1. Catalogs
  2. SRA
  3. R490 M MicroGC

R490 M MicroGC
1 /2Pages

R490 M MicroGC

R490 M MicroGC
1 /2Pages

Catalog excerpts

R490 M MicroGC-1

R490 M MicroGC Specifications ➢ Rapid analysis of the quality of Biomethane, of its certified Metrology SHV and of THT ➢ 5U 19" Rack ➢ Turnkey analysis ➢ Modbus link to supervisor or PLC ➢ Serial Modbus link dedicated to Metrology The measurement of the quality of Biomethane and its heat value are essential parameters before injection into the natural gas network. The R490 M analyzer has been developed to meet this requirement. Immediate start-up. The instrument is delivered ready for use with acceptance report. The entire analytical method is provided with the device. Compact system. The system is mounted in a 5U 19" Rack compatible with standard analysis bays. Connection. The R490 M is designed to be connected by serial Modbus link to allow the transmission of results. Quick analysis. The R490 M can perform a measurement every 3 minutes. __________ Configuration : • Two specific channels for the analysis of the quality of Biomethane, H2S, COS and the certified SHV measurement • A third channel with a dedicated sample input for the analysis of THT or other compounds • Computer and embedded software including: - Automation - Piloting - Control - Integration and calculation - Modbus tables SRA INSTRUMENTS 210 rue des Sources 69280 Marcy l'Etoile FRANCE System settings : • With the Soprane software installed on the embedded PC • Possibility to connect directly screen, keyboard, mouse on the analyzer for maintenance operations • Possibility of remote control via Ethernet connection SAS au capital de 150.000 € RCS Lyon B 342 068 731 APE 4669B SIRET: 342 068 731 00054 Co

 Open the catalog to page 1
R490 M MicroGC-2

Injector : • Miniature without moving part • Variable injection volume from 1 µL to 10 µL programmable by software • Heated Sample : • Swagelok stainless steel inlet connection • Integrated high capacity 5µm dust filter • Maximum inlet pressure 1 bar rel. • Minimum inlet pressure 0.1 bar rel. Oven : • Isotherm can be set from 40 °C to 180 °C Environment : • Relative humidity : 0 to 95 % • Temperature : -10 °C to 40 °C Detector : • Micro catharometer (TCD) • Two channels (sample and reference) • Internal volume: 200 nL per channel • Filaments: 4 Quantification limit : • a few ppmV Measuring range...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.