OMD-675 Online Trace Oxygen Analyzer
1 /1Page

OMD-675 Online Trace Oxygen Analyzer

OMD-675 Online Trace Oxygen Analyzer
1 /1Page

Catalog excerpts

OMD-675 Online Trace Oxygen Analyzer-1

OMD-675 Oxygen Analyzer Product Specification Sheet Online Trace Oxygen Analyzer w/ Integral Sample System 0 - 1 PPM Low Range; 0 - 25% High Range Resolution of 0.001 Parts-Per-Million Oxygen Integral Sample System w/ Bypass Valve Bi-Directional Communication Link Extensive Electronic Features & Outputs 19” Rack Mount Configuration Electrochemical Sensor Technology The OMD-675 is designed to measure trace oxygen in the sub 1 ppm region. The unit combines an advanced set of electronic features with our industry leading precision electrochemical oxygen sensor technology. The result is a highly reliable and cost effective design with an easy-to-use user interface. The analyzer comes with a 0 - 1 PPM full scale low range with a resolution of 0.001 ppm. The analyzer can also be configured for 0 - 1 ppm, 0 - 10ppm, 0 - 100ppm, 0 - 1000ppm and 0 - 25% in autorange or manual-range mode. The analyzer offers the user 2 different digital communication options, both of which are bi-directional. These come in the form of MODBUS RS485 ASCII or RS232. Alarm functionality comes in the way of 2 fully adjustable form C non-latching relay contacts. These can be configured as NO or NC and can be set as HIGH or LOW with optional delay mode. A power failure alarm is also standard and comes as a form C non-latching relay contact. The oxygen sensor used in the OMD-675 is based on the galvanic electrochemical fuel cell principal. All oxygen sensors are manufactured in house by Southland Sensing Ltd. under a strict quality program. The standard cell (TO2-133T) is unaffected by other background gases such as H2, He, or Hydrocarbons. The optional acidic cell (TO2-233T) works well when acid gases such as CO2 or Natural Gas are present. The sensors are self-contained and minimal maintenance is required no need to clean electrodes or add electrolyte. Applications: Air Liquefaction and Separation Pure, Gaseous Hydrocarbon Stream Monitoring Gas Purity Certification Process Monitoring of Gaseous Monomers Semiconductor Manufacturing Protective Atmosphere Blanketing of Feedstock Specifications Accuracy: < +/- 1% of Full Scale Range* Alarms: (2) Adjustable Relay Contacts (1) Power Fail Relay Contact Analysis Range: 0-1/10/100/1000ppm/25% Calibration: Periodically Communication: Bi-Directional RS232 MODBUS RS485 ASCII Dimensions: 19.0 x 5.125 x 7.75 inch Display: Large with Backlight Enclosure: Brushed Stainless Steel Flow Sensitivity: 0.5 - 5 SCFH Gas Connections: 1/8” Compression Tube Output (Analog): 0 - 1V DC, 0 - 10V DC Isolated 4 - 20mA Power: 100 - 240 VAC Pressure: Inlet, 0 - 50 PSIG Range ID: 4 - 20 mA analog output 0 - 1 V DC analog output Response Time: T90 in 10 Seconds Sample System: Flow Control, 4-way sample / Bypass Valve, Flow Indicator Sensor: TO2-133T Trace O2 Sensor Sensor Life: 20 - 25 months Temperature: 0 - 50 deg C Temperature Compensation: Digital Warranty: 12 months Analyzer & Sensor Weight: 13.0 lbs *Accuracy at constant conditions Optional: Panel Mount Oxygen Configuration (OMD-677) [Dimensions: 10.78 x 7.47 x7.75 inch] TO2-233T Oxygen Sensor (for use in CO2) Designed, Tested, and Assembled in California, USA

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.