1260
2Pages

{{requestButtons}}

Catalog excerpts

1260 - 1

logo+txt tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:9.00pt "Arial", sans-serif; } .font2 { font:13.00pt "Arial", sans-serif; } .font3 { font:20.00pt "Arial", sans-serif; } .font4 { font:25.00pt "Arial", sans-serif; } .font5 { font:30.00pt "Arial", sans-serif; } Stretching the limits of impdance testing solortron onolyticol 1260 Impedance/gain-phase Analyzer The 1260 Impedance/gain-phase Analyzer is - without doubt - the most powerful, accurate and flexible Frequency Response Analyzer available today. In daily use by leading researchers wherever measurement integrity and experimental reliability are of paramount importance, 1260's solid reputation is frequently endorsed in published research papers in fields such as:- Corrosion studies 镕 Battery research and fuel cells Solar cells Օ LCDs Bio-materials Օ Ceramics / composites Electronic component development Օ Civil engineering Part of Solartron Analytical's extensive range of precision products designed to provide cost effective solutions for dc and ac analysis in electrochemical and materials research, 1260 offers an outstanding measurement specification for impedance spectroscopy: Huge frequency range Spanning 10uHz to 32MHz with 0.015ppm resolution, 1260 provides excellent coverage for virtually all chemical and molecular mechanisms -all in a single instrument. Unbeatable accuracy With an accuracy of 0.1%, 0.1°, measurements can be made with complete confidence, and even the most subtle changes in sample behavior detected and quantized. Noise free analysis 1260 uses Solartron Analytical's patented single-sine correlation technique, which inherently removes the noise and harmonic distortion which plagues lesser instruments. Frequency resolution: 1 in 65 million (0.015ppm) Օ 0.1%, 0.1° accuracy - unsurpassed by any similar instrument Resolution to 0.001dB, 0.01° -capturing every detail Օ Measures impedances >100M2 Õ 2-, 3- and 4-terminal measurement configurations Polarization voltage up to ±40.95V Օ Renowned ZPlot software package simplifies experiments and optimises throughput Systems When combined with other products from Solartron Analytical's range, including well-proven application software, 1260 can form the heart of an advanced electrochemical and materials measurement system, to provide superb accuracy, flexibility and reliability - even for the most complex research problems. Impedance measurement Virtually every liquid and solid is able to pass current when a voltage is applied to it. If a variable (ac) voltage is applied to the material, the ratio of voltage to current is known as the impedance. The measured impedance varies with the frequency of the applied voltage in a way that is related to the properties of the liquid or solid. This may be due to the physical structure of the material, to chemical processes within it or a combination of both. The advantages of impedance measurement over other techniques include:- Rapid aquisition of data Օ Accurate, repeatable measurements Non-destructive Օ Highly adaptable to a wide variety of different applications. Ability to differentiate effects due to electrodes, diffusion, mass/charge transfer by analysis over different frequency ranges Օ Equivalent circuit/modelling techniques for detailed analysis of results

Open the catalog to page 1
1260 - 2

1260 Impedance/gain-phase Analyzer SpecificationGeneratorVoltage modeCurrent mode Impedance Measurements Ω or 20mA forimpedances <50 Applies for stimulation level of 1V for impedances >50 Ω ac Amplitude ≤ 10MHz0 to 3V rms0 to 60mA rms>10MHz0 to 1V rms0 to 20mA rmsMaximum ac resolution5mV100Adc bias rangeձ40.95V100mAMaximum dc resolution10mV200ѵAOutput impedance50 > 100M 1kH1mH1 1H 10M1M100k10k1k100101100m10m Ω 1%>200k ѢĦ at <1kHzFrequencyrange: 10Hz to 32MHz, max resolution: 10յHzerror: 100ppm, stability, 24hrs ѱ1C: ڱ10ppmSweep typesfrequency (log or lin), ac/dc voltage, ac/dc...

Open the catalog to page 2

All Solartron Analytical catalogs and technical brochures

  1. SolarLab

    8 Pages

  2. EchemLab

    8 Pages

  3. EnergyLab

    8 Pages

  4. MODEL 1296A

    2 Pages

  5. MODEL 1260A

    2 Pages

  6. MODEL 1280C

    2 Pages

  7. MODEL 1287A

    2 Pages

  8. 1470E

    8 Pages

  9. ModuLab-MTS

    7 Pages

Archived catalogs

  1. MODEL 1294A

    4 Pages

  2. 1254A

    2 Pages

  3. zplotcorr

    2 Pages

  4. 129610A

    2 Pages

  5. 12962

    2 Pages

  6. 1296

    2 Pages

  7. 1294bio

    4 Pages

  8. 1294

    4 Pages

  9. 1287

    2 Pages

  10. 1285

    4 Pages

  11. 1281

    2 Pages

  12. 1255b

    2 Pages

  13. 1255a

    2 Pages

  14. 1252a

    2 Pages

  15. 1250

    2 Pages

  16. materials

    4 Pages

  17. ModuLabSystem

    12 Pages