Flux monitoring system for Generators
2Pages

{{requestButtons}}

Catalog excerpts

Flux monitoring system for Generators - 1

Flux Monitoring System for Generators with Salient Poles Continuous High Speed Acquisition of Rotor Flux Profile Ethernet and Modbus RTU Interfaces Standalone Operation Local True Color Touch LCD General Description Rotor Short Turn Detection of Generators with salient poles The Flux monitoring system for generators with salient poles is based on the UDL-8000 data acquisition and monitoring system family for online condition monitoring of high voltage insulation systems and machines. UDL-8000 is a multi - modular system with a central CPU controller, various different signal conditioning modules and sensor interfaces (up to eight modules per controller) and application specific software packages as e.g. the package FLMS used for the acquisition, evaluation and monitoring of the rotor flux of generators with a salient pole rotor. The rotor flux is measured by the ASC Series flux sensors installed within the airgap of the generator. The flux sensors are connected via the module M8009 to the UDL-8000 monitoring system. The module offers the interface for a reference sensor or AC reference source, one flux sensor and five 4-20mA analogue inputs for the acquisition of the machine operation condition, The UDL-8000 Controller offers standard interfaces as Ethernet, digital in - and outputs, relay contacts and Modbus RTU. The Ethernet Interface is used for the communication with the analysis software running on a windows based computer for the real-time data visualisation and analysis. Additionally the UDL-8000 system can be connected to the TMS-2000 Database Server to record continuous the acquired signals (Monitoring). Ordering Information Order Code: 16.8000.E2.B28-0C8-2.C1.09.FLMS Flux Monitoring System for Salient Pole Rotors 35mm DIN Rail Mounting, 24VDC

Open the catalog to page 1
Flux monitoring system for Generators - 2

Flux Monitoring System for Generators with Salient Poles Technical Data Flux Sensor Input Sampling Rate: A/D Resolution: Input Impedance: 100kOhm, Differential No. of Sensor Interfaces: 2 Reference Channel 1 Input Range: Frequency Range: Galvanical Insulated: Input Impedance: Reference Channel 2 Input Range: Frequency Range: Input: Input Impedance: Operation Parameters No of Channels: Input Range: Input: Measurement Shunt: 2500VAC 10M Ohm Differential 100 kOhm Single Ended 250 Ohm UDL-8000 Controller _______________________________________________________ Relais Contacts NO/NC Contact...

Open the catalog to page 2

All Sparks Instruments SA catalogs and technical brochures