Rotoblock
40Pages

{{requestButtons}}

Catalog excerpts

Rotoblock - 1

housed units SS series housed units T series housed units S series @ sonzogni camme via venezia 658 - 24045 fara d’adda bg italy tel. +39 0363 368511 - telefax +39 0363 61511 - sonzogni@sonzogni.it

Open the catalog to page 1
Rotoblock - 2

rotoblock il divisore a stazioni SC 2020.3 Catalogue LegendSymbol Description Unit n P Code Ms Mu Mpa Rs Cv Ca Cp kf number of stations index angle code for ordering static output torque supplied torque at 50, 100, 200 and 400 cycles/min. for a life of 8000 hours static torque required to move the output ( turret + output shaft ) at 100 cycles/min. turret radius coefficient of speed coefficient of acceleration coefficient of profile coefficient of shape (number of positionings of the output shaft for every round of the input shaft) Warning The indicated values of "Mu" on this catalogue are...

Open the catalog to page 2
Rotoblock - 3

SC 2020.3 Catalogue housed units S series n 1 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 3
Rotoblock - 4

SC 2020.3 Catalogue housed units S series n 2 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 4
Rotoblock - 5

SC 2020.3 Catalogue housed units S series n 3 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 5
Rotoblock - 6

SC 2020.3 Catalogue housed units S series n 4 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 6
Rotoblock - 7

SC 2020.3 Catalogue housed units S series n 5 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 7
Rotoblock - 8

SC 2020.3 Catalogue housed units S series n 6 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 8
Rotoblock - 9

SC 2020.3 Catalogue housed units S series n 8 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 9
Rotoblock - 10

SC 2020.3 Catalogue housed units S series n 10 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 10
Rotoblock - 11

SC 2020.3 Catalogue housed units S series n 12 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 11
Rotoblock - 12

SC 2020.3 Catalogue housed units S series n * The units with ”kf = 2” make two positionings of the output shaft for every revolution of the input shaft 16 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 12
Rotoblock - 13

housed units S series * The units with ”kf = 2” make two positionings of the output shaft for every revolution of the input shaft 20 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 13
Rotoblock - 14

SC 2020.3 Catalogue housed units S series n * The units with ”kf = 2” make two positionings of the output shaft for every revolution of the input shaft 24 stops @ SONZOGNI CAMME spa

Open the catalog to page 14
Rotoblock - 15

SC 2020.3 Catalogue housed units SS series n 1 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 15
Rotoblock - 16

housed units SS series

Open the catalog to page 16
Rotoblock - 17

SC 2020.3 Catalogue housed units SS series n 2 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 17
Rotoblock - 18

SC 2020.3 Catalogue housed units SS series n 3 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 18
Rotoblock - 19

SC 2020.3 Catalogue housed units SS series n 4 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 19
Rotoblock - 20

SC 2020.3 Catalogue housed units SS series n 5 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 20
Rotoblock - 21

SC 2020.3 Catalogue housed units SS series n 6 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 21
Rotoblock - 22

SC 2020.3 Catalogue housed units SS series n 8 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 22
Rotoblock - 23

SC 2020.3 Catalogue housed units SS series n 10 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 23
Rotoblock - 24

SC 2020.3 Catalogue housed units SS series n 12 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 24
Rotoblock - 25

SC 2020.3 Catalogue housed units SS series n * The units with ”kf = 2” make two positionings of the output shaft for every revolution of the input shaft 16 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 25
Rotoblock - 26

housed units SS series * The units with ”kf = 2” make two positionings of the output shaft for every revolution of the input shaft 20 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 26
Rotoblock - 27

SC 2020.3 Catalogue housed units SS series n * The units with ”kf = 2” make two positionings of the output shaft for every revolution of the input shaft 24 stops @ SONZOGNI CAMME spa

Open the catalog to page 27
Rotoblock - 28

SC 2020.3 Catalogue housed units T series n 1 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 28
Rotoblock - 29

housed units T series

Open the catalog to page 29
Rotoblock - 30

SC 2020.3 Catalogue housed units T series n 2 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 30
Rotoblock - 31

SC 2020.3 Catalogue housed units T series n 3 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 31
Rotoblock - 32

SC 2020.3 Catalogue housed units T series n 4 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 32
Rotoblock - 33

SC 2020.3 Catalogue housed units T series n 5 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 33
Rotoblock - 34

SC 2020.3 Catalogue housed units T series n 6 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 34
Rotoblock - 35

SC 2020.3 Catalogue housed units T series n 8 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 35
Rotoblock - 36

SC 2020.3 Catalogue housed units T series n 10 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 36
Rotoblock - 37

SC 2020.3 Catalogue housed units T series n 12 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 37
Rotoblock - 38

SC 2020.3 Catalogue housed units T series n * The units with ”kf = 2” make two positionings of the output shaft for every revolution of the input shaft 16 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 38
Rotoblock - 39

housed units T series * The units with ”kf = 2” make two positionings of the output shaft for every revolution of the input shaft 20 STOPS @ SONZOGNI CAMME spa

Open the catalog to page 39
Rotoblock - 40

SC 2020.3 Catalogue housed units T series n * The units with ”kf = 2” make two positionings of the output shaft for every revolution of the input shaft 24 stops @ SONZOGNI CAMME spa

Open the catalog to page 40

All Sonzogni Camme catalogs and technical brochures