video corpo cad

WKE - Overview
2Pages

{{requestButtons}}

Catalog excerpts

WKE - Overview - 1

Name Order number What is functional integrity? Functional integrity is given if, during a fire, there is no short circuit and no interruption of the current flow in the electrical pipe system. Components which comply with DIN 4102 Part 12 are high-voltage power lines, installation cables and lines, busbar trunking systems, cable ducts, coatings, claddings, and all necessary connecting elements, carrying devices and fittings. Lines and components are always tested as an entire system by the approved inspection bodies from the German Institute of Structural Engineering (Deutsches Institut fur Bautechnik - DiBt). Cable gland clamping areas Modules Distribution board Material enclosure Enclosure colour light grey light grey light grey light grey light grey light grey light grey light grey light grey light grey Functional integrity in accordance in accordance in accordance in accordance in accordance in accordance in accordance in accordance in accordance in accordance with MLAR with MLAR with MLAR with MLAR with MLAR with MLAR with MLAR with MLAR with MLAR with MLAR Fire load insulation in accordance in accordance in accordance in accordance in accordance in accordance in accordance in accordance in accordance in accordance with MLAR VDE test mark Protection class WKE Duo Cable junction and connection boxes E 30 / E 60 / E 90 in accordance with DIN 4102, Part 12 WKE 2 - 5 Junction boxes E 30 / E 60 / E 90 in accordance with DIN 4102, Part 12 WKE 54 Junction box E 30 / E 60 / E 90, DIN 4102, Part 12 Number of clamping conductors per pole or clamping unit M PA-tested For installation of different cable cross-sections in a terminal Without a limit up to the nominal cable cross-section Quick mounting due to outer installation 5 enclosure sizes equipped with terminals from 6 to 16 mm2 Fully pre-assembled MPA and VDE-tested Plastic enclosure, insulation protected Quick mounting due to outer installation 6 Standard types from 0.5 to 16 mm2 Flexible cable entries Fully pre-assembled Upgradable to IP65 Ideal for building technology MPA and VDE-tested Plastic enclosure, insulation protected Outside installation Double terminal 162 Flexible equipment Secured outflow Robust enclosure Ideal for tunnels and industrial areas Terminal 62 Tightening torque 0.8 Nm Terminal 102 Tightening torque 1.2 Nm Terminal 162 Tightening torque 2.0 Nm Protection type IP (EN 60670) Nominal voltage (DIN IEC 60998-2-5) Impact strength IK (DIN EN 50102) Ambient temperature Installation 20 20 = Single terminal, 2 clamping units = double terminal 4 clamping units Intrinsic fire resistance Special features Usable cable manufacturer and cable Equipment with type-tested operating materials Double membrane socket, cover and label strips DIN 4102; VDE Equipment with type-tested operating materials Double membrane socket, cover and label strips DIN 4102; VDE Equipment with type-tested operating materials Double membrane socket, cover and label strips DIN 4102; VDE Equipment with type-tested operating materials Double membrane socket, cover and label strips DIN 4102; VDE Equipment with type-tested operating materials Double membrane socket, cover and label strips DIN 4102; VDE Equipment with type-tested operating materials Double membrane socket, cover and label strips DIN 4102; VDE Equipment with type-tested operating materials Double membrane socket, cover and label strips DIN 4102; VDE Equipment with type-tested operating materials Double membrane socket, cover and label strips DIN 4102; VDE Equipment with type-tested operating materials Double membrane socket, cover and label strips DIN 4102; VDE Equipment with type-tested operating materials Double membrane socket, cover and label strips DIN 4102; VDE Interior area/ Building technology Interior area/ increased requirement Underground parking, Service passageways Protected outside area/parking garages Railway tunnels Road tunnels Special structures/ Special types Sophisticated fire protection = suitable WKE 200 - WKE 400 Junction boxes E 30 in accordance with DIN 4102, Part 12 MPA and VDE-tested Plastic enclosure, insulation-protected Clamping area up to 352 Flexible equipment Secured outflow with functional integrity Particularly robust Ideal for saving time and materials Planning in building technology IfE18oI WKE Rapid Box Switchgear assembly E 30 / E 60 / E 90 in accordance with EN 1363 (MPA) Contact from uncut conductors up to 50 mm2, also retroactively Maintenance free and secured mantle terminal with revolving, elastic pressure piece and reverse lock Tap via spring-cage terminal Simplified line mounting during installation Uninterrupted power supply via uncut conductors Small distribution board MPA and VDE-tested VDE-tested in accordance with EN 61 439-1 Individually equipped with type-tested operating materials Fire resistance to flames on exterior EI 90 in accordance with EN 13501 Protection of the electrical fixtures Fire resistance to flames on interior EI 90 in accordance with EN 13501 Protection of the environment from fire in the electrical system Gunther Spelsberg GmbH + Co. KG Headquarter Im Gewerbepark 1, D-58579 Schalksmuhle, Germany Postfach 15 20, D-58571 Schalksmuhle, Germany Tel: +49 (0) 23 55 8 92-0 E-mail: info@spelsberg.de Internet: www.spelsberg.de WKE junction boxes and distribution boards |P

