Approvable, class III, up to 10.000 e Protection class IP 67 Extensive software applications Web server Database module DHCP client
Open the catalog to page 1Features The 3035plus Terminal with calibration capability is the ideal solution for communication applications in incoming and outgoing goods, as well as in the production, warehouse and shipping areas. Other areas of application include the food, pharmaceutical and chemical industries, as well as the electrical, construction and metal industries. Features Approvable, class III, up to 10.000 e Protection class IP 67 10 software applications Weighing and taring, totaling and order picking, counting, checking, classifying, recipe weighing, neutral measuring, vehicle weighing, dynamic switching,...
Open the catalog to page 2Products Order number Variation Approvable Model RS 232 interface incl. Ethernet interface 10 m patch cable and data/alibi memory USB interface incl. Ethernet interface 10 m patch cable and data/alibi memory RS 232 interface incl. Ethernet interface 10 m patch cable and data/alibi memory, control cabinet installation RS 232 interface incl. Ethernet interface 10 m patch cable and data/alibi memory, EX zone 2/22 USB interface incl. Ethernet interface 10 m patch cable and data/alibi memory, EX zone 2/22
Open the catalog to page 3Accessories Order number Variation Shortening of table stand to H = 200 mm (in connection with table stand) EtherCAT interface mounted WLAN module configured incl. internal antenna, installed WLAN module configured incl. internal antenna, as installation kit Bluetooth® interface incl. internal antenna installed Bluetooth® interface incl. internal antenna as installation kit Data cable for scanner / Precisa / printer 2795.20, cable length: 2 m Control/database module (over RS 232, before ordering - clarification of the application Wall / stand bracket 30xx, stainless steel (required for table...
Open the catalog to page 4Accessories Order number Variation Alibi memory Micro-SD 4GB, as installation kit (also for fixed value memory and software update) Alibi memory Micro-SD 4GB, installed (also for fixed value memory and software update) Plug-in connection with ID chip installed, approvable section point between scales and display, e.g. for in-ground installation Plug-in connection with ID chip installed, approvable section point between scale and display, e.g. for in-ground installation Plug-in connection with ID chip, straight plug D=20 mm installed, approvable section point between scale and display Data cable,...
Open the catalog to page 5Accessories Order number Variation I/O module relay, as installation kit with socket and cable fitting I/O module relay, installed with socket I/O module PNP, installed with socket I/O module PNP, installed with cable fitting CD PC service software for print format design, dataset, printer installation PC software Scale Connecting, software for transferring scale data to PC-based software Scale Connecting Plus, extensive software for transferring scale data to PC-based software (with activation code) Software for linking scale to SAP R/3, to link scale via RS232, USB or Ethernet USB adapter cable...
Open the catalog to page 6Accessories Order number Variation USB printer cable with 4 pin plug, cable length: 1.8 m Portable scanner, wire connection, incl. bench stand bracket and power supply Wireless portable scanner Bluetooth, incl. rechargeable battery, base station, RS 232 cable and power supply Print format design, customer-specific Dataset format, customer-specific Dataset/print format installation of existing or provided data UK power supply installed US power supply installed CH power supply installed Name plate, blank Name plate, with entries Ethernet interface installed, incl. 10 m patch cable Ethernet interface...
Open the catalog to page 7Accessories Order number Variation Profinet (2 ports), installed incl. module Data cable for Vibra to 3035 Data cable for Satorius to 3035, circular connector Data cable for Satorius to 3035, 25 pol. Data cable for Radwag to 3035 Measuring point installed Measuring point installed (Measuring point for filter type 3) Measuring point as installation kit Measuring point as installation kit (Measuring point for filter type 3) I/O module relay installed with cable fitting I/O module PNP, as installation kit with socket and cable fitting CD PC application software for transferring fixed values Control...
Open the catalog to page 8Accessories Order number Variation Label printer with cutter, printing width up to 104 mm (thermo direct), RS 232 Relay box (I/O module required) 2 outputs / 4 inputs Relay box (I/O module required) with power supply, 6 outputs / 4 inputs Data cable for scanner / Precisa / printer 2795.20, cable length 2m Protective cover
Open the catalog to page 910 Pages
6 Pages
8 Pages
4 Pages
6 Pages
7 Pages
10 Pages
8 Pages
5 Pages
5 Pages
10 Pages
12 Pages
8 Pages
3 Pages
5 Pages
9 Pages
6 Pages
5 Pages
2 Pages
2 Pages
3 Pages
4 Pages
4 Pages
4 Pages
6 Pages
6 Pages
4 Pages
3 Pages
4 Pages
9 Pages
7 Pages
8 Pages
6 Pages
12 Pages
12 Pages
12 Pages
12 Pages
3 Pages
3 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
9 Pages
8 Pages
6 Pages
6 Pages
4 Pages
8 Pages
4 Pages
8 Pages
6 Pages
3 Pages
4 Pages
4 Pages
10 Pages
10 Pages
6 Pages
3 Pages
3 Pages
3 Pages
3 Pages
5 Pages
32 Pages
160 Pages