1. Catalogs
  2. StandexMeder Electronics GmbH
  3. 2kW-6kW Planar Transformers | Size 350

2kW-6kW Planar Transformers | Size 350
1 /3Pages

2kW-6kW Planar Transformers | Size 350

2kW-6kW Planar Transformers | Size 350
1 /3Pages

Catalog excerpts

2kW-6kW Planar Transformers | Size 350-1

SOLUTIONS | Planar Transformers & Inductors SIZE 3502kW-6kW DESIGN EXAMPLE 2T TRANSFORMER DESIGN | EXAMPLE - PQC1954 (U.S. PAT. 7,460,002) ELECTRICAL SPECIFICATIONS Topology Full Bridge ZVS Output Voltage/Current After Rectification 2.5kW typ. 3kW surge Output Voltage/Current After Rectification 28.4VDC/83A, 100A surge Turns Ratio - Np/Ns 16/2+2T Duty Cycle At Low Input 80.0% Efficiency At Full Power (Calculated) 99.1% (21W losses) Mounted On Heatsink With Max. Temp. +90°C Temp. Rise Hot Spot Baseplate, Max. +21°C Minimum Isolation Voltage Primary To Secondary And Core 2500VAC for 1min Secondary Resistance, Rdc, Ns, Max. ImOhm (0.5+0.5mOhm) Leakage Inductance 1-2/3-4-5 Shorted, Typ. 1.5pH Weight Range 150-400grams NOTES: 1) FOR OPTIMAL PERFORMANCE A THERMALLY CONDUCTIVE SUBSTRATE BETWEEN FERRITE AND HEATSINK SHOULD BE UTILIZED 2) PATENTED TERMINALS AVAILABLE FOR SPLITTING HIGH CURRENT WINDING

 Open the catalog to page 1
2kW-6kW Planar Transformers | Size 350-2

SOLUTIONS | Planar Transformers & Inductors SIZE 350 2kW-6kW DESIGN EXAMPLE TRANSFORMER DESIGN | EXAMPLE - PQC2014 ui z o !< LJ LL-LJ LU CL cn —1 < lj a: i— LJ LD —I LU Topology Full Bridge ZVS Output Voltage/Current After Rectification 3100VDC/0.5A (1.55kW max) Efficiency At Full Power (Calculated) 99.3% (11W losses) Airflow Temperature, Speed (Recommended) 50CFM Temp. Rise Hot Spot Heatsink, Max. +53°C Minimum Isolation Voltage Primary To Core 500VAC Secondary To Primary And Core 3000VDC Leakage Inductance 1-2/3-4-5 Shorted, Typ. 0.2pH NOTES: 1) FOR OPTIMAL PERFORMANCE A THERMALLY CONDUCTIVE...

 Open the catalog to page 2
2kW-6kW Planar Transformers | Size 350-3

SOLUTIONS | Planar Transformers & Inductors SIZE 350 2kW-6kW DESIGN EXAMPLE INDUCTOR DESIGN | EXAMPLE - PQC2136 ELECTRICAL SPECIFICATIONS Inductance At Rated Current Rated Current (Ave. ±12.5A Ripple) Ripple Frequency 0.5pH ±3% Temp. Rise Hot Spot Baseplate (Heatsink Cooling), Max. +40°C : UTILIZED 2) PATENTED TERMINALS AVAILABLE FOR SPLITTING HIGH 200kHz Resistance Max. 0.2mOhm CURRENT WINDING Minimum Isolation Voltage (Winding To Core) 500VDC Total Losses

 Open the catalog to page 3

All StandexMeder Electronics GmbH catalogs and technical brochures

  1. Switch Green

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.