Product catalog summary
Introduction
SODECA specializes in industrial ventilation solutions, focusing on smoke exhaust, staircase pressurization, and indoor air quality improvement. Their systems are ISO 9001:2015 certified, ensuring high manufacturing standards.
Smoke Control Systems
SODECA's smoke control systems are crucial for safe evacuation and firefighting during fires, complying with EN 12101-3:2015 for reliable operation under fire conditions. They offer personalized project support, including technical studies and system design.
Applications and Projects
SODECA has implemented ventilation solutions in various international projects, such as car parks, shopping centers, schools, and hotels, serving both daily comfort and emergency smoke control purposes.
Quality and Standards
SODECA adheres to international standards like ISO 13500 and ISO 5801 for performance testing, ensuring rigorous inspection of manufacturing processes and materials.
Research and Development
Continuous R&D efforts focus on enhancing safety, durability, and efficiency, using advanced tools like CFD simulations and BIM systems for project management and design.
Specific Applications
  • Car Parks: Systems control smoke, gas concentrations, and explosive gases, optimizing power consumption.
  • Industrial and Public Buildings: Smoke exhaust systems protect structures and evacuation routes.
  • Cold Rooms: Mechanical extraction systems are essential due to unique environmental challenges.
  • Evacuation Routes: Pressurization systems prevent smoke entry, maintaining clear escape paths.
  • Tunnels: Ventilation systems ensure safe air quality and smoke control during emergencies.
Conclusion
SODECA's comprehensive solutions and adherence to international standards make them a leader in the ventilation sector, providing reliable systems for various applications.
Specifications
The document details specifications for extract fans and pressurization systems designed for fire safety, engineered to operate under high-temperature conditions (400°C for 2 hours and 300°C for 2 hours).
Technical Characteristics
Specifications include motor power, speed, maximum flow rate, sound pressure levels, and weight. Fans comply with IE3 efficiency standards, suitable for continuous and emergency operations.
Pressurization Systems
Advanced systems maintain differential pressure in evacuation routes, compliant with EN 12101-6, including control panels and various configurations for optimal performance during fire emergencies.
Accessories
Accessories complement extract fans and pressurization systems, enhancing functionality and safety, including control panels, safety switches, coupling flanges, silencers, and sensors.
Certifications and Standards
Products are certified according to relevant standards, such as EN 12101-3 for fire safety, ensuring reliability and compliance with safety regulations.
Key Features
Critical features include anti-corrosive finishes, variable angle impellers, and options for reversible airflow direction, designed for ease of maintenance and high efficiency.
Procedures
Selection procedures involve marking the working point on pressure and power graphs to determine the appropriate equipment curve and motor power, with examples of selection and order codes for different configurations.
Recommendations
Recommendations include selecting the correct motor power and impeller diameter based on the required flow rate and static pressure, with configurations for different installation scenarios.
Installation and Configuration
Examples of installation configurations with BOXPARK control units highlight the control of CO concentration levels and smoke extraction in case of fire, emphasizing the importance of customized control panels.
Technical Specifications
Specifications for various models of extractor fans and centrifugal fans include speed, maximum admissible current, installed power, maximum flow rate, sound pressure level, and approximate weight.
Acoustic Characteristics
Sound power spectrum data is provided for different frequency bands, crucial for understanding noise levels associated with each fan model.
Dimensions
Dimensions for each fan model are provided, essential for installation and spatial planning.
Motor and Fan Details
Motors are Class H with IP55 protection, suitable for continuous and emergency use, with single-phase and three-phase options.
Applications
Fans are designed for use in fire zones, capable of operating at high temperatures, suitable for various industrial and residential applications.
Control and Connectivity
Systems are equipped with ModBUS RTU ports for integration with Building Management Systems (BMS), with external control panels for real-time system status and manual activation options.
Installation and Maintenance
Systems are designed for easy installation and start-up, with features ensuring safe and functional operation, including time programming for daily ventilation activation.
Additional Features
Includes automatic switching systems for backup fans and reversible pressurization equipment for smoke exhaust.
Conclusion
The document provides comprehensive details on the design, specifications, and operational procedures of pressurization systems for fire safety in buildings, crucial for maintaining safe evacuation routes by preventing smoke ingress.
See more

Catalog excerpts

SOLUTIONS IN SMOKE EXHAUST-1

SOLUTIONS IN SMOKE EXHAUST EN-12101-3 POWERED SMOKE AND HEAT EXHAUST VENTILATORS FOR USE IN CONSTRUCTION WORKS

 Open the catalog to page 1
SOLUTIONS IN SMOKE EXHAUST-2

SODECA offers solutions in industrial ventilation, smoke exhaust, staircase pressurisation and improving indoor air quality.

