REP Centralised electrical connections - 2

Centralised, ergonomic...

Open the catalog to page 2
REP Centralised electrical connections - 3

Registered Community Design ... and reliable connections Ergonomics Easy  wiring Easy connection and increased lifespan Connection without any risk of error: harness outlet straight or 90°, of the contacts thanks to the guiding harnesses connected using PG, NPT only one possible connection position for plates, REP multi-couplings designed for many or metric female thread coupling. indexed housings on the plates and inserts in the housings, Fast and easy locking by simply rotating the control lever by a half turn. housings are protected against dust and liquid splashes: protection rating IP...

Open the catalog to page 3
REP Centralised electrical connections - 4

3 standard sizes depending on the number of circuits to connect REP 103 Model 2 connectors * Very compact. To connect up to 74 contacts in just one movement in a confined space. * also available in model 1 connector To connect up to 111 contacts in just one movement To connect up to 148 contacts in just one movement

Open the catalog to page 4
REP Centralised electrical connections - 5

All plates are available in 2 configurations Configuration 1 Power supply on mobile plate side Power supply on fixed plate side POWER SUPPLY Mobile plate fitted with housings and male inserts Mobile plate fitted with housings and female inserts Fixed plate fitted with housings and female inserts Fixed plate fitted with housings and male inserts POWER SUPPLY For totally safe handling, the female contacts must always be fitted on the side of the power supply. Different types of inserts 3 types of connections for electrical harnesses From 2 to 36 contacts + earthing. Standard silver plated....

Open the catalog to page 5
REP Centralised electrical connections - 6

VERY COMPREHENSIVE AND MODULAR RANGE Options Integrated into the product upon order: see corresponding codes on pages 9 to 11. All options can be used together. Safety locking system Reversed control lever Proximity sensors This safety device, which automatically This option makes it possible for moulds Controls "connected" and "disconnected" engages during connection, prevents any with many circuits, to install 2 multi- plates from accidental disconnection, couplings side by side in a small space even if the locking handle is knocked. To whilst keeping the same direction of use Wire...

Open the catalog to page 6
REP Centralised electrical connections - 7

Additional equipment to be ordered separately: see part numbers on page 13. Foolproof keying system Parking plate Carrying handle Enables all connection errors to be equipped with a locking system for For even easier handling. avoided when using several plates on the storage of the plate when not in use. same mould. Parking plate can be fitted with a proximity sensor (as an option). Protective cap for housings Ensures protected against external aggressions, contamination and damage when storing the moulds. Parking plate Foolproof keying system Protective caps Carrying handle

Open the catalog to page 7
REP Centralised electrical connections - 8

Derating curves Contacts: 1.5 / 2 mm Connection: 0.75 / 1 mm2

Open the catalog to page 8
REP Centralised electrical connections - 9

Part numbers REP 103.02 - Model 2 connectors Side Mobile plate Part numbers for mobile plates fitted with 2 female housings Part numbers for mobile plates fitted with 2 male housings Power supply side Receiver side female insert * male insert * Part numbers for fixed plates fitted with 2 male housings Part numbers for fixed plates fitted with 2 female housings Receiver side Power supply side Fixed plate male insert * female insert * Additional equipment Add the corresponding option codes to the part numbers above: Plates are fitted with standard housings and Nitrile (NBR) seals. Housings...

Open the catalog to page 9
REP Centralised electrical connections - 10

Part numbers REP 203.03 - Model 3 connectors Side Mobile plate Part numbers for mobile plates fitted with 3 female housings Part numbers for mobile plates fitted with 3 male housings Power supply side Receiver side female insert * male insert * Part numbers for fixed plates fitted with 3 male housings Part numbers for fixed plates fitted with 3 female housings Receiver side Power supply side Fixed plate male insert * female insert *

Open the catalog to page 10
REP Centralised electrical connections - 11

REP 203.04 - Model 4 connectors Side Mobile plate Part numbers for mobile plates fitted with 4 female housings Part numbers for mobile plates fitted with 4 male housings Power supply side Receiver side female insert * male insert * Part numbers for fixed plates fitted with 4 male housings Part numbers for fixed plates fitted with 4 female housings Receiver side Power supply side Fixed plate male insert * female insert * Additional equipment Add the corresponding option codes to the part numbers Plates are fitted with standard housings and Nitrile (NBR) seals. Housings are also available on...

Open the catalog to page 11
REP Centralised electrical connections - 12

Part numbers Inserts Part numbers Current   for each contact   in operation (A) 135 (per contact) 110 (per contact) 80 (per contact) 135 (per contact) 150 (per contact) 63 (per contact) 90 (per contact) 63 (per contact) 50 (per contact) Wire section of connection (mm2) Male inserts Female inserts Male inserts Female inserts * Silicone inserts For more choices,+please view our brochure "Connectors for multi-couplings" (size G3 only). 36 PE 36 + PE 36 + PE Tools for crimping contacts 36 + PE Wire section   of connection (mm2) Part number Delivered with 5 crimp anvils Tools for assembling and...

Open the catalog to page 12
REP Centralised electrical connections - 13

Additional equipment part numbers Foolproof keying kits Parking plates Models Part numbers Proximity sensor option: add /DP code to the part-number. mobile plate fixed plate fixed plate Kits part numbers mobile plate Carrying handle Protective caps for housing Part numbers Female housing Male housing Part number Delivered with washers and fixing screws For optimal use of your multi-connection plates Stäubli offers, on simple request, drawings containing detailed information about assembly, circuit wiring, keying kit and sensors assembly as well as all the other options and additional...

Open the catalog to page 13
REP Centralised electrical connections - 14

Dimensioning plans REP 103.02 Configuration 1 Mobile plate fitted with female connectors Fixed plate fitted with male connectors Mobile plate fitted with male connectors Fixed plate fitted with female connectors View from above Mobile plate fitted with female connectors Fixed plate fitted with male connectors Mobile plate fitted with male connectors Fixed plate fitted with female connectors View from above