video corpo

CoolCheck 2

CoolCheck 2

CoolCheck 2

Product catalog summary
Overview: CoolCheck 2 is an automated system designed for non-experts to measure and profile coolant condition and diesel exhaust fluid (DEF) integrity. It performs nine tests in under 45 seconds, providing results graded as NORMAL, ABNORMAL, or SEVERE, along with corrective advice to prevent potential failures.
Key Features:
  • Replaces hazardous chemicals and manual testing methods.
  • Prevents common cooling system issues such as mixed fluid types, depletion of additives, and system contamination.
  • Ensures correct DEF levels to maintain engine efficiency and emission reduction.
Principle of Operation: Utilizes a patented near IR and UV/Visible dual spectrometer to measure absorption spectra, providing immediate results with a traffic light style report. The test duration is less than a minute.
Tests Conducted:
  • Coolant Tests: Type, clarity, color, contamination, glycol content, boil point, freeze point, nitrites.
  • DEF Tests: % Urea, % DEF.
Product Information:
  • Part Number: 42000-00 CoolCheck 2 Analyzer.
  • Requires Standard Accessory Kit (29701-00).
  • Optional LubeTrak® data management software for organizing test data and maintenance recommendations.
Device Specifications:
  • Spectral Range: 200-1100 nm.
  • Detectors: Dual-Path multi-wave spectrometer with dual Xenon light source.
  • Calibration: Polynomial 2nd/3rd order fit using 3 standard fluids.
Operational Specifications:
  • Sample Volume: 0.5 oz. (15 ml).
  • Sample Time: 45 seconds.
  • Operating Temperature: 0-40°C.
  • Humidity: 5-95% (non-condensing).
  • Altitude: Up to 11,500 feet (3000 meters).
User Interface:
  • Display: Touch screen.
  • Data Entry: Touchscreen/USB port.
  • Data Storage: 16 GB internal.
  • Data Transfer: LAN/wireless (FTP).
Power Requirements:
  • Power: 115/230V, 50/60 Hz, single-phase.
  • Consumption: 20 Watts.
Mechanical Specifications:
  • Dimensions: 10.5” x 9” x 4.5” (28cm x 23cm x 11.5 cm).
  • Weight: 4.6 lbs. (2.1 kg).
Accessories & Consumables:
  • Includes sample vials, printer paper, sample extractor tubing, control sample kit, and more.
  • Optional LubeTrak® Software for data management and alerts.
Contact Information: AMETEK Spectro Scientific, Chelmsford, MA. Phone: 978-431-1120. Website: www.spectrosci.com.
See more

Catalog excerpts

CoolCheck 2-1

CoolCheck® 2 AUTOMATED COOLANT AND DIESEL EXHAUST FLUIDS ANALYSIS SYSTEM Accurate, on-location testing in seconds Cooling systems play a vital role in preserving overall engine heat balance and in protecting engine components. Testing your coolant and maintaining your system at optimum levels will help prevent: ■ Corrosion, pitting, rust build-up ■ Damaged seal/coolant leaking into oil ■ Overheating, boil-over, engine seize-up ■ Engine damage from freezing As an added benefit, CoolCheck 2 tests for correct DEF levels. An incorrect DEF mixture can also be harmful: ■ Reduces engine efficiency ■Negates emission reduction efforts COOLANT TESTS - Coolant type - Clarity - Color - Contamination - Glycol content (%) - Boil point - Freeze point - Nitrites (ppm) DEFTESTS - % Urea - % DEF CoolCheck 2 provides measurement and profiling of coolant condition and diesel exhaust fluid (DEF) integrity. Designed for use by the non-expert Executes 9 different tests in less than 45 seconds Measured results are also graded as: > NORMAL > ABNORMAL > SEVERE Provides corrective advice to avoid potential failures before they happen Replaces hazardous chemicals, time-consuming titration methods and inaccurate test strips used in manual testing CoolCheck 2 helps prevent the most common problems with cooling systems Mixed fluid types Depletion of key performance additives System contamination Principle of Operation The core of CoolCheck 2 coolant and DEF analyzer is the patented near IR (NIR) and UV/Visible dual spectrometer that measures the absorption spectrum at these two wavelengths simultaneously using a unique sample vial. Physical parameters are extrapolated from the obtained spectrum with special calibrations (done in the factory). Alarm limits stored in the device provide a traffic light style report for immediate decision making. The entire test takes less than a minute.

 Open the catalog to page 1
CoolCheck 2-2

Optional LubeTrak® Software allows managers to effectively maintain the health and efficient operation of equipment. Users can organize test data and maintenance recommendations from the CoolCheck 2 in a database with easy to use analysis and tracking capability. Stores analysis history Tracks equipment results Displays 'red flag' problems Sends alerts to computer or smart phone Exportable data AMETEK Spectro Scientific | One Executive Drive, Suite 101, Chelmsford, MA 01824-2563 978-431-1 120 | www.spectrosci.com | [email protected] | An ISO 9001:2015 company Copyright © 2018 Spectro Scientific....

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.