Catalog excerpts

AvCount Lube Particle Counter Seta AvCount Lube Pressurised Light Extinction Particle Counter ASTM D7647*; ISO 4406*; ISO 60970*; ASTM D6786; NAS 1638; AS 4059F; IP 565; ISO 11171; ISO 11500; SAE A6D; SAE 749D; GOST 17216; GB 5930; GJB 420-A-1996; GJB 4208-2006; JIS B 9932:2012; JIS B 9933:2021; JIS B 9934:2012 *Does not require connection to a computer • Cumulative Particles/ml • ISO Cleanliness Codes • Up to 200 mm2/s viscosity • 4µm(b) to >100µm(b) • Simple operation • High visibility screen • Integral compressor • 250ml sample bottles • PC controlled or stand-alone • Programmable via PC AvCount Lube is a pressurised laser based particle counter used for determining the particle concentration in oils with a viscosity up to 200 mm2/s. It can be used throughout the distribution network and in the laboratory. In fact anywhere that requires accurate determination of particle distribution in a liquid sample. Whether checking the quality of in service lubricants, hydraulic fluids or, insulating oils, AvCount Lube provides fast and precise results. Integral Compressor AvCount Lube comprises a light extinction automatic particle counter and a pressure delivery unit. Designed to handle samples with a viscosity up to 200 mm2/s, the AvCount Lube has an integral compressor that pressurises the sample chamber to 3 barG. Safety features include a mechanical interlock that releases the pressure before the sample chamber can be opened, a compressor stop button that automatically releases the pressure and a mechanical pressure relief valve. The operator can create or edit test methods on a PC or laptop. Particle sizes, flushing volume, number of measurements, number of repeats and alarm threshold levels can all be programmed. Up to three ISO 4406 based test methods can be uploaded into the AvCount Lube memory via the USB port. The factory default methods are ASTM D7647 (lubricants), ISO 60970 (insulating oils) and a basic ISO 4406 (hydraulic oils and general purpose). Computer or Stand-alone Operation AvCount Lube is operated via a personal computer using the supplied ProTrend software. It supports multiple test methods and cleanliness code systems, including ISO 4406 and NAS 1638. It also allows the creation of custom test methods. The graphical interface displays results for up to 15 size bands and can plot trend analysis for each size band over time. Data can be exported into spreadsheets. In stand-alone mode, AvCount Lube supports ISO 4406 based test methods. Operation is via a turn and push control and simple menu system. Test progress and results for up to 6 size bands are displayed on the high visibility screen. Results are saved and indexed by date and time. For tests that require repeat measurements (i.e. ASTM D7647), the results for each size band are automatically averaged. Calibration & Verification AvCount Lube utilises 16 point calibration. Calibration can be carried out either using NIST traceable standard solutions or by interfacing with a primary calibrated ‘Master’ AvCount Lube. The calibration can be carried out at a user site or at our authorised regional laboratories. A number of calibration curves, based on different standards, can be saved onto a PC and uploaded to the AvCount Lube when required. Operators are able to verify their AvCount Lube using the AvCount Verification Material (SA1006-0). The material is a suspension of a NIST traceable medium test dust in a super-clean clear, mineral based, hydraulic oil. Stanhope-Seta, London Street, Chertsey, Surrey, KT16 8AP, UK t: +44 (0) 1932 564391 | e: sales@stanhope-seta.co.uk | w
Open the catalog to page 1
AvCount Lube Particle Counter Software There are two programmes that can be used with AvCount Lube. ProTrend - Allows an operator to control an AvCount Lube from a personal computer or laptop. It allows the operator to create new or edit existing test methods, run tests or display results. The progress of tests and their results are displayed on the computer screen. Results saved in the AvCount Lube memory can be viewed directly or downloaded to the computer. ProTrend can be used to upload up to three ISO 4406 based test methods to the AvCount Lube for stand-alone operation. Calibration -...
Open the catalog to page 2All Stanhope-Seta catalogs and technical brochures
-
Seta Existent Gum Solid Bath
1 Pages
-
SSAFCON Sampler 16160-2
1 Pages
-
Seta AvCount3 SA1100-0
4 Pages
-
Seta AvCount Lite SA1800-2
2 Pages
-
FIJI
4 Pages
-
Seta Universal Penetrometer
1 Pages
-
Water Washout Tester 19610-4
1 Pages
-
Four Ball Lubricant Tester
3 Pages
-
SetaVap2 81000-2
4 Pages
-
SetaVap4 80600-0
4 Pages
-
KV-6 Viscometer Bath 84200-3
2 Pages
-
Seta PM-93 35000-0
4 Pages
-
Seta Block Heater
1 Pages
-
Seta Oil Test Centrifuge
2 Pages