THT/WALL-F - 1

Dynamic wall mounted extractor fans with motorised hatch, for smoke exhaust in case of fires, 400 °C/2h and300 °C/2h Dynamic wall extractor fans with motorised opening system and protective grating for use without extract duct. Specially designed for the fast, effective exhaust of harmful smoke and gases in the event of fire. Suitable for installation in industrial buildings, stores or in any other type of building. Approved as a whole in accordance with standard EN 12101-3, with F400 and F300 certificate. Can be used for ambient ventilation. Fan: • Wall fixing flange for correct and easy installation. • Support frame in galvanized sheet steel. • With F400 certificate number 0370-CPR-2823 and F300 certificate number 0370-CPR-0973. • Variable angle impeller made of cast aluminium. • Shielded power cable with EMC protection. • Airflow direction from motor to impeller. • Protection grid against contacts according to UNE-EN ISO 12499. Extruded aluminum hatch: • An extremely robust structure that is able to withstand severe weather changes. • Designed to ensure watertightness. • Aluminum profile with thermal bridge break. • Central ceiling and structure equipped with high performance thermal insulation. • Thermal resistance of the assembly less than 0.89 W/m2-K. • Limit switches in both positions (open and closed). • Manual opening system. Motor: • Class H motors for S1 continuous operation and S2 emergency use. With ball bearings, IP55 protection and 1 or 2 speeds, depending on model. • IE3 efficiency motors. • Three-phase 230/400 V 50 Hz (up to 3 kW) and 400/690 V 50 Hz (powers greater than 3 kW). • Maximum temperature of air to be carried: S1 -25 °C +40 °C continuous service, also suitable for warm climates with temperatures up to 50 °C. S2 operation, 300 °C/2h, 400 °C/2h. Actuator: • Reliability greater than 11,000 dual cycles. • Supply voltage at 230 V AC 50/60 Hz. • Working temperature: -25 °C +60 °C. Flap finish: • Anti-corrosive in extruded aluminum. • RAL 7016 supplied as standard. Any other RAL can be supplied on demand. THT/WALL-F: Dynamic wall mounted Impeller extractor fans with motorised hatch, diameter for smoke exhaust in case of fires, in cm Number of motor poles T = Three-phase 2=3000 r/min 50 Hz 4=1500 r/min 50 Hz 6=1000 r/min 50 Hz

Open the catalog to page 1
THT/WALL-F - 2

Installed Blade tilt Maximum Sound pressure level1 Approx. power angle flow rate dB (A) weight 1 The noise level values are pressures in dB(A) measured at a distance of 10 metres in a free field. Speed (r/min) Maximum admissible current (A) Technical characteristics of the dynamic exhaust system based on standards EN-12101-3 Model Motor insulation class Temperature room temperature Wind load Erp. (Energy Related Products) Information on Directive 2009/125/EC can be downloaded from the SODECA website or the QuickFan selector programme. Acoustic characteristics Sound power spectrum Lw(A)...

Open the catalog to page 2
THT/WALL-F - 3

Acoustic characteristics Sound power spectrum Lw(A) in dB(A) per Hz frequency band Values measured at inlet with maximum flow rate Values measured at exhaust with maximum flow rate (C x D) Nominal size of the wall opening.

Open the catalog to page 3
THT/WALL-F - 4

Characteristic curves Q= Flow rate in m³/h, m³/s and cfm Pe= Static pressure in mm H₂O, Pa and inwg

Open the catalog to page 4
THT/WALL-F - 5

Characteristic curves Q= Flow rate in m3/h, m3/s and cfm Pe= Static pressure in mm H2O, Pa and inwg