video corpo

DP-10 2021

DP-10 2021

DP-10 2021

Product catalog summary
Overview
The DP-10 Densimetry Sensor is designed for measuring the density of liquid de-icing agents such as NaCl, CaCl, and MgCl in water during brine production. It is particularly useful for winter road services, brine stations, and salt mixing stations, offering real-time measurement capabilities.

Features and Advantages
  • Real-time measurement for process conditions.
  • Facilitates automated mixing processes.
  • Available in different versions to meet various requirements.
  • Robust construction suitable for demanding environments.
  • Easy to install and operate.

Technical Specifications
  • Measuring Range: 1.000 – 1.400 g/cm³ with a resolution of 0.001 g/cm³.
  • Measurement Principle: Oscillating U-tube principle.
  • Functions: Determines concentration of NaCl, CaCl, MgCl in water.
  • Interface (Analogue): Signal 0 ... 10 V for concentration and specific density.
  • Interface (Digital): RS 232 service-interface with a transfer rate of 9.6 kBd.
  • Power Supply: 20 ... 30 V DC/AC, 80 mA consumption.
  • Operating Temperature: -25 °C to +50 °C; Medium Temperature: -30 °C to +30 °C.
  • Housing: Stainless steel, dimensions 150 x 340 x 100 mm, weight approx. 2 kg, IP 65 protection.

Variants
  • DP-10/A: Includes an integrated LED-display for concentration and temperature.
  • DP-10/MR: Features a mixing controller with a PID controller and relay outputs for mixing valve and status.

Contact Information
Sommer Messtechnik, Strassenhaeuser 27, A-6842 Koblach, Phone: +43(0)5523-55989, Email: [email protected], Website: www.sommer.at
See more

Catalog excerpts

DP-10 2021-1

Density measurement of liquid de-icing agents NaCl, CaCl and MgCl in water during brine production Liquid de-icing agents are considered to be the ideal solution to cope with icy roads since a long time. The density meter DP-10 was especially developed for the requirements of winter road services when it comes to mixing the brine. Further fields of application are brine stations and salt mixing stations. Other than the conventional, manual density measurement using a spindle, it‘s the DP-10‘s advantage that - via a bypass - the measurement can be done in process condition and therefore in real-time. Choose the suitable measuring device according to your individual needs: The standard version with analogue output for further data processing, an enhanced version with internal LEDdisplay (DP-10/A) or the system solution with integrated mixing controller and LED-display (DP-10/MR). Features and Advantages 99 Real-time measurement 99 Device facilitates automated mixing processes 99 Different, suitable system for all requirements 99 Robust construction for applications in demanding environmental conditions 99 Easy installation and operatio

 Open the catalog to page 1
DP-10 2021-2

Technical Data DP-10 Measuring range density Range: 1.000 – 1.400 g/cm³; resolution: 0.001 g/cm³ Measurement principle: oscillating U-tube principle determination of concentration of NaCl, CaCl, MgCl in water (switchable for NaCl, CaCl and MgCl) Interface (analogue) Concentration, specific density Signal: 0 ... 10 V (equals to: 15.0 ... 25.00 % NaCl; 12.5 ... 37.5 % CaCl; 12.5 ... 37.5 % MgCl) Interface (digital) Service-interface RS 232 (concentration, specific density) Transfer rate: 9.6 kBd Protocol: ASCII Power supply Supply voltage 20 ... 30 V DC/AC Power consumption: 80 mA Operation temperature...

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.