3kW-10kW Planar Transformers | Size 560
4Pages

{{requestButtons}}

Catalog excerpts

3kW-10kW Planar Transformers | Size 560 - 1

SOLUTIONS | Planar Transformers & Inductors SIZE 560 3kW-10kW DESIGN EXAMPLE TRANSFORMER DESIGN | EXAMPLE - PQC1901 (U.S. PAT. 7,460,002) ui z o !< LJ LL-LJ LU CL cn —1 < lj a: i— LJ LU —I LU Topology Half Bridge ZVS Output Voltage/Current After Rectification 6144W Max. (24VDC/256A) Turns Ratio - Np/Ns 20T/1T + 1T Efficiency At Full Power (Calculated) 99.24% (47W Losses) Ambient Temp. Max. (Transfer clamped to heatsink) +85°C *Heatsink Provided By Customer Temperature Rise Hot Spot Heatsink, Max.* +37.6°C Minimum Isolation Voltage Primary To Secondary And Core 3000VDC Leakage Inductance 1-2/3-4-5 Shorted, Typ. 3pH NOTES: 1) FOR OPTIMAL PERFORMANCE A THERMALLY CONDUCTIVE SUBSTRATE BETWEEN FERRITE AND HEATSINK SHOULD BE UTILIZED 2) PATENTED TERMINALS AVAILABLE FOR SPLITTING HIGH CURRENT WINDING 3) CUSTOM TERMINALS CAN BE DESIGNED AND OPTIMIZED

Open the catalog to page 1
3kW-10kW Planar Transformers | Size 560 - 2

SOLUTIONS | Planar Transformers & Inductors TRANSFORMER DESIGN | EXAMPLE - PQC2123 SIZE 560 3kW-10kW DESIGN EXAMPLE ELECTRICAL SPECIFICATIONS Topology Full Bridge ZVT Output Voltage/Current After Rectification 12kW max. (500VDC/24ADC) Output Voltage/Current After Rectification 28.4VDC/83A, 100A Surge Turns Ratio - Np/Ns 15T/10T Duty Cycle At Low Input Voltage Max. 99.0% Efficiency At Full Power (Calculated) 99.3% (87.4W Losses) External Heatsink Temperature Max. +45°C Temp. Rise Hot Spot External Heatsink1, Max. +69.9°C Minimum Isolation Voltage Primary To Secondary And Core 5700VAC for...

Open the catalog to page 2
3kW-10kW Planar Transformers | Size 560 - 3

SOLUTIONS | Planar Transformers & Inductors TRANSFORMER DESIGN | EXAMPLE - PQC2116 co z o Topology Full Bridge ZVS Input Voltage Np1 = 12 Turns (1-2) 350-630VDC Input Voltage Np2 = 16 Turns (1-3) 500-820VDC Output Voltage/Current After Rectification 28VDC/250A (7kW) Efficiency At Full Power (Calculated) 99.2% (55W losses) External Heatsink Temperature Max. +65°C *Transformer Clamped To Heatsink Temp. Rise Hot Spot External Heatsink*, Max. +44°C Minimum Isolation Voltage Primary To Secondary And Core 2700VAC Primary Resistance, Rdc, Np,1 (1-2)/Np2 (1-3), Max. 14/18mOhm Secondary Resistance,...

Open the catalog to page 3
3kW-10kW Planar Transformers | Size 560 - 4

SOLUTIONS | Planar Transformers & Inductors INDUCTOR DESIGN | EXAMPLE - PQC2112 (U.S. PAT. 7, 460,002) SIZE 560 3kW-10kW DESIGN EXAMPLE ELECTRICAL SPECIFICATIONS Inductance At Rated Current 100pH ±10% Rated Current (Ave. ±12.5A Ripple) 32ADC +3App Minimum Isolation Voltage (Winding To Core) 2500VDC Temp. Rise Hot Spot Baseplate, Max. +46°C Total Losses At Max. Current 28.7W NOTES: 1) FOR OPTIMAL PERFORMANCE A THERMALLY CONDUCTIVE SUBSTRATE BETWEEN FERRITE AND HEATSINK SHOULD BE UTILIZED 2) PATENTED TERMINALS AVAILABLE FOR SPLITTING HIGH CURRENT WINDING 3) CUSTOM TERMINALS CAN BE DESIGNED...

Open the catalog to page 4