Formula for Leak Powder Quantities:
To calculate the total square footage of filter cloth area, use the formula: diameter of bag x 3.14 x length of bag x quantity of bags / 144. For the leak detection test, 1 lb. of leak detection powder is required per 1000 sq ft of filter cloth area.
Purpose of Leak Detection Powder:
The powder helps identify leaks in baghouses by being injected into the baghouse inlet. It travels through the system and highlights leaking areas under a black light with bright colored markings.
Available Colors:
Leak detection powders are available in yellow, pink, green, and orange.
Contact Information:Inside USA: Toll-Free 1.800.634.5837
Outside USA: 760.929.8559
Website:
www.standardfilter.comAddress: Standard Filter Corporation, 5928 Balfour Court, Carlsbad, California USA
Phone: 760.929.8559
Fax: 760.929.1901
Email: