SV/FILTER/EC SV/HEPA/EC - 1

SV/FILTER/EC SV/HEPA/EC HIGH EFFICIENCY AIR FILTRATION UNITS • E.C. TECHNOLOGY MOTOR WITH BUILT-IN ELECTRONICS • DIFFERENT FILTRATION STAGES DEPENDING ON THE MODEL: • FILTERS F6 + F8 AND F7 + F9 • FILTER HEPA H14 • ACTIVE CARBON FILTER • PRESSURE CONNECTIONS FOR FILTER CONTROL • IDEAL FOR OFFICES AND BUSINESSES • FILTERS WITH ANTI BY-PASS SETTING • EASY ACCESS FOR MAINTENANCE

Open the catalog to page 1
SV/FILTER/EC SV/HEPA/EC - 2

SV/FILTER/EC SV/HEPA/EC SV/FILTER/EC and SV/HEPA/EC air filtration units have been especially designed for moving and filtering air, in installations with stringent energy efficiency, filtration, soundproofing and versatility requirements. INSTALLATION IN ANY POSITION This unit is ready to be installed in any position and thanks to its low profile, it is ideal to be installed inside technical ceilings or locations with limited available space. EASY INSTALLATION AND MAINTENANCE An inspection cover with manual locks is used for quick access for cleaning the impeller and replacing the filters....

Open the catalog to page 2
SV/FILTER/EC SV/HEPA/EC - 3

ENERGY SAVINGS The high performance E.C. Technology electric motor is a key element in reducing electricity consumption, in addition to being easy to regulate with any 0-10 V sensor. FILTRATION STAGES 4 standard filtration stage configurations are available: F6 + F8, F7 + F9, F7 + H14, G4 + CA. The unit is equipped with a rail for installing a 25 mm pre-filter that will extend the service life of the high efficiency filters. CONTROL OF FILTERS The status of both filters can be individually controlled via the three pressure connections. This control prevents oversaturating each one of the...

Open the catalog to page 3
SV/FILTER/EC SV/HEPA/EC - 4

SV/FILTER/EC SV/HEPA/EC DESIGNED FOR INSTALLATIONS WITH STRINGENT ENERGY EFFICIENCY, FILTRATION, SOUNDPROOFING AND VERSATILITY REQUIREMENTS SHOPPING CENTRES FOOD PRODUCTION UNITS AND RIPENING ROOMS

Open the catalog to page 4
SV/FILTER/EC SV/HEPA/EC - 5

LARGE OFFICES, CONFERENCE ROOMS AND WAITING ROOMS ROOMS, TOILETS AND DRESSING ROOMS HEALTH CENTRES PUBLIC TRANSPORTATION

Open the catalog to page 5
SV/FILTER/EC SV/HEPA/EC - 6

SV/FILTER/ECFiltration units for circular ducts and EC Technology motor Filtration units for circular ducts, with low noise level, different filtration stage options and EC Technology motor. Fan: • Acoustic casing covered with sound absorbing material. • Standardised inlet and outlet flanges with watertight joints. • F6 + F8, F7 + F9 and G4 + CA, filters according to model. • Easy access inspection and cleaning cover with manual fasteners. • Centrifugal fan with a backward curved impeller. • Integrated support into the box which facilitates its assembly. • Linear airflow direction. • 3...

Open the catalog to page 6
SV/FILTER/EC SV/HEPA/EC - 7

Erp. (Energy Related Products) Information on Directive 2009/125/EC can be downloaded from the SODECA website or the QuickFan selector programme. Sound power spectrum Lw(A) in dB(A) per Hz frequency band Irradiated values at maximum speed and medium flow rate. 63 125 250 500 1000 2000 4000 8000

Open the catalog to page 7
SV/FILTER/EC SV/HEPA/EC - 8

Characteristic curves Q= Flow rate in m3/h, m3/s and cfm Pe= Static pressure in mm H2O, Pa and inwg inwg inwg

Open the catalog to page 8
SV/FILTER/EC SV/HEPA/EC - 9

Characteristic curves Q= Flow rate in m³/h, m³/s and cfm Pe= Static pressure in mm H₂O, Pa and inwg

Open the catalog to page 9
SV/FILTER/EC SV/HEPA/EC - 10

Characteristic curves Q= Flow rate in m3/h, m3/s and cfm Pe= Static pressure in mm H2O, Pa and inwg Inwg inwg

Open the catalog to page 10
SV/FILTER/EC SV/HEPA/EC - 11

SV/HEPA/ECHEPA filtration units for circular ducts and EC Technology motor HEPA filtration units for circular ducts, with low noise level and EC Technology motor. Fan: • Acoustic casing covered with sound absorbing material. • Standardised inlet and outlet flanges with watertight joints. • F7 + H14 filters. • Easy access inspection and cleaning cover with manual fasteners. • Centrifugal fan with a backward curved impeller. • Integrated support into the box which facilitates its assembly. • Linear airflow direction. • 3 pressure taps for individual control of the two filtration stages. •...

Open the catalog to page 11
SV/FILTER/EC SV/HEPA/EC - 12

Erp. (Energy Related Products) Information on Directive 2009/125/EC can be downloaded from the SODECA website or the QuickFan selector programme. Acoustic characteristics Sound power spectrum Lw(A) in dB(A) per Hz frequency band Irradiated values at maximum speed and medium flow rate. 63 125 250 500 1000 2000 4000 8000

Open the catalog to page 12
SV/FILTER/EC SV/HEPA/EC - 13

Characteristic curves Q= Flow rate in m3/h, m3/s and cfm Pe= Static pressure in mm H2O, Pa and inwg inwg inwg

Open the catalog to page 13
SV/FILTER/EC SV/HEPA/EC - 14

Characteristic curves Q= Flow rate in m³/h, m³/s and cfm Pe= Static pressure in mm H₂O, Pa and inwg

Open the catalog to page 14
SV/FILTER/EC SV/HEPA/EC - 15

Characteristic curves Q= Flow rate in m3/h, m3/s and cfm Pe= Static pressure in mm H2O, Pa and inwg inwg inwg

Open the catalog to page 15
SV/FILTER/EC SV/HEPA/EC - 16

HEADQUARTER Sodeca, S.L.U. Pol. Ind. La Barricona Carrer del Metall, 2 E-17500 Ripoll Girona, SPAIN Tel. +34 93 852 91 11 Fax: +34 93 852 90 42 General sales: comercial@sodeca.com Export sales: ventilation@sodeca.com PRODUCTION PLANT Sodeca, S.L.U. Ctra. de Berga, km 0,7 E-08580 Sant Quirze de Besora Barcelona, SPAIN Tel. +34 93 852 91 11 Fax: +34 93 852 90 42 General sales: comercial@sodeca.com Export sales: ventilation@sodeca.com HYVINKAA Industrial Applications Mr. Jaakko Tomperi Niinistonkatu 12 FI-05800 Hyvinkaa Tel. +358 451 651 333 jtomperi@sodeca.com EUROPE FINLAND Sodeca Finland,...

Open the catalog to page 16

All SODECA catalogs and technical brochures

  1. CJPF CJPF/ATEX

    12 Pages

  2. CAP-CO2/EC

    5 Pages

  3. HATCH/HP

    12 Pages

  4. AIR CURTAINS

    26 Pages

  5. FANS FOR OVENS

    42 Pages

  6. THT/WALL

    8 Pages

  7. THT/WALL-F

    5 Pages

  8. INDUSTRIAL FANS

    340 Pages