St d d Furnaces & O Standard F Ovens since 1918 Fixed crucible melting furnace 1200°C Definition: Fixed crucible furnace for melting or holding the melted state of non-ferrous metals. Construction: Access to crucible from top, manual cover closing. Insulation: Multilayer insulation. Interior in ceramic fibre and refractory bricks. Heating: Electrical coil resistors all around the crucible. Resistors mounted on ceramic tubes. Electricity: 3x400 VAC, 50 Hz. Independent electric control box to mount on a wall. Regulation: Thermocouple outside of crucible. Axron Swiss PID temperature controller. Documentation: CE marking and operating instructions in English. Photos for illustration purposes only ITEM CODE