Overview
The document provides a detailed overview of CombiTac solutions, which facilitate simultaneous energy connections across various circuits such as compressed air, industrial vacuum, cooling fluids, and electrical (power and signal). These solutions are designed to ensure simple and accurate connections, enhancing time savings, reliability, and safety.
Key Features
  • Time Savings: Allows for the connection of energy circuits in a single movement.
  • Reliability: Offers proven reliability for up to 5 connection cycles per day, with design features that protect components from impacts and external stresses.
  • Safety: Features a single coupling position to prevent circuit reversal and flush-face connectors to avoid spills or leaks.
Technical Specifications
  • Pneumatic and Hydraulic Flow Rates: Provides detailed flow rate and pressure drop data for various module configurations.
  • Cooling Fluids: Equipped with non-spill, double shut-off couplings, with specific pressure and temperature ratings.
  • Compressed Air and Industrial Vacuum: Includes modules with single shut-off or full flow couplings, self-locking connections, and specific pressure and temperature limits.
  • Electrical Circuits: Features modules with various electrical contact sizes and ratings, including thermocouples, coaxial, fibre-optic, and data bus contacts.
Module Configurations
  • Manual connections with housing and base.
  • Rackable solutions for automatic connections.
Recommendations
  • Modules are intended for monitoring purposes only and should be connected and disconnected off-load.
  • Extra protection measures are required for applications with voltages exceeding extra low voltage standards.
Specifications
The document outlines the operating conditions for electrical circuits, including rated voltage and current, pollution degree 3, and overvoltage category III, in accordance with IEC 60664-1. It specifies the maximum cable cross-section and working temperature, with derating diagrams provided for different temperatures and cable sizes.
Procedures
Regular checks are recommended for modules with electrical contacts next to cooling couplings. The derating diagrams illustrate the continuous current that can flow through connector contacts without exceeding temperature limits, following IEC 60512-5-2 standards.
Standards and Norms
The document references several standards, including DIN VDE 0298-4, DIN EN 60204-1, IEC 60204-1, and UL 1977 for determining rated current and voltage. Overvoltage category III and pollution degree 3 are defined per CEI 60664-1.
Recommendations
For safety, metal housings must be earthed if voltage exceeds 30V AC or 60V DC, as per IEC 61140. Protective shields and covers are advised for housings to prevent electric shocks and external pollution.
Tools and Equipment
The document lists various crimping tools and dies for different conductor sizes, along with insertion and extraction tools for contacts. It also details housing options, including IP65-rated configurations and grounding solutions.
Diagrams and Data
Derating diagrams provide data on permissible current loads for different cable cross-sections and temperatures. Housing dimensions and configurations are detailed, with options for protective covers and grounding solutions.
See more

Catalog excerpts

CombiTac programme-1

CombiTac Preconfigured modules Simultaneous energy connection

 Open the catalog to page 1
CombiTac programme-2

CombiTac programme: a tailor‑made solution…

 Open the catalog to page 2
CombiTac programme-3

…for simple, accurate connections Centralised connection for optimised productivity and safety CombiTac solutions allow for the simultaneous connection of the following circuits: Time savings Optimised safety Connects the energy circuits for your process and on-site maintenance equipment in a single movement. A single coupling position to eliminate any risk of reversing the circuits Flush-face connectors for fluid circuits: this technology ensures no spills or leaks during connection and disconnection. Ideally suited to applications combining fluid and electrical circuits. Electrical contacts...

 Open the catalog to page 3
CombiTac programme-4

A customised solution for each application Because each application deserves a perfectly adapted response, a personalised CombiTac solution is created from a complete range of independent modules; modules are chosen and assembled to suit your individual requirements. A wide range of fully equipped modules Modules for cooling circuits Modules for pneumatic and industrial vacuum circuits Modules for electrical circuits Electrical contacts (7 diameters) Flush-face leak control technology Full flow or simple or double shut-off Specific contacts: thermocouples, coaxial, fibre-optic and data bus Multilam...

 Open the catalog to page 4
CombiTac programme-5

COOLING FLUIDS Modules fitted with non-spill, double shut-off couplings Technical characteristics Nominal diameter DN (mm) Maximum allowable pressure (bar) Minimum and maximum allowable temperatures TS (°C) Shut-off These characteristics are applicable to the equipped modules only. Please ensure the temperature and pressure ratings are not exceeded on any tubing connected to the modules. Pneumatic flow rate / pressure drop Test condition ■ irection of flow: socket D ■ upply pressure: 6 bar S Fluorocarbon: add /JV at the end of the part-numbers. Example: SCT 103 02 1100/JE Test condition ■ Direction...

