SOLUTIONS | Planar Transformers & Inductors folfoK STANDEX ELECTRONICS PQC2066 P135 (Date Code) TRANSFORMER DESIGN | EXAMPLE - PQC2066 ELECTRICAL SPECIFICATIONS Topology Input Voltage Output Voltage/Current After Rectification Turns Ratio - Np/Nboost/Ns Switching Frequency Duty Cycle, Max. At Low Input Voltage Efficiency At Full Power Calculated External Ambient Temp, Max. Temp. Rise, Hotspot Ambient, Max. +58°C Minimum Isolation Voltage Primary To Secondary 2121VDC Leakage Inductance 1-2/3-4 Shorted, Typ. 50nH NOTES: 1) FOR OPTIMAL PERFORMANCE A THERMALLY CONDUCTIVE SUBSTRATE BETWEEN FERRITE AND HEATSINK SHOULD BE UTILIZED 2) HEATSINK & THERMAL SOLUTIONS AVAILABLE