OSTI Perimeter Access Guarding Catalog
6Pages

{{requestButtons}}

Catalog excerpts

OSTI Perimeter Access Guarding Catalog - 1

Selection Guide C-2 Single-Beam Devices BeamSafe > II C-3 Multi-Beam Devices PA4600 C-4 PA4600-BB C-5 Most Popular Models C-6 C-1 >

Open the catalog to page 1
OSTI Perimeter Access Guarding Catalog - 3

PerformanceProtected Height: Single beam Operating Range: 0.3 to 60 m (1 to 200 ft.) Beam Diameter: 31 mm (1.2 in.) Max. Response Time: <0.035 seconds for all models DC Models Input Power: 24 V 10% (negative ground) Receiver/Relay Output: 0.45 A max. Receiver/SS Output: 0.80 A max. Transmitter: 0.17 A max. AC Models Input Power: 100 to 230 VAC ѱ10%, 50/60 Hz Receiver 115 VAC: 16 VA Receiver 230 VAC: 25 VA Transmitter 115 VAC: 10.5 VA Transmitter 230 VAC: 20 VA Effective Aperture Angle: 2.5 maximum half angle Frequency Selection: 4 non-interfering codes, all models Diagnostics: Built-in...

Open the catalog to page 3
OSTI Perimeter Access Guarding Catalog - 4

PerformanceProtective Height: Variable Operating Range: 0.8 to 70 m Response Time: Transmit Code A: <24 ms Transmit Code B: <20 ms Transmit Code C: <16 ms ElectricalInput Voltage (V > in ): 24 VDC ձ 20% Input Power: 8.4 watts (without load on the outputs) Safety Output Ratings: Two PNP outputs sourcing 625 mA max @ V > in . Short circuit protected. Auxiliary Output Ratings: One NPN output sinking 100 mA max @ V > in or one PNP output sourcing 100 mA @ V > in Power Supply: 24 VDC 20%. The rating depends on the current requirements of the loads attached to the outputs. The power supply must...

Open the catalog to page 4
OSTI Perimeter Access Guarding Catalog - 5

PerformanceProtective Height: 500 and 600 mm Operating Range: Safety Output: Two PNP, each output sourcing 625 mA @ 24 VDC, short circuit protected 0.8 to 8 m Response Time: Auxilliary Output: Transmit Code A: <24 ms Transmit Code B: <20 ms Transmit Code C: <16 ms One NPN output sinking 100 mA @ 24 VDC or PNP output sourcing 100 mA @ 24 VDC. Both available in follow or fault operating modes. External Device Monitoring: 50 mA @ 24 VDC steady state Start/Restart: N.O. input. Momentary contact (10 mA consumption) Effective Aperture Angle: ձ 2.5 max., transmitter & receiver at operating range...

Open the catalog to page 5
OSTI Perimeter Access Guarding Catalog - 6

CBL-LCRX-10M Receiver cable, 10 m (32.8 ft) CBL-LCRX-15M Receiver cable, 15 m (49.3 ft.) CBL-LCRX-30M Receiver cable, 30 m (98.5 ft.) PA4600-BB Receiver Cables Transceiver PA46-BB-2-500-A 2 beams w/500 mm (20 in.) spacing PA46-BB-2-600-A 2 beams w/600 mm (24 in.) spacing Passive Mirror Assembly PA46-BB-2-500-P 2 beams w/500 mm (20 in.) spacing PA46-BB-2-600-P 2 beams w/600 mm (24 in.) spacing Transceiver Cable CBL-LCTX-10M Transmitter cable, 10 m (32.8 ft.) CBL-LCTX-15M Transmitter cable, 15 m (49.3 ft.) CBL-LCTX-30M Transmitter cable, 30 m (98.5 ft.) CBL-LCRX-10M Transceiver cable, 10 m...