Overview: The document provides detailed technical specifications and features of the ATM/IS Analog Pressure Transmitter, which is FM and FM-C certified. It highlights the benefits, technical specifications, electrical specifications, approvals, qualifications, physical specifications, and ordering information.
Customer Benefits: The pressure transmitter offers FM & FM-C certification, fast customization due to its configurable design, a demountable electrical connector for zero and span adjustments, compact design for minimal space usage, and short response times suitable for dynamic pressure measurements.
Technical Specifications:
  • Pressure Measuring Range: Ranges from 0.1 to 690 bar with varying overpressure and burst pressure limits.
  • Accuracy: Varies from ≤ 0.5% to ≤ 0.1% FS depending on the pressure range.
  • Thermal Shift: Detailed for zero point and span across different temperature ranges.
  • Response Time: Typically less than 1ms for 10-90% FS.
  • Long Term Stability: Ranges from < 0.5% FS to < 0.1% FS depending on the pressure range.
Temperature Range: Operating temperature is -25 to 85°C, process temperature is -40 to 150°C, and storage temperature is -25 to 85°C.
Electrical Specifications:
  • Output Signal: 4 to 20 mA.
  • Power Supply: 10 to 30 VDC.
  • Supply Influence: Less than 0.1% FS.
Approvals and Qualifications: The transmitter is approved under FM 3027351 and FM-C 3027351C. It meets various EN standards for electrostatic discharge, irradiated RF, transients, surge, and conducted RF.
Physical Specifications:
  • Materials: Transducer and housing made from stainless steel or titanium, with seals available in Viton, EPDM, and Kalrez.
  • Accessories: Various cable socket connectors are available for different applications.
Ordering Information: Detailed options for pressure type, measuring range, process connection, electrical connection, output signal, accuracy, temperature range, and additional options like special oil filling and seals.
See more

Catalog excerpts

ATM/IS - Analog Pressure Transmitter-1

Pressure Transmitter - FM / FM-C certified ATM/IS - Analog Pressure Transmitter CUSTOMER BENEFITS • Certificate: FM & FM-C • Fast customization thanks to configurable product design • Demountable electrical connector option allow adjustment of zero and span setting • Compact design requires minimal space • Short response times suitable for dynamic pressure measurements

 Open the catalog to page 1
ATM/IS - Analog Pressure Transmitter-2

Burst pressure, (5) > 200 bar > 200 bar > 200 bar Thermal shift, (± % FS/°C) Zero point 0 ... 70°C < 0.06 < 0.03 < 0.015 Long term stability, (7) < 0.5% FS / < 4 mbar < 0.2% FS / < 4 mbar < 0.1% FS / < 0.2% FS Burst pressure, (5) > 850 / < 1500 bar > 1500 bar Thermal shift, (± % FS/°C) Zero point 0 ... 70°C < 0.015 < 0.015 Response time (typ.) < 1ms / 10 ... 90% FS < 1ms / 10 ... 90% FS Long term stability, (7) < 0.1% FS / < 0.2% FS < 0.1% FS / < 0.2% FS (2) Titanium available < 400 bar (burst pressure > 550 bar) (3) Process connection frontal...

 Open the catalog to page 2
ATM/IS - Analog Pressure Transmitter-3

Power supply Supply influence Circuit diagram EN 61000-4-2 Electrostatic discharge 8 kV contact / 15 kV air EN 61000-4-3 Irradiated RF 10V/m (0.08 ... 2.7 GHz, 3s) Radio sets, wireless phones EN 61000-4-4 Transients (burst) 2 kV Motors, valves EN 61000-4-6 Conducted RF 10 V (0.15 ... 80 MHz, 3 s) Frequency converters (1) Only with optional surge (lightning) protection www.stssensors.com

 Open the catalog to page 3
ATM/IS - Analog Pressure Transmitter-4

Housing Seals Cable Stainless steel (316L / 1.4435), titanium (Gr. 2), (1) Stainless steel (316L / 1.4404), titanium (Gr. 2) Viton (Standard), EPDM, Kalrez PUR, FEP Cable Socket Connector DIN 43650 HART002 Cable socket M16, Binder for absolute and sealed gauge HART009 M16 (Binder 723), IP 67, 12 pins HART049 Cable socket connector HART058 Cable socket connector,

 Open the catalog to page 4
ATM/IS - Analog Pressure Transmitter-5

OPERATING AND SAFETY INSTRUCTIONS Article number

 Open the catalog to page 5
ATM/IS - Analog Pressure Transmitter-7

(4) Process connection available < 600 bar (5) Cable socket connector not included (6) Please specify the required cable length and medium (7) For operating temperature > 50°C, FEP cable must be used (8) Only with pressure connection Fig. 2, Fig. 3, Fig. 4, Fig. 7 and Fig. 8 (16) Connector side not to be used in Zone 0 or Ex ia IIC, explosion risk

 Open the catalog to page 7
ATM/IS - Analog Pressure Transmitter-8

Pressure connections Electrical connections Version for temperature class T4.. ,T6 L = 94 mm for version with surge (lightning) protection L= 121mm for version with surge (lightning) protection socket connector socket connector socket connector Specifications may change without notice. STS Headquarters, Switzerland: STS Sensor Technik Sirnach AG Rutihofstrasse 8 | 8370 Sirnach | Switzerland [email protected] | www.stssensors.com STS Germany: STS Sensoren Transmitter Systeme GmbH Poststrasse 7 | 71063 Sindelfingen | Germany [email protected] | www.stssensors.de STS Great Britain: STS Great...