video corpo

PA14-500

PA14-500

PA14-500

Product catalog summary
Applications
  • Power amplifier for modal testing shaker
  • Power amplifier for environmental testing systems
Range of Use
  • Research and development departments in industry
  • Environment testing laboratories
  • Universities and research institutes
Features
  • Frequency range: DC to 150 kHz
  • High reliability operation
  • Switch between Voltage and Current Mode
  • Phase Shift (0° or 180°)
  • Variable Gain Control
  • Current Limit Control
  • Temperature Protection
  • Control Mute Input
  • Multifunction LCD Display
Description

The Power Amplifier Type PA14-500 is designed to drive exciters requiring a 500 VA power amplifier. It operates within a frequency range of 40 Hz to 65 kHz at full power and DC to 150 kHz at small power, with minimal harmonic distortion. It can function as a voltage generator with low output impedance or a current generator with high output impedance. The RMS output-current limit is adjustable, with voltage mode recommended for standard applications.

Technical Data
  • Power Output: Max 500 VA into a 4 Ohm resistive load
  • Frequency Range: Full power 40 Hz to 65 kHz; Small signal DC to 150 kHz
  • Voltage Output: Max 45 V RMS
  • Current Output: Varies from 5 A to 11 A RMS depending on frequency
  • Input Voltage: < 5 V
  • Input Impedance: > 10 kOhm
  • Power Supply: Preset to 100 V, 120 V, or 230 V RMS ± 5 %, 50/60 Hz
  • Monitor Output: Voltage and current monitor with specific ranges
  • Dimensions: Width 482 mm, Height 88 mm, Depth 450 mm
  • Weight: 21 kg
Performance
  • Voltage Mode Bandwidth: Full power 40 Hz to 65 kHz; Small signal DC to 150 kHz
  • Gain: Nominal 18 V/V with specific dB variations
  • Total Harmonic Distortion: Varies by frequency range
  • Signal-to-Noise Ratio: > 90 dB
  • Current Mode Bandwidth: Full power 40 Hz to 65 kHz; Small signal 5 Hz to 60 kHz
  • Gain: Nominal 12 A/V with specific dB variations
  • Total Harmonic Distortion: Varies by frequency range
See more

Catalog excerpts

PA14-500-1

• Power amplifier for modal testing shaker • Power amplifier for environmental testing systems Range of Use • Research and development departments in industry • Environment testing laboratories • Universities and research institutes Frequency range DC...150 kHz High reliability operation Switch between Voltage and Current Mode Phase Shift (0° or 180°) Variable Gain Control Current Limit Control Temperature Protection Control Mute Input Multifunction LCD Display Description The Power Amplifier Type PA14-500 has been developed to drive any type of exciter requiring a 500 VA power amplifier. It has an useable frequency range from 40 Hz to 65 kHz at full power or from DC to 150 kHz small power; the harmonic distortion is hereby very small. The power amplifier can tolerate temperature and supply line variations while maintaining excellent stability. Thereby, the product can be used as a voltage generator with low output impedance and a flat voltage frequency response, or as a current generator with high output impedance and a flat current frequency response. The maximum RMS output-current limit is adjustable. For standard application, we recommend using the product in voltage mode. Page 1 of 2 SPEKT

 Open the catalog to page 1
PA14-500-2

PA14-500 Power Amplifier Technical Data General Power Output, max. Frequency Range 500 VA into a 4 Ohm resistive load Full power 40 Hz;65 kHz Small signal (-20 dB) DC...150 kHz Current Output Input Voltage Input Impedance Input Capacity Power Supply (preset) <5V > 10 kOhm > 47 pF preset to either 100 V or 120 V or 230 V RMS ± 5 %, 50 Hz / 60 Hz, single phase, AC mains supply, 1 170 VA power consumption at full load Voltage monitor 0.1 V / V ± 3 %, 0.1 Hz...15 kHz Current monitor 0.1 V / A ± 3 %, 0.1 Hz...15 kHz Width 482 mm (19 in), with flanges standard 19" rack Height 88 mm (3.5 in), corresponds...

 Open the catalog to page 2

All SPEKTRA Schwingungstechnik und Akustik GmbH Dresden catalogs and technical brochures

  1. DRE-01

    4  Pages

  2. SQ-4.2

    2  Pages

  3. SQ-4.1

    2  Pages

  4. S-TEST/16 Lab

    2  Pages

  5. S-TEST/16 Fab

    2  Pages

  6. S-TEST/2

    2  Pages

  7. FDG-15

    2  Pages

Archived catalogs

  1. SE-10

    3  Pages

  2. SQ-101

    2  Pages

  3. PA14-180

    2  Pages

  4. VCS 401

    2  Pages

  5. CS18 SPL-VLF

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.