1294bio
4Pages

{{requestButtons}}

Catalog excerpts

1294bio - 2

Wide measurement range 1 V, 1pA sensitivity Electrical Bio-impedance is a well-proven, powerful technique for analyzing a widerange of ionic and charge transfer processes in bio-materials (see Applications).Until now, the use of impedance in bio-material applications has been limited by anumber of factors, such as the ability to measure accurately the very low currents involved, and the need for safe working when performing experiments on living tissue.The new 1294 Impedance Interface has been designed specifically to overcomethese difficulties, and to meet the present and future needs of...

Open the catalog to page 2
1294bio - 3

Rear connection:single BNCMaximum output:300mV rmsOutput resistance:50 PC control connections Ω to 1294:Parallel interface to FRA:IEEE488 interface 1294 measurement connections PC Software to FRA:Gen, V1 Hi, V1 Lo, V2 Hi to sample:Normal:4-terminal connectionsIEC601:4-terminal connections Provides control of FRA, 1294 and optional temperature controller. Result parameters:Z*, Y*, E*, M*, C* Result formats:real, imaginary,magnitude,phase, tan δ plotted vs: frequency, time, temperature, bias, ac level plotted on:Bode, complex plane Generator outputCurrent to voltage converter output (to FRA...

Open the catalog to page 3
1294bio - 4

System Requirements Solartron has been a market leader insupplying precision measurementsolutions for research andmanufacturing in the oil, gas, power,aerospace and process industries for50 years.Part of the Roxboro Group PLC,Solartron manufactures a range oflaboratory instrumentation specificallyfor electrochemistry and materials characterization which, together withour data acquisition and density andviscosity transducer products, have a global reputation for excellence inperformance, reliability and support.Solartrons Quality System is approvedto BS EN 9001: Frequency response...

Open the catalog to page 4

All Solartron Analytical catalogs and technical brochures

  1. SolarLab

    8 Pages

  2. EchemLab

    8 Pages

  3. EnergyLab

    8 Pages

  4. MODEL 1296A

    2 Pages

  5. MODEL 1260A

    2 Pages

  6. MODEL 1280C

    2 Pages

  7. MODEL 1287A

    2 Pages

  8. 1470E

    8 Pages

  9. ModuLab-MTS

    7 Pages

Archived catalogs

  1. MODEL 1294A

    4 Pages

  2. 1254A

    2 Pages

  3. zplotcorr

    2 Pages

  4. 129610A

    2 Pages

  5. 12962

    2 Pages

  6. 1296

    2 Pages

  7. 1294

    4 Pages

  8. 1287

    2 Pages

  9. 1285

    4 Pages

  10. 1281

    2 Pages

  11. 1260

    2 Pages

  12. 1255b

    2 Pages

  13. 1255a

    2 Pages

  14. 1252a

    2 Pages

  15. 1250

    2 Pages

  16. materials

    4 Pages

  17. ModuLabSystem

    12 Pages