transmitter DTM.OCS.S / DTM.OCS.S/N-10

Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N Product overview Product overview Fig. 1: Product overview Digital Transmitter DTM.OCS.S Operating and safety instructions Digital Transmitter The operating manual can be downloaded from the STS homepage.

 Open the catalog to page 10
Digital Transmitter DTM.OCS.S / DTM.OCS.S/N-11

Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N Commissioning of the Digital Transmitter Commissioning of the Digital Transmitter 4.1 Unpacking The digital transmitter is delivered in product-specific packaging that protects it outstandingly under regular transport conditions. Check the packaging for outward damage. Take out the transmitter carefully and without applying any force. 4.2 Safety Notes CAUTION! Check the values on the rating plate, and particularly the pressure range. These values must correspond to the required technical data. The seals are made of Viton (FPM), unless...

 Open the catalog to page 11
Digital Transmitter DTM.OCS.S / DTM.OCS.S/N-12

Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N Commissioning of the Digital Transmitter NOTE! Some digital transmitters are delivered with a yellow protective cap for the pressure connection. Remove the flap before you use the digital transmitter.  Do not connect the digital transmitter in the direct proximity of motors, pumps, valves, heat sources or other possible interference sources.  Protect the membranes from damage. Do not touch the membranes.  Digital transmitter with cable output: Avoid damage to the cable jacket. Observe the maximum permitted medium temperature of the...

 Open the catalog to page 12
Digital Transmitter DTM.OCS.S / DTM.OCS.S/N-13

Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N Communication with the DTM.OCS.S transmitter Communication with the DTM.OCS.S transmitter 5.1 Summary Communication with the DTM.OCS.S is accomplished via an RS485 serial interface using Modbus protocol transfers at 9600 baud. STS specific, proprietary commands are transmitted as ASCII strings embedded in Modbus compatible data frames. Modbus standard function codes are supported as well. The following settings apply: Type Transmission mode Default address Transmission rate Data bits Stop bits 5.2 Physical interface For communication...

 Open the catalog to page 13
Digital Transmitter DTM.OCS.S / DTM.OCS.S/N-14

Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N Communication with the DTM.OCS.S transmitter 5.3.2 General Modbus message frame structure Message frame: Modbus message (command or response) Modbus PDU Modbus Serial Line PDU Tab. 3: Modbus message frame The number of data words can be derived from the definition of the respective commands. The CRC checksum is divided into two individual bytes with the low byte being transmitted first, followed by the high byte. The CRC checksum is calculated using address, function code and the data words. If the message is faulty (e.g. an invalid...

 Open the catalog to page 14
Digital Transmitter DTM.OCS.S / DTM.OCS.S/N-15

Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N Communication with the DTM.OCS.S transmitter Status message Command has been executed successfully Command execution has been failed The device is busy, try again later Internal error Tab. 5: Status messages For a detailed example please see chapter 5.4.4. 5.4.3 List of STS commands Listed below are the provided STS commands and their associated parameters. Commands may be called with multiple parameters combined. 5.4.3.1 MEASURE The MEASURE command reads out the currently present pressure and temperature. Exemplary answer reads out...

 Open the catalog to page 15

All STS Sensor Technik Sirnach AG catalogs and technical brochures

  1. DL.WMS/GPRS/R

    8  Pages

  2. Accessories

    24  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.