Product catalog summary
Overview
The SR715 and SR720 LCR Meters by Stanford Research Systems are precision instruments designed for measuring passive components with high accuracy. The SR715 offers a basic accuracy of 0.2%, while the SR720 provides 0.05% accuracy. These meters are suitable for applications such as incoming inspection, quality control, automated testing, and general benchtop use.

Specifications
- Accuracy: SR715: 0.2%, SR720: 0.05%
- Display: 5-digit LED for L, C, R, Q, or D
- Test Frequencies: Up to 100 kHz (SR720)
- Measurement Rate: Up to 20 measurements per second
- Interfaces: RS-232, GPIB (SR720), Parts Handler
- External Bias: Up to 40 VDC

Features
- Measurement Modes: Auto, R+Q, L+Q, C+D, C+R
- Equivalent Circuit Models: Series or parallel
- Calibration: Automatic null calibration for open and short circuits
- Binning: Supports pass/fail, overlapping, and sequential binning schemes
- Test Fixtures: Kelvin fixture for radial and axial components, optional SMD tweezers and Kelvin clips

Operation
The meters are user-friendly with an AUTO measurement mode that simplifies setup. Up to nine instrument setups can be stored for quick recall. The null calibration procedure compensates for lead impedance and stray capacitance.

Measurement Capabilities
- R + Q Mode: R: 0.0001 Ω to 2000 MΩ, Q: 0.00001 to 50
- L + Q Mode: L: 0.0001 µH to 99999 H, Q: 0.00001 to 50
- C + D Mode: C: 0.0001 pF to 99999 µF, D: 0.00001 to 10
- C + R Mode: C: 0.0001 pF to 99999 µF, R: 0.00001 Ω to 99999 kΩ

Ordering Information
- SR715: $1295
- SR720: $1495
- SR726 Kelvin Clips: $500
- SR727 Surface Mount Tweezers: $300
- SR728 4-wire BNC Adapter: $300

Conclusion
The SR715 and SR720 LCR Meters are versatile and precise tools for measuring a wide range of passive components, offering features that support efficient testing and sorting in various industrial and laboratory settings.
See more

Catalog excerpts

SR715/720-1

LCR MetersSR715 and SR720 — LCR meters with test frequencies to 100 kHz • 0.05 % basic accuracy (SR720), 0.2 % (SR715) • 5-digit display of L, C, R and Q or D • Test frequencies to 100 kHz (SR720) • Up to 20 measurements per second • Binning and limits for parts sorting • External capacitor bias up to 40 V • RS-232 computer interface • GPIB & Parts Handler interfaces (SR720) • SR715... $1295 (U.S. list) • SR720... $1495 (U.S. list) The SR715 and SR720 LCR Meters measure passive components with as little as 0.05 % error. These easy-to-use instruments are quick to setup, adjust and calibrate. The SR715 and SR720 are ideal for applications such as incoming inspection, quality control, automated test, and general benchtop use. Front-Panel Display A 5-digit LED display shows measured values, entered parameters, instrument status, and user messages. When making measurements, the major parameter (L, C or R) is shown on the left display and the appropriate minor parameter (Q, D or R) is shown on the right display. Making Measurements Measurements can be performed at test frequencies of 100 Hz, 120 Hz, 1 kHz, 10 kHz and 100 kHz (SR720 only). A built-in drive voltage can be set to preset values (0.1, 0.25 and 1.0 V) or adjusted from 0.1 to 1.0 V in 50 mV increments. Measurements are taken at rates of 2, 10 or 20 samples per second. Consecutive readings can be averaged between two and ten times for increased accuracy. Both series or parallel equivalent circuit models of a component are supported. Capacitor measurements use either the internal 2.0 VDC bias or an external source of up to 40 VDC. 5RS Stanford Research Systems

 Open the catalog to page 1
SR715/720-2

Simple to Operate The power and flexibility of the SR715/720 does not come at the expense of ease-of-use. A convenient AUTO measurement mode automates the selection of setup parameters and quickly determines the appropriate device model for whatever component is being measured. Up to nine instrument setups can be stored in non-volatile memory for quick recall at a later time. progressively larger bins (e.g., ±1 %, ±2 %, ±3 %). Sequential bins can have different nominal values, each separated by a percentage or a nominal value and asymmetrical limits. Binning parameters are also easily stored...

 Open the catalog to page 2
SR715/720-3

Measurement modes Equivalent circuit Parameters displayed Basic accuracy Measurement Range (R+Q mode) R Q (L + Q mode) L Q (C + D mode) C D (C + R mode) C R Electrical Test frequency Auto, R+Q, L+Q, C+D, C+R Series or parallel Value, Deviation, % Deviation or Bin Number (Deviation and % Deviation are calculated relative to a stored value.) SR715: 0.2 %, SR720: 0.05 % Fixture Fixture Fixture protection 4-wire kelvin fixture for radial leaded parts with adapters for axial leaded parts. Protected up to 1 Joule of stored energy and 200 VDC (for charged capacitors). Fused at 0.25 A output current...

 Open the catalog to page 3

All Stanford Research Systems catalogs and technical brochures

  1. SR556

    1  Page

  2. QMSc

    3  Pages

  3. FS730/1

    4  Pages

  4. SC10

    2  Pages

  5. PRS10

    4  Pages

  6. CG635

    5  Pages

  7. PERF10

    2  Pages

  8. SR620

    4  Pages

  9. LCR Meters

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.