 Open the catalog to page 5
CombiTac programme-6

COOLING FLUIDS Modules fitted with non-spill, double shut-off couplings Part numbers Modules fitted with SCT 03 for G 1/8 female connection Description SCT 03 Part numbers for modules fitted with LCT 06 Part numbers for modules fitted with SCT 03 Modules fitted with LCT 06 for G 1/4 female connection Number of LCT per module Description LCT 06 Working pressure bar

 Open the catalog to page 6
CombiTac programme-7

COMPRESSED AIR - INDUSTRIAL VACUUM Modules fitted with single shut-off or full flow couplings Technical characteristics Nominal diameter DN (mm) Maximum allowable pressure PS (bar) Minimum and maximum allowable temperatures TS (°C) Shut-off Seals Industrial vacuum up to (connected position) These characteristics are applicable to the equipped modules only. Please ensure the temperature and pressure ratings are not exceeded on any tubing connected to the modules. Pneumatic flow rate / pressure drop Test condition ■ irection of flow: socket D ■ upply pressure: 6 bar S Part numbers Modules fitted...

 Open the catalog to page 7
CombiTac programme-8

COMPRESSED AIR - INDUSTRIAL VACUUM Modules fitted with single shut-off or full flow couplings Part numbers Modules fitted with UCT 06 Number of UCT per module Part numbers for modules fitted with UCT 08 Connection tube outside Ø Part numbers for modules fitted with UCT 06 Self locking connection on to calibrated polyamide or polyurethane tubing. Modules fitted with UCT 08 Number of UCT per module Description UCT 08 Connection tube outside Ø Working pressure bar mm inches 15 Self locking connection on to calibrated polyamide or polyurethane tubing.

 Open the catalog to page 8
CombiTac programme-9

COMPRESSED AIR - INDUSTRIAL VACUUM Modules fitted with single shut-off or full flow couplings Technical characteristics Nominal diameter DN (mm) Maximum allowable pressure PS (bar) Minimum and maximum allowable temperatures (°C) 15 - 15 and + 80 full flow or single shut-off NBR Shut-off Seals Industrial vacuum up to (connected position) These characteristics are applicable to the equipped modules only. Please ensure the temperature and pressure ratings are not exceeded on any tubing connected to the modules. Pneumatic flow rate / pressure drop Test condition ■ irection of flow: socket D ■ upply...

 Open the catalog to page 9
CombiTac programme-10

COMPRESSED AIR - INDUSTRIAL VACUUM Modules fitted with single shut-off or full flow couplings Part numbers Modules fitted with RCT Full flow OS version Single shut-off ON version Modules fitted with RCT 03 full flow or single shut-off Description RCT 03 Number Connection tube outside Ø of RCT Working per module pressure bar mm ’’ plug plug socket socket Part numbers for modules fitted with Self locking connection on to calibrated polyamide or polyurethane tubing. Modules fitted with RCT 06 Single shut-off Description RCT 06 Number Connection tube outside Ø of RCT Working per module pressure bar...

 Open the catalog to page 10
CombiTac programme-11

ELECTRICAL CIRCUITS Modules fitted with electrical contacts Part numbers Modules fitted with Ø 0.6 mm electrical contacts Number of contacts Cable cross section mm2 Equipped module partnumbers with gold plated n Modules fitted with Ø 1 mm electrical contacts Number of contacts Cable cross section mm2 Equipped module partnumbers with gold plated n Modules fitted with Ø 1.5 mm electrical contacts Electricity Cable cross section mm2 Equipped module partnumbers with gold plated n Equipped module partnumbers with gold plated n Modules fitted with Ø 3 mm electrical contacts Electricity Cable cross...

 Open the catalog to page 11
CombiTac programme-12

ELECTRICAL CIRCUITS Modules fitted with electrical contacts Part numbers Modules fitted with Ø 6 mm electrical contacts Number of contacts Cable cross section mm2 ground socket Equipped module partnumbers with silver plated n Modules fitted with Ø 8 mm electrical contacts Number Rated Section of current câble contacts A mm2 Rated Type of voltage contact V socket Equipped module part-numbers with gold plated n earth socket Equipped module partnumbers with silver plated n Modules fitted with Ø 12 mm electrical contacts Number of contacts High current Cable cross section mm2 Equipped module partnumbers...

 Open the catalog to page 12
CombiTac programme-13

Modules fitted with contacts for Ø 2 mm thermocouples Cable cross section mm2 Equipped module part-numbers Type of contact type E Chromel + Constantan type K Chromel + Alumel type T Cuivre + Constantan type N Nicrosil + Nisil 2 thermocouple pressure contacts; 1 earth contact Modules fitted with RG 59 and RG 58 coaxial contacts according to CECC 22 120 Coaxial contact Number of Voltage contacts standing per module wave ratio Rated voltage earth shielding Cable cross section mm2 Impedance Type of ohm cable Equipped module part-numbers Modules fitted with 6 GHz coaxial contacts Coaxial contact Number...