OSTI Safety Monitoring Relays
22Pages

{{requestButtons}}

Catalog excerpts

OSTI Safety Monitoring Relays - 1

2000 Series (Removable Terminals) >

Open the catalog to page 1
OSTI Safety Monitoring Relays - 2

Does the application require two dual channel inputs? Yes: See Chart Below No: Go to Question 2 Outputs Operating VoltageRelay Safety Aux. Solid State Safety Delayed 24 24 120 200 230 CatalogModel Terminals Inputs > N/O N/C Aux. N/O N/C DC AC AC AC AC PageSafety Monitoring Relays > Does the application require one single channel or one dual channel input? Yes: See Chart Below No: Go to Question 3 Outputs Operating VoltageRelay Safety Aux. Solid State Safety Delayed 24 24 120 200 230 CatalogModel Terminals Inputs > N/O N/C Aux. N/O N/C DC AC AC AC AC PageSafety Monitoring Relays SR101A Fixed...

Open the catalog to page 2
OSTI Safety Monitoring Relays - 3

Does the application require single or dual channel inputs with 2 or 3 delayed safety outputs? Yes: See Chart Below No: Go to Question 5 Outputs Operating VoltageRelay Safety Aux. Solid State Safety Delayed 24 24 120 200 230 CatalogModel Terminals Inputs G9SA-321 > N/O N/C Aux. N/O N/C DC AC AC AC AC PageSafety Monitoring Relays with Delayed Outputs > 1 Fixed 1 N/C, 2 N/C, PNP 3 1 Ɩ 2 ֢׏ ● ● ֢֠ I-5 SR107AD Fixed 1 N/C, 2 N/C, PNP 1 ֖ 3 ֢׏ ● ֖ I-13SR108AD Fixed 1 N/C, 2 N/C, PNP 2 ֖ 2 ֖ ● ● ֖ I-13SR109AD Fixed 1 N/C, 2 N/C, PNP 3 ֖ 1 ֖ ● ● ֖ I-13SR208AD Removable 1 N/C, 2 N/C, PNP 2 ֖ 3 ֖ ●...

Open the catalog to page 3
OSTI Safety Monitoring Relays - 4

Does the application require stop motion sensing or time on-delayӔ after initiation of stop command? Yes: See Chart Below No: Go to Question 8 Outputs Solid State Safety Operating VoltageRelay Safety Aux. Safety Delayed 24 24 120 230 CatalogModel Terminals Inputs > N/O N/C Safety Aux. Delayed N/O N/C DC AC AC AC PageStop Motion Sensing Units 1 N/O SR125SMS Fixed Back EMF 1 N/C Ɩ 2 ֖ ֖ ● ֢׏ ■ I-16SR223SMT Removable Time Delay ֖ 2 ֖ 1 2 ● ● ● ■ I-21 > Does the application require a modular safety system? Yes: See Chart Below No: Go to Question 9 Outputs Solid State Safety Operating...

Open the catalog to page 4
OSTI Safety Monitoring Relays - 5

Safety Inputs: 1 N/C, 2 N/C, PNP Safety Outputs: 3 N/O or 5 N/O Contact Resistance: 100 m 7 Operating Time: 30 ms max. (not including bounce time) > Response Time: 10 ms max. (not including bounce time) Insulation Resistance: 100 M 7 min. (at 500 VDC) Dielectric Strength: Between different outputs: 2,500 VAC, 50/60 Hz for 1 min Vibration Resistance: 10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude) Between inputs and outputs: 2,500 VAC, 50/60 Hz for 1 min Between power inputs and outputs: 2,500 VAC, 50/60 Hz for 1 min Between power inputs and other inputs (only for 100...

Open the catalog to page 5
OSTI Safety Monitoring Relays - 6

G9SX-AD322-/ADA222- G9SX-BC202- G9SX-EX-Overvoltage Category (IEC/EN 60664-1): II II II (Safety relay outputs 13 to 43 > and 14 to 44: III) Operating Time (OFF to ON State): 50 ms max. (Safety input: ON) 50 ms max. (Safety input: ON) 30 ms max. 100 ms max. (Logical AND connection input: ON) Response Time (ON to OFF State): 15 ms max. 15 ms max. 10 ms max. ON-State Residual Voltage: 3.0 V max. (safety output, auxiliary output) OFF-State Leakage Current: 0.1 mA max. (safety output, auxiliary output) Max Wiring Length of Input and Logic AND input: 100 m max. (External connection impedance: 100...

