1. Catalogs
  2. Stäubli Fluid Connectors
  3. CGD Thermal management

CGD Thermal management

CGD Thermal management

CGD Thermal management

Product catalog summary
Overview: The document provides detailed information on CGD quick-release couplings used for thermal management in various applications such as high-performance computing, data centers, medical, and broadcasting. The focus is on non-spill flush face technology that ensures fluid integrity and prevents contamination.
Key Features:
  • Non-Spill Technology: Ensures no pollution enters the circuit upon connection, maintaining cleanliness and safety.
  • Automatic Closure: The circuit closes automatically upon disconnection, preventing environmental contamination and making it suitable for electrical and high voltage environments.
  • Custom Sealing Solutions: Offers various elastomer options compatible with most fluids and a wide temperature range.
  • Performance and Reliability: High flow volume, resistance to vibration and corrosion, and designed for numerous connection sequences.
Technical Specifications:
  • Materials: Constructed from aluminum alloy with surface treatment or nickel-plated brass.
  • Seal Types and Temperature Ranges: Fluoro-silicone (-40° to +175°C), Ethylene-propylene (-20° to +150°C), Fluorocarbone (-10° to +200°C).
  • Pressure and Temperature Limits: Maximum allowable pressure of 16 bar for nickel-plated brass and anodized aluminum, with temperature ranges from -40°C to +200°C.
  • Connection Force and Fluid Loss: Varies by model, with connection forces ranging from 40 to 150 N and minimal fluid loss on disconnection.
Installation and Part Numbers:
  • Detailed part numbers for sockets, plugs, and module plugs are provided, with instructions to add seal codes for specific requirements.
  • Installation guidelines include maximum misalignment and mechanical stop specifications, with machining plans available on request.
Additional Information: The document notes that Stäubli reserves the right to modify product specifications without prior notice and provides contact information for further inquiries.
See more

Catalog excerpts

CGD Thermal management-1

CGD quick-release couplings Thermal management

 Open the catalog to page 1
CGD Thermal management-2

Flush face technology…

 Open the catalog to page 2
CGD Thermal management-3

Non spill flush face technology guarantees the integrity of the fluid No pollution can enter the circuit on connection. Non-drip to ensure cleanliness and safety of installations and operators. Thanks to the CGD connector, the circuit is automatically closed upon disconnection: ■ No contamination of the environment due to fluid loss ■ Suitable for electrical and high voltage environments Performance and reliability ■ High flow volume ■ Resistance to vibration and corrosion ■ Designed to withstand numerous connection sequences. Applications ■ High performance computer ■ Data center ■ Medical ■...

 Open the catalog to page 3
CGD Thermal management-4

Displacement technology A solution suitable for guiding systems with a maximum misalignment of 1 mm. Maximum distance between 2 axes: 1 mm Distance maxi. entre les 2 axes : 0.5 mm The opportunity to spend less and contribute to a sustainable development programme. With Stäubli, you can rely on the performance of your equipment, reliability of long-term investments and no workplace pollution. CGO à double oscillation (raccord oscillant + about oscillant) ou CGO à simple oscillation (raccord non oscillant + about oscillant

 Open the catalog to page 4
CGD Thermal management-5

Technical characteristics Construction: aluminium alloy with surface treatment or nickel-plated brass Type of seal Seal code -40° to +175° (down to -50° depending on the fluid) To select the type of seal on your CGD sockets and plugs, add the «seal code» to the end of the part number. E.g.: CGD 05.2416/JV for a CGD with fluorocarbon seals. CGD 03 Connection force without pressure (N) Repulsion cross section (cm²) Fluid loss on disconnection (cm3) Nominal diameter DN (mm) Nickel-plated brass Maximum allowable pressure PS (bar) Anodized aluminium Minimum and maximum allowable temperatures TS (°C)...

 Open the catalog to page 5
CGD Thermal management-6

Part numbers Socket F Part numbers Aluminium Part numbers Aluminium Part numbers Aluminium Add the seal code to the end of the part number. Seal code

 Open the catalog to page 6
CGD Thermal management-7

misalignment d mechanical stop: b Installation drawing reference misalignment d mechanical stop: b Installation drawing reference Plug installation into recessed pocket Machining plans available on request.

 Open the catalog to page 7
CGD Thermal management-8

Stäubli units Global presence of the Stäubli Group www.staubli.com Staubli is a trademark of Stäubli International AG, registered in Switzerland and other countries. © Stäubli 25/01/2023. We reserve the rights to modify product specifications without prior notice. [email protected] | Photos crédits: Stä

 Open the catalog to page 8

All Stäubli Fluid Connectors catalogs and technical brochures

  1. CER

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.