video corpo cad

VENTILATION SYSTEMS WITH MOTORISED DAMPERS
48Pages

{{requestButtons}}

Catalog excerpts

VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 1

VENTILATION SYSTEMS WITH MOTORISED DAMPERS

Open the catalog to page 1
VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 2

THINGS HAVE CHANGED AND SO HAVE VENTILATION SYSTEMS.

Open the catalog to page 2
VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 3

WALL SYSTEM <- HATCH SOLUTIONS-► ROOF SYSTEM VENTILATION SYSTEMS WITH MOTORISED DAMPERS

Open the catalog to page 3
VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 4

An efficient solution to prevent heat loss in buildings. Air extract solutions in buildings or for extracting smoke in the case of fire in accordance with current regulations. They consist of automated systems that use motorised hatches with a design that is completely sealed, using cutting edge technology and with a F-400°C/2h or F-300°C/2h work certificate, depending on the application.

Open the catalog to page 4
VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 5

WALL SYSTEM The WALL system is especially designed to exhaust air or smoke through the buildings walls in the event of fire. ROOF SYSTEM The ROOF system is designed for easy installation on the roofs of buildings or industrial facilities and permits air or smoke exhaust through the roof in the event of a fire. The exhaust of both systems is carried out using a fully water-tight motorised hatch. The entire equipment is thermally insulated using technologically advanced materials. This way, heat loss from the building is prevented when the system is not operating.

Open the catalog to page 5
VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 6

HEAT LOSS AND THERMAL INSULATION One of the main disadvantages of current fans is the constant loss of heat, which results in unnecessary costs due to the use of air conditioning or heating systems. In the new HATCH systems, this disadvantage is corrected since the assembly is completely sealed and insulated using special materials designed for this purpose. This way, heat loss from the building is prevented.

Open the catalog to page 6
VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 7

THERMAL TRANSMITTANCE HATCH The lid of these HATCH extract systems is layered to a thickness of 100mm and the sides to 60mm. Heat transmission by both conduction and convection have been considered in the thermal calculations. Galvanised steel plates Thermal insulation The thermal transmittance value of HATCH systems is: U= 0.47 W/m2 ·K

Open the catalog to page 7
VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 9

WALL The hatch of these units is comprised of 80-mm thick extruded aluminium profiles with a thermal bridge break and a sandwich type central panel with high thermal insulation properties. The thermal transmittance value of the WALL systems WALL FLAP 40 - 45 0,9 W/m2 •K WALL FLAP 50 - 56 T\ Aluminium sandwich panel with high-density expanding polyurethane foam Condensation drainage Water-tightness seals Anti-detachment fixing screws in the event of fire Thermal bridge break Gutter to prevent water from filtering inside the unit

Open the catalog to page 9
VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 10

WALL SYSTEM FOR INDUSTRIAL APPLICATIONS ON WALLS The WALL system can be used in industrial facilities as it is easy to install on walls and can be integrated into the building design. The WALL system can be used for fire protection and smoke extract in the event of a fire, using series with F-400 or F-300 certificates or using the system without a temperature certification for extracting exhaust or contaminated air. The WALL systems can also be used to supply air, if necessary. The advantage of being able to automatically close the hatch when the system is not in use brings very important...

Open the catalog to page 10
VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 13

Roof extract fans in industrial buildings are used for extracting heat and contaminants and are the most common types used for industrial building. Many roof extract fans with no aesthetic requirements result in buildings having various different appearances. These roof-mounted extract fans usually permit a high amount of heat loss when they not in use; as heat rises to the top of the building, the heat loss through the extract fans is very high. By using roof HATCH systems we prevent any heat loss and give the roofs of industrial buildings a uniform appearance. We can use systems with an...

Open the catalog to page 13
VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 14

WALL SYSTEM FOR COMMERCIAL BUILDINGS APPLICATIONS ON WALLS If a fire happens in large buildings, especially those with high ceilings, it is very important to get the smoke extract design right for the safety of the personnel in that building. WALL hatch systems facilitate this because they can be installed at any point on the external walls and are perfectly incorporated into the aesthetic appearance of the building. Using these products for this application avoids the need to install large amounts of ductwork or chimneys through the roof.

Open the catalog to page 14
VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 16

ROOF SYSTEM FOR COMMERCIAL BUILDINGS APPLICATIONS ON ROOFS The demand to ensure that buildings are as sustainable as possible means that products installed in those buildings must be energy saving and efficient. The use of roof HATCH systems that are completely water-tight and with a very efficient thermal insulation results in an almost negligible loss of heat by transmission when the extract system is not being used. The use of roof HATCH systems results in almost negligible loss of heat from buildings when the extract systems are not being used because of their highly efficient thermal...

Open the catalog to page 16
VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 18

CERTIFICATIONS All WALL and HATCH systems have been subjected to different robustness tests under strenuous, snow load and wind load conditions as well as fire resistance certification tests in accordance with standard EN-12101-3, with certification numbers 0370-CPR-2823 and 0370-CPR-1827. All these tests are conducted by accredited laboratories. Certifications in accordance with EN-12101-3 WIND LOAD SNOW LOAD OPEN TIME

Open the catalog to page 18
VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 19

MOTORISED OPENING The air outlet hatch is opened by extremely robust motorised actuators. These actuators guarantee proper operation in the most adverse conditions, even under simultaneous snow and wind overload conditions to satisfy the strictest regulations on the market. This system has been tested and certified by laboratories specialising in these types of tests.

Open the catalog to page 19
VENTILATION SYSTEMS WITH MOTORISED DAMPERS - 20

EASY INSTALLATION Can be installed on any type of roof regardless of its inclination. The fan inlet may be free, suctioning directly from the premise or it can be directly connected to an extract duct using the flange that is installed at the base of the extract fan. ARCHITECTURAL INTEGRATION OF HATCH SYSTEMS The appearance of industrial or commercial buildings and their integration in the environment is undoubtedly one of the most important concerns of designers. HATCH systems can be customised to ensure that the smoke exhaust equipment can easily be integrated into the appearance of the...

Open the catalog to page 20

All SODECA catalogs and technical brochures

  1. CJPF CJPF/ATEX

    12 Pages

  2. CAP-CO2/EC

    5 Pages

  3. HATCH/HP

    12 Pages

  4. AIR CURTAINS

    26 Pages

  5. FANS FOR OVENS

    42 Pages

  6. THT/WALL

    8 Pages

  7. THT/WALL-F

    5 Pages

  8. INDUSTRIAL FANS

    340 Pages