1287
2Pages

{{requestButtons}}

Catalog excerpts

1287 - 1

logo+txt tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:9.00pt "Arial", sans-serif; } .font2 { font:13.00pt "Arial", sans-serif; } .font3 { font:20.00pt "Arial", sans-serif; } .font4 { font:25.00pt "Arial", sans-serif; } .font5 { font:30.00pt "Arial", sans-serif; } Stretching the limits of electrochemical testing solortron onolyticol 1287 Electrochemical interface The Solartron Analytical 1287 Electrochemical interface is a high accuracy, wide bandwidth potentiostat/galvanostat which offers a full range of ac/dc test capabilities; when coupled with a frequency response analyzer. Measurement Integrity Central to the measurement capability of 1287 are two high resolution digital voltmeters which provide simultaneous voltage and current measurements. Using Solartron Analytical's patented pulse width conversion technique, they have high accuracy, stability and linearity throughout the entire range of the instrument. The 1287 has excellent measurement resolution and accuracy down to 1piV for the reference electrodes and 1pA for the working electrode, which makes it an ideal choice for electrochemical noise applications or measurements where signal levels are extremely low. The 1287 uses floating measurements on all connections: it is equally at home measuring corrosion rates on grounded oil pipelines as it is in the laboratory. For safety reasons, it is often necessary to ground laboratory equipment such as autoclaves, a major problem if your instrumentation is not capable of floating measurements. The 1287 offers complete flexibility for cell connection: 2-, 3- or 4-terminal measurements can be made with equal ease. 2-terminal techniques for general materials/electrochemical testing Օ 3-terminal techniques for corrosion/coating applications 4-terminal techniques for accurate characterization of batteries/fuelcells, enabling lead resistance and impedance effects to be minimised Impedance Electrochemical Impedance Spectroscopy (EIS) is widely used to enhance the information about reaction mechanisms available from dc techniques. Designed with impedance testing very much in mind, the 1287's performance is unsurpassed; no other electrochemical interface matches the flatness and linearity of its frequency response. Solartron Analytical FRAs use a single sine correlation algorithm which offers excellent noise and harmonic rejection. The technique is particularly powerful for electrochemical applications since signal levels are usually very low (of the order of millivolts), and are inevitably buried in noise. With the 1287/1260 combination it is possible to characterize cells with a very wide range of impedances. When making high frequency impedance measurements, Solartron Analytical's driven shield technology minimizes the unwanted effects of cable impedance enabling 1287 to be used over a full 10|iHz to 1MHz frequency range. 1287 was designed to carry out both dc tests and ac impedance tests: an externally generated waveform from a frequency response analyzer or spectrum analyzer can be added to the polarization signal. Electrochemistry Software CorrWare and ZPlot packages are specifically designed to run a wide range of electrochemical tests including: Օ Impedance Potentiostatic/galvanostatic techniques Օ Cyclic voltammetry Electrochemical noise etc. CorrWare and ZPlot are an ideal tool for corrosion analysis, battery/fuel cell research, and general electrochemistry. The software provides, real-time analysis, multiple display formats and curve fitting routines.

Open the catalog to page 1
1287 - 2

logo+txt tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:6.00pt "Arial", sans-serif; } .font3 { font:16.00pt "Arial", sans-serif; } .font4 { font:18.00pt "Arial", sans-serif; } .font5 { font:20.00pt "Arial", sans-serif; } .font6 { font:4.00pt "Microsoft Sans Serif", sans-serif; } 1287 Electrochemical Interface Spcification Measurement Configuration Impedance Measurement Limits of error (for a unity gain cell Zc=Rs, measured with LO grounded) and no error due to reference electrode...

Open the catalog to page 2

All Solartron Analytical catalogs and technical brochures

  1. SolarLab

    8 Pages

  2. EchemLab

    8 Pages

  3. EnergyLab

    8 Pages

  4. MODEL 1296A

    2 Pages

  5. MODEL 1260A

    2 Pages

  6. MODEL 1280C

    2 Pages

  7. MODEL 1287A

    2 Pages

  8. 1470E

    8 Pages

  9. ModuLab-MTS

    7 Pages

Archived catalogs

  1. MODEL 1294A

    4 Pages

  2. 1254A

    2 Pages

  3. zplotcorr

    2 Pages

  4. 129610A

    2 Pages

  5. 12962

    2 Pages

  6. 1296

    2 Pages

  7. 1294bio

    4 Pages

  8. 1294

    4 Pages

  9. 1285

    4 Pages

  10. 1281

    2 Pages

  11. 1260

    2 Pages

  12. 1255b

    2 Pages

  13. 1255a

    2 Pages

  14. 1252a

    2 Pages

  15. 1250

    2 Pages

  16. materials

    4 Pages

  17. ModuLabSystem

    12 Pages