video corpo

BATTENLOK® HS

BATTENLOK® HS

BATTENLOK® HS

Product catalog summary
Product Overview:
BattenLok® HS is a high-strength structural standing seam metal roofing system. It features a 2-inch tall vertical seam and is available in 12-inch and 16-inch widths. The system can be installed over purlins or bar joists and does not require a solid substructure.

Specifications:
  • Applications: Roof
  • Coverage Widths: 12", 16"
  • Minimum Slope: ½:12
  • Panel Attachment: Concealed Fastening System
  • Gauges: 24 (standard), 22 (optional)
  • Finishes: Smooth or Embossed, with Striations or Pencil Ribs
  • Coatings: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic

Features and Benefits:
  • Low and high clips for various insulation thicknesses
  • Heavier gauges and embossing minimize oil canning
  • UL 580, UL 790 Class A, UL 263, and UL 2218 Class 4 ratings
  • Florida approval rating

Environmental and Structural Performance:
  • Air-leakage: 0.016 cfm/ft² at 1.57 psf, 0.025 cfm/ft² at 6.24 psf
  • Water Penetration: No uncontrolled penetration at 20.00 psf
  • Impact Resistance: Class 4 Rating
  • Fire Resistance: UL 790 Class A, UL 263
  • Uplift Resistance: AISI S100
  • Gravity Loads: AISI S100

Roof Listings:
  • FM Global: Class 90 Rating
  • Underwriters Laboratories: Various standards including ASTM E 1592, FM 4471, UL 790
  • Florida Product Approval: Compliance with Florida Building Code
  • Miami-Dade County: Windstorm and hail insurance coverage in Texas coastal counties
See more

Catalog excerpts

BATTENLOK® HS-1

STANDING SEAM METAL ROOFING BATTENLOK® HS BattenLok® HS is a mechanically field seamed, high strength structural standing seam roof system. The panels have a 2” tall vertical seam and are available in both 12-inch and 16-inch widths. BattenLok® HS can be installed directly over purlins or bar joists, is capable of transitioning from roof to fascia and does not require a solid substructure for support. FEATURES AND BENEFITS Low and high clips are available to allow for various thicknesses of insulation to be installed between the panels and purlins. Heavier gauges, striations, embossing and installation over a solid deck minimize oil canning. Striated with Pencil Ribs Numerous UL 580 Construction rating are available, as well as UL 790, Class A for external fire, numerous roof assemblies for UL 263 for internal fire and the UL 2218 Class 4 impact rating. BattenLok® HS carries Florida approval rating. PRODUCT SPECIFICATIONS APPLICATIONS: Roof COVERAGE WIDTHS: 12", 16" MINIMUM SLOPE: ½:12 PANEL ATTACHMENT: Concealed Fastening System; Low, High (fixed or floating), Utility (no insulation clearance) GAUGES: 24 (standard); 22 (optional) FINISHES: Smooth or Embossed; with Striations or Striations and Pencil Ribs COATINGS: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic

 Open the catalog to page 1
BATTENLOK® HS-2

STANDING SEAM METAL ROOFING TEST METHOD PURPOSE Air-leakage Through Roof Panel Joints Determines the air leakage characteristics of metal roof panels under specified air pressure differences at ambient conditions 0.016 cfm/ft2 at 1.57 psf static pressure 0.025 cfm/ft2 at 6.24 psf static pressure Water Penetration Through Roof Panel Joints Determines the resistance to water penetration of metal roof panels under uniform static air pressure difference No uncontrolled water penetration through the panel joints at a static pressure of 20.00 psf Impact Resistance Determines Impact Resistance of prepared...

 Open the catalog to page 2

All Star Building Systems catalogs and technical brochures

  1. SUPERLOK®

    2  Pages

  2. DOUBLE-LOK®

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.