Open the catalog to page 6
OSTI Safety Monitoring Relays - 7

R C US Conforms to EN60204-1, EN954-1, VDE 0113-1 UL and C-UL listed, BG approved Electrical All Models SR101A01 SR101A02 SR101A03 Power Supply: ױ10%, 50-60 Hz 24 VAC/DC 115 VAC 230 VAC Power Consumption: Approx. 1 VA Safety Inputs: 1 N/C (not monitored) > Outputs: 2 N/O Output Rating AC: Inductive AC-15, 4 A/230 V Output Rating DC: Inductive DC-13, 2 A/24 V Min Switched Current/Voltage: 20 mA/24 V Impulse Withstand Voltage: 2500 V Max Drop-Out Time: 75 ms Max Output Fuse: 6 A quick-acting fuse or 4 A slow-acting Reset Mode: Automatic (S11-S21) Contactor Monitoring: N/C loop S11-S21...

Open the catalog to page 7
OSTI Safety Monitoring Relays - 8

R C US Conforms to EN60204-1, EN954-1, VDE 0113-1 UL and C-UL listed, BG approved Electrical All Models SR102AM01 SR102AM02 SR102AM03 Power Supply: 10%, 50-60 Hz 24 VAC/DC 115 VAC 230 VAC > Power Consumption: Approx. 1 VA Safety Inputs: 1 N/C or 2 N/C or 2 solid state (light curtain) Max Input Resistance: 800 7 per channel Outputs: 2 N/O Output Rating AC: Inductive AC-15, 4 A/230 V Output Rating DC: Inductive DC-13, 2 A/24 V Min Switched Current/Voltage: 20 mA/24 V Impulse Withstand Voltage: 2500 V Max Drop-Out Time: 12 ms (75 ms by removing supply voltage) Max Output Fuse: 6 A quick-acting...

Open the catalog to page 8
OSTI Safety Monitoring Relays - 9

R C US Conforms to EN60204-1, EN954-1, VDE 0113-1 UL and C-UL listed, BG approved Electrical All Models SR103AM01 SR103AM02 SR103AM03 Power Supply: 10%, 50-60 Hz 24 VAC/DC 115 VAC 230 VAC Power Consumption: Approx. 1 VA Safety Inputs: 1 N/C or 2 N/C or 2 solid state (light curtain) > Max Input Resistance: 800 7 per channel Outputs: 3 N/O + 1 N/C auxiliary Output Rating AC: Inductive AC-15, 3 A/230 VAC Output Rating DC: Inductive DC-13, 2 A/24 V Min Switched Current/Voltage: 10 mA/10 V Impulse Withstand Voltage: 2500 V Max Drop-Out Time: 12 ms (75 ms by removing supply voltage) Max Output...

Open the catalog to page 9
OSTI Safety Monitoring Relays - 10

R C US Conforms to EN574 Cat. IIIC, EN60204-1, EN954-1, VDE 0113-1 UL and C-UL listed, BG approved Electrical All Models SR104P01 SR104P02 Power Supply: ձ10%, 50-60 Hz 24 VAC/DC 115 VAC > Power Consumption AC: Approx. 2.5 VA Power Consumption DC: Approx. 1.5 W Safety Inputs: 2 x 2 pole (1 N/C + 1 N/O) hand switches Relay Outputs: 2 N/O Max Switched AC: Inductive AC-15, 4 A/230 V Max Switched DC: Inductive DC-13, 2 A/24 V Min Switched Current/Voltage: 20 mA/24 V Impulse Withstand Voltage: 2500 V Max Drop-Out Time: 35 ms (90 ms by removing supply voltage) Max Output Fuse: 6 A quick-acting or...

Open the catalog to page 10
OSTI Safety Monitoring Relays - 11

R C US Conforms to EN60204-1, EN954-1, and VDE 0113-1 UL and C-UL listed, BG approved Electrical All Models SR105E01 SR105E02 SR105E03 Power Supply: 10%, 50-60 Hz 24 VAC/DC 115 VAC 230 VAC Power Consumption: Approx. 1 VA Relay Outputs: 3 N/O + 1 N/C auxiliary monitoring for safety monitoring relay > Output Rating AC: Inductive AC-15, 4 A/230 V Output Rating DC: Inductive DC-13, 2 A/24 V Min Switched Current/Voltage: 20 mA/24 V Impulse Withstand Voltage: 2500 V Max Drop-Out Time: 12 ms (75 ms by removing supply voltage) Max Output Fuse: 6 A quick-acting or 4 A slow-acting MechanicalMounting:...

Open the catalog to page 11