1. Catalogs
  2. Sparkle Power
  3. FSP018M Series

FSP018M Series

FSP018M Series

FSP018M Series

Product catalog summary
Features:
  • Wide input voltage range from 85 to 264 VAC.
  • Operates at high altitudes up to 5000 meters.
  • Complies with EN55011 and FCC Class B standards.
  • High efficiency meeting DOE Level VI and CoC EPS V5 Tier 2 requirements.
  • No load power consumption is less than 0.075 W.
  • Average active efficiency is greater than 85% at 18W.
Description:

The FSP018M Series consists of AC/DC wall mount switching power supplies capable of delivering 15 to 18 watts of continuous output power. They are available with fixed North American or European AC plugs and comply with Energy Star requirements. All models meet IEC60601-1-2, EN55011, and FCC Class B emission limits.

Input Specifications:
  • Voltage: 85-264 VAC
  • Frequency: 47-63 Hz
  • Current: 0.1A (rms, 240 VAC) to 0.8A (rms, 100 VAC) at 100% loading
  • Touch current: 100 μA max. at 264 VAC, 63 Hz
Output Specifications:
  • Voltage/Current: See rating chart.
  • Maximum output power: See rating chart.
  • Ripple and noise: 1% peak to peak maximum (100 mVp-p max. for outputs below 10 V)
  • Protection: OVP (Latch off), OCP & Shorted (Auto-recovery), OTP (Latch off)
  • Temperature coefficient: ±0.04% /℃ maximum
  • Transient response: Maximum excursion of 4% or better, recovering to 1% of final value within 500 μs after a 25% step load change
Environmental Specifications:
  • Operating temperature: 0℃ to +40℃
  • Storage temperature: -20℃ to +80℃
  • Relative humidity: 10% to 90% non-condensing
General Specifications:
  • Hold-up time: 10 ms minimum at 115 VAC
  • Turn on delay time: 2 s maximum at 115 VAC
  • Efficiency: ±0.5% maximum at full load
  • Inrush current: Must not cause the input fuse to open or damage components.
  • Operation altitude: 5000 meters
  • Withstand voltage: 4000 VAC from input to output (2 MOPP), 1500 VAC from input to ground
  • MTBF: 300,000 hours at full load at 25℃ ambient, calculated per MIL-HDBK-217F
EMC Performance (IEC60601-1-2):
  • EN55011: Class B conducted, Class B radiated
  • FCC: Class B conducted, Class B radiated
  • VCCI: Class B conducted, Class B radiated
  • EN61000-3-2: Harmonic distortion, Class A
  • EN61000-3-3: Line flicker
  • EN61000-4-2: ESD, ±15 KV air and ±8 KV contact
  • EN61000-4-3: Radiated immunity, 3 V/m
  • EN61000-4-4: Fast transient/burst, ±2 KV
  • EN61000-4-5: Surge, ±1 KV diff., ±2 KV com.
  • EN61000-4-6: Conducted immunity, 6 Vrms
  • EN61000-4-8: Magnetic field immunity, 30 A/m
  • EN61000-4-11: Voltage dip immunity, 30% reduction for 500 ms, 60% reduction for 200 ms, and 100% reduction for 10 ms
Safety Standard Approval:

Complies with DOE Level VI and CoC V5 Tier 2 standards.

Mechanical Specifications:
  • Weight: Approximately 150 grams (0.33 lbs.)
See more

Catalog excerpts

FSP018M Series-1

TECHNICAL DATASHEET 15-18W Medical Power Supplies FSP018M Series FSP018M SeriesFEATURES • Wide Input voltage range 85~264Vac • High altitude 5000M operation • High efficiency compliant with DOE Level VI and CoC EPS V5 Tier 2 requirements * No load power consumption less than 0.075 W * Average active efficiency greater than 85% @ 18W Output voltage /current: Maximum output power: Ripple and noise: Temperature coefficient: Transient response: OUTPUT SPECIFICATIONS See rating chart. 1% peak to peak maximum(except 100 mVp-p max. for lower than output 10 V) Latch off Auto-recovery Latch off ±0.04% /°C maximum Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change Relative humidity: 10% to 90% non-condensing Line regulation: ±0.5% maximum at full load Inrush current: The cold inrush current must not cause the input fuse to open or cause damage to components. Operation Altitude 5000 meters Withstand voltage: 4000 VAC from input to output (2 MOPP) 1500 VAC from input to ground MTBF: 300,000 hours at full load at 25°C ambient, calculated EN55011: Class B conducted, Class B radiated FCC: Class B conducted, Class B radiated VCCI: Class B conducted, Class B radiated EN61000-3-2: Harmonic distortion, Class A EN61000-4-6: Conducted immunity, 6 Vrms EN61000-4-8: Magnetic field immunity, 30 A/m EN61000-4-11: Voltage dip immunity, 30% reduction for 500 ms, 60% © 2021 FSP Group. All Rights Reserved. All trademarks are registered to their respective owners. 2021.04 spec

 Open the catalog to page 1
FSP018M Series-2

TECHNICAL DATASHEET OUTPUT VOLTAGE/CURRENT RATING CHART Model 1. FSP018M-DxU models are with fixed North American AC plug for safety approval cULus only, and FSP018M-DxE models with fixed European AC plug for safety approval TUV & CE only. 2. Ripple and noise is maximum peak to peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 10 ^F tantalum capacitor in parallel with a 0.1 ^F ceramic capacitor across the output. © 2021 FSP Group. All Rights Reserved. All trademarks are registered to their respective owners.

 Open the catalog to page 2
FSP018M Series-3

TECHNICAL DATASHEET 15-18W Medical Power Supplies FSP018M Series MECHANICAL SPECIFICATIONS 1. FSP018M-DXE Series models NOTES: 1. Dimensions shown in mm 2. Tolerance 1 maximum Weight: 150 grams (0.33 lbs.) approx. © 2021 FSP Group. All Rights Reserved. All trademarks are registered to their respective owners. 2021.04 spec