Manual ST2829 LCR Meter Series
119Pages

{{requestButtons}}

Catalog excerpts

Manual ST2829 LCR Meter Series - 1

SOURCETRONIC − Qualitäts-Elektronik für Service, Labor und Produktion

Open the catalog to page 1
Manual ST2829 LCR Meter Series - 2

ST2829 Series Operation Manual

Open the catalog to page 2
Manual ST2829 LCR Meter Series - 3

ST2829 Series Operation Manual

Open the catalog to page 3
Manual ST2829 LCR Meter Series - 4

ST2829 Series Operation Manual

Open the catalog to page 4
Manual ST2829 LCR Meter Series - 5

ST2829 Series Operation Manual

Open the catalog to page 5
Manual ST2829 LCR Meter Series - 6

ST2829 Series Operation Manual Announcement The description of the manual may not cover all contents of the instrument, and our company is subject to change and to improve the performance, function, inner structure, appearance, accessory and package of the instrument without notice. If there is puzzle caused by inconsistency of manual and instrument, then you can contact with our company by the address on the cover.

Open the catalog to page 6
Manual ST2829 LCR Meter Series - 7

ST2829 Series Operation Manual When you receive the instrument, some inspections are necessary, and the condition must be understood and available before installing the instrument. 1.1 To Inspect the package Inspect the shipping container for damage after unpacking it. It is not recommended to power on the instrument in the case of a damaged container. If the contents in the container do not conform to the packing list, notify us or your dealer. 1.2 Power connection 1) Power-supplying voltage range: 100~120Vac or 198~242Vac. Being related with the power setup on the rear panel. 2)...

Open the catalog to page 7
Manual ST2829 LCR Meter Series - 8

ST2829 Series Operation Manual 1.4 Environment 1) Please do not operate the instrument in the place that is vibrative, dusty, under direct sunlight or where there is corrosive air. 2) The normal working temperature is 0℃ ~40℃ relative humidity ≤75%, so the , instrument should be used under above condition to guarantee the accuracy. 3) There is heat abstractor on the rear panel to avoid the inner temperature rising. In order to keep good airiness, please don’t obstruct the left and right airiness holes to make the instrument maintain the accuracy. 4) Although the instrument has been...

Open the catalog to page 8
Manual ST2829 LCR Meter Series - 9

ST2829 Series Operation Manual 2) Dimension (W*H*D): 430mm*185mm*473mm 3) Weight: About 13kg.

Open the catalog to page 9
Manual ST2829 LCR Meter Series - 10

ST2829 Series Operation Manual In this chapter, the basic operation features of ST2829 series are described. Please read the content carefully before using ST2829 series instruments, thus you can learn the operation of ST2829. ST2829 series instrument includes ST2829A, ST2829B and ST2829C. There frequency ranges are respectively 20Hz-300KHz, 20Hz-500KHz and 20Hz-1MHz. This manual takes ST2829A for example to describe the basic operation of T2829 series. 2.1 Introduction to front panel Figure 2-1 shows the front panel of ST2829. 1 2 3 4 MENU DISP UNKNOWN LCUR 1) USB HOST interface Connect U...

Open the catalog to page 10
Manual ST2829 LCR Meter Series - 11

ST2829 Series Operation Manual 6) LCD 800*480 colorful TFT LCD displays measurement results and conditions. 7) [COPY] Copy the currently displayed page to USB memory. 8) [DISP] Press this key to enter into the corresponding measurement display page of instrument functions. 9) [SETUP] Press this key to enter into the corresponding measurement setup page of instrument functions. 10) [SYSTEM] Press this key to enter into the system setup page. 11) Numerical keys These keys are used to input data to the instrument. The key consists of numerical keys [0] to [9], decimal point [.] and [+/-] key....

Open the catalog to page 11
Manual ST2829 LCR Meter Series - 12

ST2829 Series Operation Manual 22) Knob for menu selection and numeric input This knob is used to move the cursor, select and set parameters. 23) Confirmation key This key is used to end the data input, confirm and save the data input through knob. 24) Ground terminal The ground terminal is connected with the case of instrument, which can be used to protect or shield the ground connection. 25) File Press this key to enter into the file manage system. 26) Soft keys Six soft keys are used to select parameters. The corresponding function of each soft key has been displayed on its left (the...

Open the catalog to page 12
Manual ST2829 LCR Meter Series - 13

ST2829 Series Operation Manual 6) IEEE-488 interface The tester can communicate with PC through GPIB interface. 7) RS232 interface Series communication interface can realize the communication with PC. 8) Fan window Heat elimination, maintaining the normal working temperature 9) Power socket Input AC power. 10) Fuse base Being used to install power fuse, protect instrument, and switch 110V/220V by changing the direction of core. ——————————————————————————————————————— Warning: Be sure that the direction of fuse is accordant with power-supply voltage range before charging....

Open the catalog to page 13
Manual ST2829 LCR Meter Series - 14

ST2829 Series Operation Manual 1) Display page name Indicate the name of the currently displayed page. 2) Soft keys The zone is used to display the function definition of soft key. The definition of soft key can be different as the difference of cursor’s direction in the zone. 3) Test result/ condition display zone In this zone, test result information and current condition are displayed. 4) Help In this zone, information about system and user data input is displayed. 2.4 Main menu keys and corresponding displayed pages 2.4.1 [DISP] When the LCR function is active, press this key-[DISP] to...

Open the catalog to page 14
Manual ST2829 LCR Meter Series - 15

ST2829 Series Operation Manual 2.5 Basic Operation Basic operation of ST2829 is as follows:  Use menu keys ([DISP], SETUP], [SYSTEM]) and soft keys to select the desired page.  Use cursor keys ([←][→]) and the slide switch to move the cursor to the desired zone. When the cursor moves to a specified zone, the zone will become reverse expression. The soft key functions corresponding to the current zone of the cursor will be displayed in the soft key zone. Users can select and use the desired key. Numeric keys, [BACKSPACE] and [ENTER] are used to input data. When a numeric key is pressed...

Open the catalog to page 15
Manual ST2829 LCR Meter Series - 16

ST2829 Series Operation Manual If the password protection function is on, users are required to input the password and then press [ENTER] to enter into the page of main menu. ——————————————————————————————————————— Note: The instrument has a default password-2829. In your practical use, you can change it

Open the catalog to page 16