Catalog excerpts
Safety tester ingle devices » Leakage current test devices » AI 5001A The safety test of electrical devices must, after having been tested without current and depending on the relevant test standard, be completed by a line leakage measurement with increased rated voltage. Only by means of the line leakage test is it possible to activate the internal controls in case of electro-mechanical devices. Series AI 5000 offers 3 different techniques. While tester AI 5000A draws its test voltage directly from the power supply, tester AI 5000P applies a safety isolating transformer. A further and important feature of the testers is the cutting-in. With testers AI 5001A, AI 5000P and AI 5010D an operating mode change-over is possible without turning off the supply voltage of the DUT. Spcial features conforms to CE, in accordance with EN 50 191 optical and audible alarm analogue measuring instrument for voltage, class 1.5 analogue measuring instrument for current, class 1.5 potential free PLC remote control interface potential free analogue output for voltage (0 up to 10 VDC) potential free analogue output for current (0 up to 10 VDC) built-in adjustable stress increase from 100% up to 110% feed-in for external testing voltage Technical Data output (main voltage 230 VAC) 230 V - 256 V / 16 A » potential power supply » phases 1 output (main voltage 115 VAC) 115V - 128V/16 A output (external voltage supply) 60 V - 300 V / 16 A » potential power supply » phases 1 operating modes A (L/PE) / B (N/PE) recognition phase yes measuring rang 1 mA / 10 mA interruption when changing mode of operation no plug-in 19" / 4 HU power supply 230 V / 50 Hz or 115 V / 60 Hz Headquarter: Bltter頠cker 18 I D-74523 Schwbisch Hall Phone +49 7907 878-0 I Fax +49 7907 878-99 info@spselectronic.com I www.spselectronic.com Settlement North: BoschstraRe 15 I D-49767 Twist Phone +495936 91815-0 Fax +49 5936 91815-99
Open the catalog to page 1All SPS electronic GmbH catalogs and technical brochures
-
Multifunction KT 1886B/J
1 Pages
-
Hipot tester HA 1885J
1 Pages
-
Product Catalogue 2018
21 Pages
-
Relay RL 42h - RL 38h
1 Pages
-
HA 3600D
1 Pages
-
Surge Tester ST 3800L
1 Pages
-
Surge Tester ST 1800B
1 Pages
-
Line leakage AI 5601D
1 Pages
-
Insulation IS 580F
1 Pages
-
Ground bond P 1800D
1 Pages
-
High voltage HA 1885G
1 Pages
-
High voltage HA 1800M
1 Pages
-
Multifunction KT 1885L
1 Pages
-
Multifunction KT 1885K
1 Pages
Archived catalogs
-
High voltage HA 3881B
1 Pages
-
High voltage HA 3881J
1 Pages
-
High voltage HA 3881G
1 Pages
-
Multifunction KT 3881H
1 Pages
-
Multifunction KT 3881F
1 Pages
-
Multifunction KT 3881E
1 Pages
-
Multifunction KT 1885J
1 Pages
-
Testing system for motors
1 Pages
-
Testing system for stators
1 Pages
-
EOL-Tester
1 Pages
-
Testing System for PDU
1 Pages
-
Mobile testing system
1 Pages
-
LG 3881E
1 Pages
-
KT 3301B
1 Pages
-
LG 3301E
1 Pages
-
LG 1800B
1 Pages
-
S 3301B
1 Pages
-
HA 5012L
1 Pages
-
HA 3881B
1 Pages
-
IS 580F
1 Pages
-
IL 3881F
1 Pages
-
IL 3801F
1 Pages
-
Test adapters
1 Pages
-
AI 5601D
1 Pages
-
Test adapter
1 Pages
-
Data sheet KT 3301K
1 Pages
-
Data sheet KT 3881B
1 Pages
-
Data sheet LG 3301K
1 Pages
-
Data sheet LG 3301D
1 Pages
-
Data sheet LG 3801E
1 Pages
-
Data sheet HA 3600A
1 Pages
-
Data sheet P 3301D
1 Pages