ATM/F Hygienic Pressure Transmitter
6Pages

{{requestButtons}}

Catalog excerpts

ATM/F Hygienic Pressure Transmitter - 1

Pressure Transmitter ATM/F - Hygienic Pressure Transmitter Customer benefits • Welded and compact design for washdowns without residuals • • Demountable electrical connector option allow adjustment of zero and span setting in the field • Fast customization thanks to modular product design • Short response times suitable for dynamic pressure measurements

Open the catalog to page 1
ATM/F Hygienic Pressure Transmitter - 2

Technical Specifications Pressure measuring range (bar) 0.1 ... 0.5 Accuracy, (2), (± % FS) Thermal shift, (± % FS/°C) Zero point 0 ... 70°C Zero point -25 ... 85°C Span 0 ... 70°C Span -25 ... 85°C Long term stability, (3) (1) Transducer (2) Zero based accuracy according to DIN-16086, incl. hysteresis and repeatability at ambient temperature (3) 1 year (typ. / max.) Temperature range Operating temperature Process temperatur Storage temperatur Power supply Supply influence Current consumption Circuit diagram Load resistance Load influence

Open the catalog to page 2
ATM/F Hygienic Pressure Transmitter - 3

Qualifications Description Electrostatic discharge Radio sets, wireless phones Transients (burst) Motors, valves Frequency converters (1) Only with optional overvoltage protection Physical specifications Materials Transducer Surface roughness of the flush (Ra) Accessories overview Cable Socket Connector DIN43650 Additional documents Operating and safety instructions Article number 10.88.0092 Typical interferences

Open the catalog to page 3
ATM/F Hygienic Pressure Transmitter - 4

Ordering information X. XXXX. XXXX. XX. XXX Type ATM/F Pressure type Gauge Absolute pressure (vacuum) Sealed gauge Pressure measuring range 100 mbar ... 25 bar Process connection Milk flange DN 25 - DIN-11851 (Fig. 1), (1) Electrical connection DIN-43650, with metal threaded part, demountable, IP 65 (Fig. 10), (2) 4 ... 20 mA with overvoltage protection 0 ... 10 VDC with overvoltage protection Accuracy 0 1 2 Temperature range 0 ... 70°C compensated (allowed process temperature: -25 ... 100°C) -25 ... 85°C compensated (allowed process temperature: -25 ... 100°C) -25 ... 85°C compensated...

Open the catalog to page 4
ATM/F Hygienic Pressure Transmitter - 5

Option 2 Electronics packed in gel: Gauge pressure Electronics packed in gel: Absolute pressure Option 3 Seals: Viton (standard) (1) Nut included (2) Cable socket connector not included

Open the catalog to page 5
ATM/F Hygienic Pressure Transmitter - 6

Pressure connection Electrical connections Version for medio temperature op to 100°C L = 90 mm for version with surge (lightning) protection Version for media temperature >100°C up to 150°C L = 125 mm for version with surge (lightning) protection socket connector socket connector socket connector Specifications may change without notice. STS Sensor Technik Sirnach AG Rutihofstrasse 8, 8370 Sirnach, Switzerland 844 Route de la Caille, 74350 Allonzier la Caille, France STS Sensoren Transmitter Systeme GmbH Poststrasse 7, 71063 Sindelfingen, Germany Box 3942 | Warwick | CV34 9AE, United...

Open the catalog to page 6

All STS Sensor Technik Sirnach AG catalogs and technical brochures

  1. Accessories

    24 Pages