MEASURE. ANALYZE. CONTROL. Product Specification Sheet Online Trace Oxygen Analyzer w/ Integral Sample System 0 - 1 PPM Low Range; 0 - 25% High Range Resolution of 0.001 Parts-Per-Million Oxygen Integral Sample System w/ Bypass Valve Bi-Directional Communication Link Extensive Electronic Features & Outputs Panel Mount Configuration Electrochemical Sensor Technology The OMD-677 is designed to measure trace oxygen in the sub 1 ppm region. The unit combines an advanced set of electronic features with our, industry leading, precision electrochemical oxygen sensor technology. The result is a highly reliable and cost effective design with easy-to-use user interface. The analyzer comes with a 0 - 1 PPM full scale low range with a resolution of 0.001 ppm. The analyzer can also be configured for 0 - 1 ppm, 0 - 10ppm, 0 - 100ppm, 0 - 1000ppm and 0 - 25% in autorange or manual-range mode. The analyzer offers the user 2 different digital communication options, both of which are bi-directional. This comes in the form of MODBUS RS485 ASCII or RS232. Alarm functionality comes in the way of 2 fully adjustable form C non-latching relay contacts. These can be configured as NO or NC and can be set as HIGH or LOW with optional delay mode. A power failure alarm is also standard and comes as a form C nonlatching relay contact. The oxygen sensor used in the OMD-677 is based on the galvanic electrochemical fuel cell principal. All oxygen sensors are manufactured in house by Southland Sensing Ltd. under a strict quality program. The standard cell (TO2-133T) is unaffected by other background gases such as H2, He, or Hydrocarbons. The optional acidic cell (TO2-233T) works well when acid gases such as CO2 or Natural Gas are present. The sensors are self-contained and minimal maintenance is required -no need to clean electrodes or add electrolyte. Applications: Specifications Accuracy: Alarms: Analysis Range: Calibration: Communication: Dimensions: Display: Enclosure: Flow Sensitivity: Gas Connections: Output (Analog): Power: Pressure: Range ID: Response Time: Sample System: Air Liquefaction and Separation Pure, Gaseous Hydrocarbon Stream Monitoring Gas Purity Certification Process Monitoring of Gaseous Monomers Semiconductor Manufacturing Protective Atmosphere Blanketing of Feedstock Sensor: Sensor Life: Temperature: Temperature Compensation: Warranty: Weight: < +/- 1% of Full Scale Range* (2) Adjustable Relay Contacts (1) Power Fail Relay Contact 0-1/10/100/1000ppm/25% Periodically Bi-Directional RS232 MODBUS RS485 ASCII 10.78 x 7.47 x 7.75 inch Large with Backlight Brushed Stainless Steel 0.5 - 5 SCFH 1/8" Compression Tube 0 - 1V DC, 0 - 10V DC Isolated 4 - 20mA 100 - 240 VAC Inlet, 0 - 50 PSIG 4 - 20 mA analog output 0 - 1 V DC analog output T90in 10 Seconds Flow Control, 4-way sample / Bypass Valve, Flow Indicator TO2-133T Trace O2 Sensor 20 - 25 months 0 - 50 deg C Digital 12 months Analyzer & Sensor 12.0 lbs *Accuracy at constant conditions Direct Fit Field Replacement: Designed to replace competitive analyzers: Teledyne: 3000TA, 3000TA-XL AII: GPR-1600, GPR-1600MS, PI2-MS-1000 Designed, Tested and Assembled in California, USA 4045 E. Guasti Rd. #203 Ontario, CA 91761 USA : 1-949-398-2879 : [email protected] : www.sso2.com

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.