Overview
The DFM 433 series, including DFM 433, DFM-E 433, and DFM-EA 433, are radio data transmission modules designed for practical data transmission via radio networks. These devices facilitate the connection of measurement points to central data acquisition systems, offering a cost-effective alternative to traditional cabling.

Features and Advantages
  • Autonomous radio network setup without the need for radio allowance.
  • Plug & Play capability for direct sensor connection.
  • Replaces cables for transmitting analog or digital signals.
  • Serial data transmission without protocol complexity.
  • Low energy consumption, ideal for solar power.
  • Compact and energy-autonomous design, suitable for upgrades.

Fields of Application
The DFM modules are versatile, suitable for transmitting data from water level measurements, wind sensors, and weather stations to central data systems. They support repeater mode for extended range and challenging terrains.

Implementation
DFM devices offer flexibility with analog, digital, and serial inputs/outputs. They operate in transparent radio mode for seamless serial data transmission. Typically powered by solar panels, they are installed on top-hat rails in switch cabinets.

Technical Details
  • DFM 433: 1 x RS 232 serial interface for both input and output.
  • DFM-E 433: Multiple interfaces including RS 232, analog (4-20 mA, 0-2.5 V), and digital (frequency, counter).
  • DFM-EA 433: Similar to DFM-E 433 but with additional analog output interfaces.
See more

Catalog excerpts

DFM 433 - Radio Data Transmission Modules-1

Radio Data Transmission Modules DFM 433 Practical data transmission via radio network The radio devices of the DFM family (DFM 433, DFM-E 433, DFM-EA 433) allow an easy setup of radio paths for the connection of measuring spots to a central data acquisition. They can also be used as a cost efficient alternative instead of a complicated cable setting for example in between the sensor and the data collection station (e.g. water level station). Features and advantages • Setup of autonomous radio networks • No radio allowance necessary • Plug & Play - direct connection of the sensors to DFM • Replacement for cable - input, transmission and output of analogue or digital measuring signals • Serial data transmission without additional effort for protocol • Minimal energy consumption - optimal for solar powered energy supply • Mechanically compact and energy autonomous radio solution - also optimal as upgrade Fields of application As a replacement for cables, the DFM can do the transmission of the measuring data for example of a water level or a discharge measurement from the bridge to the switch cabinet. Similarly the measuring data of wind speed and direction of a wind sensor on a supporting mast of a ski lift can be transmitted to the bottom station. Another example would be the radio data transmission from several automatic weather stations spread over an area to the central data acquisition. For even farther measuring stations, or when unsuitable landforms (mountains) interfere, the measuring data are transmitted over existing stations to the central station (repeater mode). Therefore, the establishment of whole radio networks is possible. Implementation With the analogue, digital and serial inputs and outputs the DFM radio devices are highly flexible when it comes to data transmission. For uncomplicated data transmission via serial interface the DFM operates in the transparent radio mode. The data input over the serial interface is received without additional effort for the protocol or command.A solar power panel mostly supplies sensor and radio device, the DFM is usually installed on a top-hat rail in a switch cabinet. Sommer Messtechnik I www.sommer.at I [email protected]

 Open the catalog to page 1
DFM 433 - Radio Data Transmission Modules-2

• Input 1 x serial interface RS 232 • Output 1 x serial interface RS 232 DFM-E 433 * Input • 1 x serial interface RS 232 • 3 x analogue interface 4 ... 20 mA, 0 ... 2.5 V • 1 x digital interface frequency 1 ... 1000 Hz • 1 x digital interface: counter, state on/off • Output • 1 x serial interface RS 232 • 1 x analogue interface 4 ... 20 mA, 0 ... 2.5 V • 1 x digital interface: switch DFM-EA 433 * Input • 1 x serial interface RS 232 • 3 x analogue interface 4 ... 20 mA, 0 ... 2.5 V • 1 x digital interface frequency 1 ... 1000 Hz • 1 x digital interface: counter, state on/off • Output • 1 x serial...

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.