Safety Network Controller
12Pages

{{requestButtons}}

Catalog excerpts

Safety Network Controller - 1

Safety Network Controller NX Series

Open the catalog to page 1
Safety Network Controller - 2

Safety Network Controller Quick, easy and flexible integration of production line safety Scalable from large automotive production lines to small parts production lines Flexible safety system for large-scale production Interlocking between various machines Quick and easy safety program design Reduce time required for design Reduce time required for verification Efficient safety management and maintenance Minimize system downtime Reduce maintenance work

Open the catalog to page 2
Safety Network Controller - 3

Manufacturers need flexible systems for high-mix production on a global scale. Safety control requirements make these system designs even more complicated. To help reduce design and maintenance time so that manufacturers can efficiently build flexible systems, we offer the NX Safety Network Controller. Safety control for large systems High-speed safety control for mid-size systems Safety over Safety' EtherCAT' Communication Control Unit Safety CPU Unit Machine Automation Controller NX-102 IneW Safety CPU Unit NX-SL5500/5700 |new| SyTiTilC Sllvdio Automation Software Sysmac Studio Ethen...

Open the catalog to page 3
Safety Network Controller - 4

Safety Network Controller Flexible safety system for large-scale production EtherNet/IP for safety across the world Production systems must meet worldwide standards on account of globalization. CIP Safety is a protocol for transmitting safety data via EtherNet/IP that is adopted by factory automation and robot manufacturers all over the world. Using CIP Safety, you can build globally standardized networks and simplify the global procurement of production systems. One connection using CIP Safety Safety systems for industrial robots are gaining popularity. Networks can be easily built with...

Open the catalog to page 4
Safety Network Controller - 5

Standardize the safety system network for a large robot system System configuration In this example, devices and machines communicate via EtherNet/IP and CIP Safety in this system. Each process includes robots, safety light curtains, emergency stop switches, and other safety components. The NX-CSG and NX-SL5 execute safety control programs in each process. CIP Safety is used for safety interlocking between processes and for building a safety control network across the system. PLC ■■■■■■ Hardware cabling * Understand the connection specifications of devices w

Open the catalog to page 5
Safety Network Controller - 6

Safety Network Controller Interlocking between various machines Simple configuration CIP Safety allows safety devices and standard devices to be mixed on the same network, providing safety interlock control between machines. CIP Safety robots and remote I/O terminals can be easily connected. Modular processes bring flexibility to line layouts The NX-CSG320 communication control unit and NX-SL5 Safety CPU Unit exchange interlock signals with other machines while implementing safety control within the machine. Programs for machine control and safety control can be created for each machine....

Open the catalog to page 6
Safety Network Controller - 7

Two different networks in a single system The NX-SL5 Safety CPU Unit connected with the NX102 Machine Automation Controller enables the use of both EtherCAT + FSoE (Safety over EtherCAT) and EtherNet/IP + CIP Safety at the same time. In addition to interlock control within a machine via FSoE, safety interlock between machines can be implemented using CIP Safety. Integrated safety into high-speed machine control (The NX-SL5 Safety CPU Unit combination with the NX102 Machine Automation Controller , provides both safety control and machine control with fast cycle times. By mounting NX-SL5...

Open the catalog to page 7
Safety Network Controller - 8

Safety Network Controller Improve design productivity The Automation Software Sysmac Studio provides various functionalities to reduce time required for production system design and safety program verification. Automatic Programming Online Functional Test Hardware/ software Safety program/ system operation check User-defined Function Block Offline Simulation Reduce time required for production system design Automatic Programming Create a truth table using input, output, and stop conditions of safety devices to automatically produce a safety program for a simple machine. * ‌ Programs created...

Open the catalog to page 8
Safety Network Controller - 9

Implement safety management without experts and global standardization Offline Simulation Programs can be simulated on your PC, Sysmac Studio allows verification of programs without connecting hardware. Online Functional Test enables operation of safety functions to be checked when the NX-SL5 Safety CPU is online with Sysmac Studio. The test results can be output as a report along with the safety signature; the safety signature is displayed on the seven-segment display of the NX-SL5 Safety CPU Unit, and can easily checked if the configuration matches the report after the program has been...

Open the catalog to page 9
Safety Network Controller - 10

Safety Network Controller Maintenance without PC No PC is required for maintenance, which reduces production system maintenance work and minimizes system downtime. Restore, ACR Hardware/ software Safety program/ system operation check Safety Data Logging Minimize system downtime Safety Data Logging An SD card containing logging settings is used for Safety Data Logging. When start trigger conditions are met, the specified device variables and exposed variables can be logged in a chronological order and output to the memory card. This function helps to quickly identify the cause of a sudden...

Open the catalog to page 10
Safety Network Controller - 11

Existing products Choose a safety controller to suit your application. Product name NX Safety Controller Safety Control Unit NX-SL3/SI/SO Integration of safety into machine automation enables simple, flexible system configuration ● ully integrate safety and standard control in one network by connecting F with an NX EtherCAT Coupler Unit ●Safety CPU unit: Up to 128 safety I/O units ● afety input unit: 8 or 4 safety input points per unit S 4-channel units can be directly connected with Omron non-contact switches and single-beam sensors ●Safety output unit: 2 or 4 safety output points per unit...

Open the catalog to page 11
Safety Network Controller - 12

OMRON automation Americas headquarters • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com omron Canada, inc. • head office Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com omron eletronica do brasil ltda • head office Sao Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS DE MEXICO • HEAD OFFICE Mexico DF • 52.55.59.01.43.00 • 01-800-226-6766 • mela@omron.com omron Argentina • sales office Cono Sur • 54.11.4783.5300 OMRON ELECTRONICS DE MEXICO • SALES OFFICE Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com OTHER...

Open the catalog to page 12

All STI catalogs and technical brochures

  1. STI

    5 Pages

Archived catalogs