ModuLab XM ECS
8Pages

{{requestButtons}}

Catalog excerpts

ModuLab XM ECS - 2

Market leading impedance analysis Widest voltage and current range available Anode/Cathode and Stack Testing ModuLab® XM ECS is an Xtreme Measurement electrochemical test system that is capable of measuring micro-ohm impedance cells (latest generation batteries and fuel cells, for example), while able to accurately characterize corrosion coatings at the other extreme. The system uses a unique AC calibration method that ensures ultimate accuracy in all cases. Each system is independently calibrated, ensuring the accuracy of your results. The system makes use of ultra-fast sample rate digital...

Open the catalog to page 2
ModuLab XM ECS - 3

The ModuLab XM ECS is able to make very accurate, extreme low impedance measurements in the micro- ohm region using a wide range of internal and external power boosters. These example plots show the quality of 10 uohm and 100 uohm data that is available from Control and Slave Modules The ModuLab XM system has two 'intelligent' Control ■ XM PSTAT 1 MS/s for time domain control In addition there are several Slave Modules that amplify the signals produced by the Control Modules to provide high voltage/current polarization waveforms to the sample, and provide amplified/attenuated high...

Open the catalog to page 3
ModuLab XM ECS - 4

Potentiostat / Galvanostat XM PSTAT 1 Ms/s makes use of the latest high technology hardware for accurate waveform generation and fast data acquisition. Fast auto-sequencing between CV, pulse and all types of potentiostatic/galvanostatic techniques Frequency Response Analyzer XM FRA 1 MHz / 300 KHz are the most versatile Frequency Response Analyzers available today, and are fully compatible with all XM slave modules for high voltage, high/low current, and impedance measurements of anodes/cathodes and complete cells in a battery/fuel cell stack. Multi-sine / Fast Fourier Transform (FFT)...

Open the catalog to page 4
ModuLab XM ECS - 5

Xtreme Measurement XM slave modules PhotoEchem Option Range of Frequency and Time Domain Measurement techniques including IMPS, IMVS, Impedance, PhotoVoltage Decay, Charge Extraction techniques, I-V ‘Auto’ analysis of data enabled for calculation of effective Diffusion coefficients and Electron Lifetimes High Voltage Options XM HV 100 / 30 high voltage amplifier options extend the XM PSTAT’s voltage range to 100 V/30 V for testing fuel cell stacks, battery stacks or other high voltage cells: Provides applied cell polarization and compliance at up to 100 V or 30 V Low current amplifier...

Open the catalog to page 5
ModuLab XM ECS - 6

A wide range of accessories are available for use with the ModuLab XM ECS, including: Dye-Sensitized Solar Cells (DSSC) - Optical Bench ModuLab XM DSSC is a fully integrated photoelectrochemical measurement system designed for the characterization of Dye-Sensitzed Solar Cells (refer to separate brochure for more details). • Range of Frequency and Time domain Measurement techniques including IMPS, IMVS, Impedance, PhotoVoltage Decay, Charge Extraction Techniques, I-V ‘Auto’ analysis of data enabled for calculation of effective diffusion coefficients and electron lifetimes at one click of a...

Open the catalog to page 6
ModuLab XM ECS - 7

Xtreme Measurement Specifications Control Module Slave Modules Potentiostat General Slots taken High Voltage Internal Booster Cell connections Instrument Connections Floating measurements Impedance measurement bandwidth Maximum ADC sample rate Smooth scan generator Maximum time record DC scan rate (potentiostatic) DC scan rate (galvanostatic) Minimum pulse duration Voltage polarization range Current polarization range Maximum compliance (CE vs. LO) Bandwidth (decade steps) Polarization V/I error (setting+range) Slew rate Reference Inputs (RE) Connections Differential input Differential...

Open the catalog to page 7
ModuLab XM ECS - 8

FRA Specifications Frequency Response Analyzer Maximum sample rate Frequency range - FRA 1 MHz - FRA 300 kHz Frequency resolution Frequency error Minimum ∫ time per measurement (single sine, FFT or harmonic) Signal Output Single sine, multi-sine Single Sine Linear / logarithmic Multi-sine / harmonic frequencies Analysis channels Accuracy (ratio) Anti-alias, digital filters, DC bias reject Analysis channels Analysis modes: Single sine, FFT, harmonic System Impedance Accuracy PSTAT Impedance Accuracy Impedance accuracy specification for PSTAT, Femto Ammeter and 2A Booster combined. Impedance...

Open the catalog to page 8

All Solartron Analytical catalogs and technical brochures

  1. SolarLab

    8 Pages

  2. EchemLab

    8 Pages

  3. EnergyLab

    8 Pages

  4. MODEL 1296A

    2 Pages

  5. MODEL 1260A

    2 Pages

  6. MODEL 1280C

    2 Pages

  7. MODEL 1287A

    2 Pages

  8. 1470E

    8 Pages

  9. ModuLab-MTS

    7 Pages

Archived catalogs

  1. MODEL 1294A

    4 Pages

  2. 1254A

    2 Pages

  3. zplotcorr

    2 Pages

  4. 129610A

    2 Pages

  5. 12962

    2 Pages

  6. 1296

    2 Pages

  7. 1294bio

    4 Pages

  8. 1294

    4 Pages

  9. 1287

    2 Pages

  10. 1285

    4 Pages

  11. 1281

    2 Pages

  12. 1260

    2 Pages

  13. 1255b

    2 Pages

  14. 1255a

    2 Pages

  15. 1252a

    2 Pages

  16. 1250

    2 Pages

  17. materials

    4 Pages

  18. ModuLabSystem

    12 Pages