video corpo

PROTOCOL INTERFACE MODULE (PIM)
9Pages

{{requestButtons}}

Catalog excerpts

PROTOCOL INTERFACE MODULE (PIM) - 1

ULTRA PRECISION TECHNOLOGIES Solartron Metrology Precision Driven Connect Solartron’s Orbit® Network to the world’s leading PLC protocols Etheri WIP BB0BO SWBsSa EtherCAf Modbus DESCRIPTION Solartron Metrology’s Protocol Interface Module (PIM) provides a simple way of interfacing the Orbit® Digital Measuring Network to most Programmable Logic Controllers (PLCs). A distinct PIM is created for each protocol, including: > Ethernet/IP™ > ProfiNet ™ > EtherCat ™ > Modbus TCP > MODBUS RTU (RS485 Serial) can be interfaced using Solartron’s standard MODIM Interface. (PSIM required) The PIM includes the following features: > Communicate with up to 150 Orbit modules with Explicit Messaging or 50 with Cyclic Messaging > Power up to 10 Orbit modules (depending on type). (A PSIM can be used when more than 10 is required) > Connect any Solartron Digital sensor including lasers > Connect 3rd party sensors via the Analog Interface Module (AIM) > Set up via free software interface

Open the catalog to page 1
PROTOCOL INTERFACE MODULE (PIM) - 2

Solartron Metrology VMETEK ULTRA PRECISION TECHNOLOGIES PIM PLC Interface to Orbit PLC General Protocol Specifications Explicit and Cyclic Messaging Supported 125 word read and write data length Ethen 'et/IP > One of the primary connectivity tools to different Rockwell Automation platforms, or any other PC’s that support EtherNet/IP™ > Explicit Messaging aspect of the protocol has been implemented for reading and setting individual parameters, > Cyclic messaging has been implemented to facilitate synchronised readings > Ethernet I/P Server Mode: In server mode, the module accepts commands...

Open the catalog to page 2
PROTOCOL INTERFACE MODULE (PIM) - 3

AMETEK ULTRA PRECISION TECHNOLOGIES PIM PLC Interface to Orbit (cont.) / i Solartron •/ Metrology Precision Driven amSaa > One of the primary connectivity tools to different Siemens platforms or any other devices that support ProfiNet®. > The Explicit Messaging aspect of the protocol has been implemented for reading and setting individual parameters, cyclic messaging has been implemented to facilitate synchronised readings EtherCAf ^ > EtherCAT is the open real-time Ethernet network originally developed by Beckhoff. > The EtherCAT variant of the PIM provides both Explicit and Implicit data...

Open the catalog to page 3
PROTOCOL INTERFACE MODULE (PIM) - 4

Solartron Metrology Precision Driven > Download Orbit Support Pack for Windows > Stack Orbit Modules to PIM > Plug PIM to Comuter using MicroUSB to USB Cord (Included) > Set up Orbit and Protocol Parameters Configure output to PLC > Set EtherNet/IP™ , PROFINET®, EtherCat settings such as DHCP enable, host name, IP address, subnet mask and default gateway. > For PROFINET this can also be done through the standard PROFINET methods - TIA portal, Pronetta). > The configuration application is also used to set Modbus settings such as baud rate, parity, Modbus address etc. Configure Solartron...

Open the catalog to page 4
PROTOCOL INTERFACE MODULE (PIM) - 5

AMETEK ULTRA PRECISION TECHNOLOGIES Solartron Metrology Precision DrivenSample Application Inline Flatness check www.solartronmetrology.com • sales.solartronmetrology@ametek.com EDCR number: 20860 Issue number: 2 Datasheet number: 503178

Open the catalog to page 5
PROTOCOL INTERFACE MODULE (PIM) - 6

ULTRA PRECISION TECHNOLOGIES Solartron Metrology Precision Driven Sample Application Pim being used with 2 digital probes to measure diameter and an AIM module to check ambient temperature www.solartronmetrology.com • sales.solartronmetrology@ametek.com EDCR number: 20860 Issue number: 2 Datasheet number: 503178

Open the catalog to page 6
PROTOCOL INTERFACE MODULE (PIM) - 7

Solartron Metrology Precision Driven Product Environmental Sealing Storage Temperature (°C) Operating Temperature (°C) EMC Emissions EMC Immunity EMC Immunity Shock Material PIM Interface Protocol Messaging Types Ethernet/IP Server Specifications Connections CIP Services Supported Reading Rate (Readings per second) Power (input) No of Orbit Modules (powered) No of Orbit Modules using additonal Power Supply Display Electrical Interface Ethernet/IP IP43 0 to +60 +5 to +60 EN61000-6-3 EN61000-6-2 EN 61326-1:2013 Do not subject to excessive shocks or loads ABS, Nylon, Acrylic Ethernet/IP...

Open the catalog to page 7
PROTOCOL INTERFACE MODULE (PIM) - 8

Solartron Metrology Precision Driven AMETEK ULTRA PRECISION TECHNOLOGIES Accessories +24V Power Block with Mains leads. Available with UK, EU and US plugs Spare T-con Mounts Spare Earthing/Mounting brackets Note: MODIM dimensions are the same as a Standard PIE module (see catalogue) DIGITAL NETWORK The Solartron Orbit® 3 Digital Measurement System, in conjunction with Solartron’s wide range of transducers, provides a limitless set of measuring system solutions, with numerous different interfaces to computers and PLC’s, making Orbit® 3 completely flexible. Compatible products include both...

Open the catalog to page 8
PROTOCOL INTERFACE MODULE (PIM) - 9

ULTRA PRECISION TECHNOLOGIES Solartron Metrology Sales Offices UK (Headquarters and Factory) Solartron Metrology Bognor Regis. West Sussex. P022 9ST Tel +44 (0) 1243 833 333 Fax. +44 (0) 1243 833 332 Email: sales solartronmetrologyaameiek.com AMETEK Commercial Enterprise (Shanghai) Co. Ltd Shanghai. 200131, China Tel *86 21 5763 2509 Email: chlnaiolartronmetrologyaametek com Solartron Metrology USA Central Sales Office Gastonia. NC 28054 Tel: +1800 873 5838 Email usasales.sotartronmetrologypametek.ccKn AMETEK GmbH Solartron Metrology Division 40670 Meerbusch Tet +49 (0) 2159 9136 500 Fax:...