BUILT-IN LOW-ACTION CONTACT TYPE M
8Pages

{{requestButtons}}

Catalog excerpts

BUILT-IN LOW-ACTION CONTACT TYPE M - 1

INTERNATIONAL EXPLANATION OF CONTACT FUNCTIONS STIKO contact Fl CONTACT FUNCTIONS EXPLAINED WITH CLOCKWISE POINTER ROTATION

Open the catalog to page 1
BUILT-IN LOW-ACTION CONTACT TYPE M - 2

* Only possible with one pointer ** M-11 and M-22 / I-11 and I-22 not possible in POD models *** PPC, PCX and PMX-E/G only possible with inductive "INTERVALL" Contact type : I-intervall **** Only possible with stainless steel bourdon tube (0) If liquid filled minimum range 400 mbar x NOT POSSIBLE

Open the catalog to page 2
BUILT-IN LOW-ACTION CONTACT TYPE M - 3

BUILT-IN LOW-ACTION CONTACT TYPE M TYPE M Hz INSTRUMENT MINIMAL RANGE CONNECTOR HYSTERESIS SETPOINT(S) WINDOW POINTER CONTACT POINTER(S) : class 1 : As per page 59 : cable junction box, SEE BELOW : max. 1% up and down : from outside with key : PMMA - plexiglass : black : red ELECTRICAL SWITCH CAPACITY CONTACT TYPE SWITCH FUNCTION CABLE JUNCTION BOX CASE DIMENSIONS *Potential free *Potential free *Potential free *Potential free *Potential free functions to be specified at order functions to be specified at order EXTRA COSTS LIQUID FILLED CASE (ONDINA)

Open the catalog to page 3
BUILT-IN LOW-ACTION CONTACT TYPE M - 4

BUILT-IN INDUCTIVE CONTACT TYPE I INSTRUMENT MINIMAL RANGE CONNECTOR HYSTERESIS SETPOINT(S) WINDOW POINTER CONTACT POINTER(S) : class 1 : As per page 59 : cable junction box, SEE BELOW : max. 1% up and down : from outside with key : PMMA - plexiglass : black : red ELECTRICAL SWITCH CAPACITY Nominal voltage Explosion proof Regulations CONTACT TYPE SWITCH FUNCTION OPERATING CURRENT CASE DIMENSIONS function to be specified at order function to be specified at order function to be specified at order function to be specified at order EXTRA COSTS

Open the catalog to page 4
BUILT-IN LOW-ACTION CONTACT TYPE M - 5

TYPE E Hz INSTRUMENT MINIMAL RANGE CONNECTOR HYSTERESIS SETPOINT(S) WINDOW POINTER CONTACT POINTER(S) : class 1 : As per page 59 : cable junction box, SEE BELOW : max. 1% up and down : from outside with key : PMMA - plexiglass : black : red ELECTRICAL SWITCH CAPACITY Nominal voltage Proximity sensor Output Regulations CONTACT TYPE SWITCH FUNCTION CABLE JUNCTION BOX E-xxx Hz function to be specified with order E-xxxx Hz function to be specified with order CASE DIMENSIONS EXTRA COSTS LIQUID FILLED CASE (ONDINA)

Open the catalog to page 5
BUILT-IN LOW-ACTION CONTACT TYPE M - 6

PRESSURE GAUGE WITH LOW HYSTERESIS BUILT-IN MICROSWITCH TYPE Q MINIMAL RANGE : see page 59 ELECTRICAL CONNECTION : cable junction box : max. 1 % up and down : from outside : PMMA - plexiglass : micro adjustable : first red, (second yellow) HYSTERESIS SETPOINT(S) WINDOW POINTER CONTACT POINTER(S) ELECTRICAL SWITCH CAPACITY Q - 3 Hz* *Potential free SPDT *Potential free DPDT LIQUID FILLING NOT POSSIBLE WITH MICROSWITCH

Open the catalog to page 6
BUILT-IN LOW-ACTION CONTACT TYPE M - 7

ADD-ON UNIT (contact device on top of dial) with PG cable conduit and 1500 mm cable OPTIONS FOR ELECTRICAL CONTACTS BUILT-IN TRANSMITTER DEVICES FOR PRESSURE GAUGES| BUILT-IN EXECUTION (HZ) C.W. CABLE JUNCTIONBOX TYPE

Open the catalog to page 7
BUILT-IN LOW-ACTION CONTACT TYPE M - 8

MODEL PT5 Suitable for following instruments of 0100 mm and 0160mm: Low pressure capsule gauge: type PCX, PMX Differential pressure gauges: type PBD, PDD, PMD, POD Bourdon pressure gauges: type PBX, PBX-SF Pressure gauges with chemical seal: type PBQ, PBS, PBR PBT, PFQ, PFS Thermometers: type TXR, TXC and RTX Transmitter and contacts have no effect on the pointer. Electronics with RF technology and not mechanically driven for both contacts and transmitter. EMC according to EN61326:1998 Accuracy equal for the gauge as for the 4...20 mA transmitter EMC according to EN61326:1998 Power supply 8...

Open the catalog to page 8

All STIKO catalogs and technical brochures

  1. PBX-SS-CD

    13 Pages

  2. PFS-TL

    2 Pages

  3. CHART DRIVES

    3 Pages

  4. PBX-SF

    9 Pages