Arga Battery Monitor Panel Mount - 1

Arga Battery Monitor Panel Mount Predictive Corrosion Detection ARGA BATTERY MONITOR The Arga Battery Monitor Panel Mount from Electroswitch monitors battery voltage and ground fault detection for DC systems. A LED display identifies alarm conditions in addition to audible alarms. Easily calibrate and set alarm thresholds through the front panel menu. Alarm functions: battery voltage, ground fault detection, AC power loss, ripple voltage, ripple current, high impedance and predictive corrosion detection. Remote monitoring and reporting is ideal for multiple and distant locations. The Arga Battery Monitor Panel Mount supports Serial DNP3.0, Modbus and RS485 communications. Adjustable alarm threshold set points High / low battery voltage alarms ± Ground fault detection with alarm AC charger power loss High accuracy ± 0.2 VDC Open cell / AC charger malfunction alarm Remote Monitoring and Reporting • Serial DNP3.0, Modbus, RS485: 2-wire standard, 4-wire optional • 4 “Form C” dry contact alarm outputs • Analog current outputs (standard 4 to 20 mA) Additional Options Standard Outputs 50–180 VDC, 3VA (for 125 V battery) 100–360 VDC, 5VA (for 250 V battery) 36–72 VDC, 3VA (for 48 V battery) 30.83 KΩ ± 1% from each bus to ground (for 125 V battery) 60.50 KΩ ± 1% from each bus to ground (for 250 V battery) 15 KΩ ± 1% from each bust to ground (for 48 V battery) 0 to ± 199.9 VDC in 0.6" bright red LED digits and decimal point. Accuracy is ± 0.2 VDC (125 VDC model). Alarm relays are Form C contacts Relay 1: + ground fault Relay 2: - ground fault Relay 3: high battery voltage Relay 4: low battery voltage, open battery, loss of AC to charger Digital: DNP3.0, Modbus Analog: 4~20 mA Contact Rating • Optional predictive corrosion detection alarm • Optional handheld ground fault detector · Handheld unit with on / off and volume adjust switch · LED and audible indicators for detected ground faults • Optional 19" rack (consult factory) Battery Input Ground Resistors Voltage Indication Handheld ground fault detector Other Arga Products 25-1000-125A for 125 VDC installations 25-1000-250A for 250 VDC installations 25-1000-48A for 48 VDC installations Standard Part Numbers Single-function digital meters For 19" Rack (single meter) 15-1000-125A-1 for 125 VDC installations 15-1000-250A-1 for 250 VDC installations 15-1000-48A for 48 VDC installations 4.33" W x 4.33” H Portable Battery Monitor Voltage, current and frequency transducers

Open the catalog to page 1

All Storage Battery Systems catalogs and technical brochures

  1. AT10 Series

    12 Pages

  2. SBS-4815CT

    2 Pages