Product Description: The 4057 is a programmable pulse multiplier, divider, or K-factor scaler with an optional analog output converter. It features a backlit LCD screen and push-button dial for easy mode selection. It supports inputs from various sources like magnetic VRS, RF, digital amplified pickups, and proximity sensors. The device can multiply or divide input frequency by a user-selected integer, and the optional analog output provides adjustable voltage or current signals.
Specifications:
  • Supply Voltage: 12-30 VDC
  • Supply Current: 75 - 120 mA
  • Input Types: VRS (Mag), RF, Digital
  • Frequency Input Range: VRS (Mag) 3 Hz to ~35 KHz, RF 0.5 Hz to ~7 KHz, Digital 0.3 Hz to ~80 KHz
  • Max Frequency Output: 80 KHz
  • Multiplier Options: Range 2 to 50,000 (integers only)
  • Divider Options: Range 1 to 999,999,999 (integers only)
  • Analog Output Options: FTV Outputs (0-5V or 0-10V), FTC Outputs (4-20mA, 0-20mA, or 0-24mA)
  • Operating Temperature Range: -20° to 75°C with Vs=12V, -20° to 55°C with Vs=30V
Wiring Instructions:
  • VRS (Mag) or RF Sensor Wiring: Power (1 - V+, 12-30 VDC, 2 - Common), Inputs (3, 4 - Mag or RF Pickup Coil), Outputs (6 - Digital Frequency Output, 7 - Common)
  • Active Sensor or Digital Input Wiring: Power (1 - V+, 12-30 VDC, 2 - Common), Inputs (5 - Digital Signal Input), Outputs (6 - Digital Frequency Output, 7 - Common)
Order Information:
  • Digital Output Type: Options include 0-5V, 0-10V, 0-12V, 0-Vs, and PNP
  • Output Options: Digital Frequency Output or with added Analog FTV/FTC Outputs
  • Input Types: Digital Signal Input, VRS (Mag) with various sensitivities, RF4, RF10
  • Mounting Type: Back Panel Mount or Control Panel Mount
See more

Catalog excerpts

4057  PULSE MULTIPLIER/DIVIDIER/K-FACTOR SCALER  W/ OPTIONAL ANALOG OUTPUT-1

4057 PULSE MULTIPLIER/DIVIDIER/K-FACTOR SCALER W/ OPTIONAL ANALOG OUTPUT PA-50 PRODUCT DESCRIPTION The 4057 is a user programmable pulse multiplier, divider, or K-factor scaler. An optional analog output converter can be included, which requires no external test equipment for setup. Output modes are quickly selected via a backlit LCD screen and push-button dial. Models are available for inputs from magnetic VRS, RF, digital amplified pickups, proximity sensors/switches, and other square wave sources. Removable terminal blocks can be factory configured for back panel or control panel mounting. The input frequency can be either multiplied or divided by a user selectable integer. The optional analog output can provide either a voltage or current signal with both minimum and maximum set points adjustable. To multiply by a decimal value (e.g. 10.123) please see the 4057D Bulletin. Push-Button Dial Input Type/Sensitivity: VRS (Mag): 5, 12, 30, 50 or 100mVpp RF: 4 or 10 Ohms Digital: CMOS, TTL, 0-30V, or PNP Frequency Input Range: Digital Output Options: Multiplier Options*: Range: 2 to 50,000 (Integers only) (only up to 80 kHz max frequency) Divider Options*: Range: 1 to 999,999,999 (Integers only) Pulse Width: 1 µs to 10s (frequency dependent) Removable Terminal Block (Back Panel Mount Shown) *NOTE: Not suitable for timing or synchronization applications with current Revision D Firmware. This is due to repeatability limitations with pulse width fluctuations from regular VRS/Mag, Hall Effect, and Digital sensors. Revision E Firmware is in development. Please contact factory. Analog Output Options: FTV Outputs: 0-5V or 0-10V ±0.01 % FSR typ. ±2 ppm/°C output drift FTC Outputs: 4-20mA, 0-20mA, or 0-24mA ±0.01mA Back Panel Mount Control Panel Mount .7in 17mm (Both Minimum and Maximum frequencies are adjustable) Operating Temp. Range: -20° to 75°C (-4° to 167°F) with Vs=12V -20° to 55°C (-4° to 131°F) with Vs=30V Terminal Connections:

 Open the catalog to page 1
4057  PULSE MULTIPLIER/DIVIDIER/K-FACTOR SCALER  W/ OPTIONAL ANALOG OUTPUT-2

ORDER INFORMATION STYLE: 4057 Digital Output Type: Output Options: Input Type(s): Programmable Signal Converter 1 - 0 - 5V, NPN [TTL] 2 - 0 - 10V, NPN 3 - 0 - 12V, NPN 4 - 0 - Vs, NPN 5 - 0 - Vs, NPN (OC), Open Collector 6 - PNP 1 - Digital Frequency Output (Standard Model: Multiplied/Divided/K-Factor Scaled Output Only) 2 - Same as above with added Analog FTV/FTC Outputs 1 - Digital Signal Input only 2 - VRS (Mag) 100mVpp Sensitivity 3 - VRS (Mag) 50mVpp Sensitivity 4 - VRS (Mag) 30mVpp Sensitivity 5 - VRS (Mag) 12mVpp Sensitivity 6 - VRS (Mag) 5mVpp Sensitivity 7 - RF4 8 - RF10 Digital Signal...

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.