Open the catalog to page 1
WKE - Overview - 2

Name Order number EAN Dimensions in mm (L x W x H) Clamping area Pole Material terminal Material enclosure Enclosure colour Approved cable entries Functional integrity Insulation integrity Functional life Fire load insulation VDE test mark Protection class Protection type IP (EN 60670) Nominal voltage (DIN IEC 60998-2-5) Impact strength IK (DIN EN 50102) Pressure suction test Ambient temperature UL fire test Installation Mounting on cable tray Special features Accessories 5 feed-through 3 branch 5 Thermoset Thermoset Thermoset Thermoset Attachment socket Sealing plug Installation kit...

Open the catalog to page 2

All Spelsberg catalogs and technical brochures

  1. Mini 25-L

    4 Pages

  2. Abox SLK 4²

    3 Pages

  3. ZKi 1-f

    2 Pages

  4. ZKi 1

    2 Pages

  5. AL MPS-2616

    1 Pages

  6. AL 55-3

    2 Pages

  7. AKi 14-1L

    1 Pages

  8. AKi 1-2L

    1 Pages

  9. STV 502-S

    1 Pages

  10. STG 012-L

    1 Pages

  11. DMS M25

    1 Pages

  12. KVR M63-MGM

    2 Pages

  13. VST M20/or

    1 Pages

  14. WKE 54

    2 Pages

  15. WKE AK 14 R

    2 Pages

  16. AKi-TE 108

    1 Pages

  17. AKi-SK 452

    2 Pages

  18. AKi-S 202

    2 Pages

  19. BST M20

    1 Pages

  20. AL MPS-2320

    1 Pages

  21. AK MPI 3

    1 Pages

  22. AKL 1-t

    2 Pages

  23. AKi 1-g

    2 Pages

  24. TG PC 88-6-o

    2 Pages

  25. TK MPI-75

    1 Pages

  26. The Company

    16 Pages

  27. Catalogue 2017

    362 Pages

  28. KVR M12

    2 Pages

  29. RST M20

    1 Pages

  30. RST M20-16

    1 Pages

  31. ADR M63

    1 Pages

  32. ADR M25

    1 Pages

  33. ARI Pg 29

    1 Pages

  34. ARI Pg 21

    1 Pages

  35. ARI Pg 9

    1 Pages

  36. AP 7 - L

    2 Pages

  37. AP 7 - 2,5²

    2 Pages

  38. Q 12 SB-L

    2 Pages

  39. Q 12-L

    2 Pages

  40. Q 12-2,5²

    2 Pages

  41. Q 4-L

    2 Pages

  42. WKE DUO

    4 Pages