Catalog excerpts

© IO-Link SMART SENSOR CSS 014 | IO link parameters
Open the catalog to page 1
SMART SENSOR CSS 014 | IO link parameters GENERAL INFORMATION GENERAL DATA Manufacturer name Manufacturer ID Manufacturer URL Product ID Device ID IO link version Bitrate Minimum cycle time SIO mode Data storage STEGO Elektrotechnik GmbH 0x04C6 / 1222d www.stego.de CSS 01411.2-00 ID 0x000012 / 18d V 1.1 COM2 10.0 ms No Yes IDENTIFICATION Parameter name Vendor Text Manufacturer text 0x11 0x00 StringT [ 64 ] www.stego.de Product Name Device name 0x12 0000 StringT [ 64 ] CSS 014 IO link Product ID ID number of the device 0x13 0000 StringT [ 64 ] CSS 01411.2-xx Product Text Device description...
Open the catalog to page 2
Humidity Alarm High Humidity status, alarm H 1.x 0x0B 0x00 BooleanT false, true Humidity Range High Humidity status, warning H 2.x 0x0C 0x01 BooleanT false, true Humidity Range Low Humidity status, warning H 3.x 0x0D 0x02 BooleanT false, true Humidity Alarm Low Humidity status, alarm H 4.x 0x0E 0x03 BooleanT false, true SMART SENSOR CSS 014 | IO link parameters Temperature Current sensor measurement value (factor for 0x01 0x20 IntegerT_16 °C/°F calculating the display value: 0.1) Temperature Alarm High Temperature status, alarm T 1.x 0x02 0x18 BooleanT false, true Temperature Range High...
Open the catalog to page 3
SMART SENSOR CSS 014 | IO link parameters PARAMETERS The parameters for the alarm and warning limits are deactivated when the device is in its delivered condition (factory setting). These parameters can be overwritten by the user. Customer-specific parameter assignment is therefore possible. The sensor outputs the data as raw data (IO link values). However, the parameters in the IO link tool are input directly as a value in °C / °F. The factor for calculating the display value for temperature and humidity is 0.1. The parameters for temperature and humidity are checked in terms of their...
Open the catalog to page 4
SMART SENSOR CSS 014 | IO link parameters status bit is set in the process data. Calculation of the display value for the humidity 17/09/2019, V1.0 | Subject to technical changes. We provide no assurances as to the accuracy of the specifications. The information cited does not absolve the customer from its responsibility for independent application checks. www.stego.de
Open the catalog to page 5
SMART SENSOR CSS 014 | IO link parameters DIAGNOSTICS DATA Parameter name Device is OK Maintenance required Out of specification Functional check Failure Detailed Device Status Detailed Device Status [1] Detailed Device Status [2] Detailed Device Status [3] Detailed Device Status [4] Detailed Device Status [5] Detailed Device Status [6] Error Count Operating Hours Power-on counter Additional device-dependent information (errors/warnings/messages) Output of errors/warnings/messages Error counter Operating hours counter (base unit 0.001 h) Activation counter See „Events und Meldungen“ auf...
Open the catalog to page 6
SMART SENSOR CSS 014 | IO link parameters HUMIDITY DIAGNOSTICS DATA Parameter name Minimum humidity across the entire activation period Event counter for humidity exceeded alarm quantity Event counter for humidity range exceeded quantity Event counter for humidity range undershot quantity Event counter for humidity undershot alarm quantity Duration of incidences in the humidity range 0% to 100% in 20x 5% humidity range steps 17/09/2019, V1.0 | Subject to technical changes. We provide no assurances as to the accuracy of the specifications. The information cited does not absolve the customer...
Open the catalog to page 7
SMART SENSOR CSS 014 | IO link parameters EVENTS AND MESSAGESThe messages are output via the variable Detailed Device Status [x] (see „Diagnosedaten“ auf Seite 6). Name Sensor Humidity raw data Raw data above the value for the calculation of 100.0% false/true Error 6215 Humidity Points: Preset 1 Preset 1 is loaded to the humidity parameters 17/09/2019, V1.0 | Subject to technical changes. We provide no assurances as to the accuracy of the specifications. The information cited does not absolve the customer from its responsibility for independent application checks. www.stego.de
Open the catalog to page 8All STEGO catalogs and technical brochures
-
Datasheet ESS 076
1 Pages
-
STEGO-Catalogue_EN_2023-2024
61 Pages
-
LOOP-Heaters
8 Pages
-
Sensor Hub SHC 071
4 Pages
-
Actuator Hub AHC 072
1 Pages
-
Whitepaper STEGO-CONNECT English
11 Pages
-
The new FILTER FAN PLUS
6 Pages