The CM is the smallest external-mount end block, suitable for smaller or R&D systems. It is available in two designs for 125 mm and 80 mm ID targets. External end blocks offer wider substrate coverage compared to internal models. Customizable drive shaft lengths and 360° positioning of drive motors are available. Magnet bar adjustments can be made externally, and all utilities remain attached during target changes. The water seal cartridge is easily accessible for quick replacement. Suitable for new systems or upgrades from planar systems, with coater integration support available from SCI.
Note: The formulas assume a stainless steel backing tube; adjustments are needed for long drive shafts or if a RAM-Bar™ is used.
External-Mount End Block The CM is our smallest external-mount end block and is an excellent choice for smaller systems or R&D systems. There are two designs: one for a 125 mm ID and another for an 80 mm ID target. External end blocks have a wider substrate coverage than internal models. To match any system, drive shaft length is customizable, and drive motors can have 360° positioning around the main housing. Magnet bar adjustments—to any angle—are made externally. All utilities are external and remain attached during target changes. The water seal cartridge is easily accessed for quick replacement. Use in new systems or upgrade from planar systems. SCI can provide coater integration support. TECHNICAL SPECIFICATIONS Maximum O 20 kW DC Target Length Maintenance Q 1 hr./yr. average rff SPUTTERING. XpJfJ COMPONENTS
Open the catalog to page 1Cantilever capability Metric: XY/2 + 16X2 < 39 Imperial: XY/2 + 0.9X2 < 3,400 X = Backing tube length (meters or inches) Y = Weight of target (kg or lb only) Notes: The formula assumes a stainless steel backing tube; other materials may not qualify. The formula must be adjusted for long drive shafts or if a RAM-Bar™ will be used.
Open the catalog to page 2DRIVE SHAFT (VARIES) ABSOLUTE MINIMUM DRIVESHAFT LENGTH = WALL THICKNESS +20mr Cantilever capability Metric: XY/2 + 10X2 < 19.5 Imperial: XY/2 + 0.33X2 < 1,700 X = Backing tube length (meters or inches) Y = Weight of target (kg or lb only) Notes: The formula assumes a stainless steel backing tube; other materials may not qualify. The formula must be adjusted for long drive shafts. 375 Alexander Drive, Owatonna, MN USA • 507-455-9140 [email protected] * www.sputteringcomponents.com SPUTTERING. COMPONENTS
Open the catalog to page 32 Pages
2 Pages
2 Pages
2 Pages