 Open the catalog to page 2
SOLUTIONS IN SMOKE EXHAUST-3

Our quality procedures, certified in accordance with ISO 9001:2015, have placed Grupo SODECA as one of the best and most recognised fan manufacturers in the world. As a result of the expansion process and consolidation of the business, in 2018 we inaugurated the new headquarters located in Ripoll, a municipality near Barcelona. These new installations have a surface area of more than 15,000 m2, distributed into offices, customer service area, warehouse and production area. Currently, SODECA has become an international leader in the ventilation sector; primarily for its solutions in fire protection,...

 Open the catalog to page 3
SOLUTIONS IN SMOKE EXHAUST-4

SYSTEMS FOR CONTROLLING SMOKE IN THE EVENT OF FIRE "80% of fire victims are a result of the harmful effects of smoke: toxic inhalation, temperature, asphyxia and lack of visibility". Controlling smoke in the event of a fire is essential in order to evacuate people and for fire-fighters to extinguish the fire, helping to create smoke free zones or ensuring the temperature and visibility are suitable in each case. Additionally, if the smoke is controlled, material assets are protected as well as the building's enclosures and structures, allowing to resume the business activity more quickly. To...

 Open the catalog to page 4
SOLUTIONS IN SMOKE EXHAUST-5

SODECA PROJECTS SODECA has helped provide ventilation solutions for smoke extraction in international emblematic infrastructures. CAR PARK VENTILATION Hotel Sheraton Grand Tbilisi Palace, Georgia CAR PARK VENTILATION Madrid RIO shopping centre, Spain SMOKE EXHAUST Romsdal High School, Norway PRESSURISATION OF STAIRCASES Phoenicia Hotel *****, Valletta DEPRESSURISATION OF STAIRCASES Penrose Dock, Ireland SMOKE EXHAUST Silo Inditex, Madrid

 Open the catalog to page 5
SOLUTIONS IN SMOKE EXHAUST-6

MEETING INTERNATIONAL STANDARDS QUALITY MANAGEMENT SYSTEM SODECA has implemented a Quality Management System that is certified in accordance with ISO 9001:2015 by Bureau Veritas, who has certified the company's ability to plan, execute and control the processes required for carrying out their work and keeping customers satisfied by delivering products manufactured using the highest quality standards. A company committed to the reliability and warranty of their equipment installed at locations that are difficult to access and are fire safety system components. For this reason, all critical points...

 Open the catalog to page 6
SOLUTIONS IN SMOKE EXHAUST-7

FAN TESTS AND FACTORY ACCEPTANCE TEST (FAT) The performance criteria of fans are essential to ensure a proper application of the ventilation system inside the tunnel. Therefore, SODECA is strict in terms of achieving equipment performances and to achieve fan performance, the company follows a test methodology and test procedures as well as standards of renown prestige such as ISO 13350 and ISO 5801. • Motor consumption • Flow • Pressure • Thrust • Noise levels • Vibrations RAT Factory The client has the Acceptance possibility of validating T t the performance and good operation of the equipment...

 Open the catalog to page 7
SOLUTIONS IN SMOKE EXHAUST-8

QuiCKFan SODECA M SELECTOR Calculation software QuickFan is the software used for making calculations and designing ventilation projects. Selecting the most suitable product for your ventilation installation is now easier than ever. Make it easy with QuickFan! CONSULTING AND DESIGN With the aim of offering a comprehensive service, SODECA offers support in consulting, design and personalised studies. COMPUTATIONAL FLUID DYNAMICS CFD We have the most advanced computational CFD simulation tools and the necessary experience in their use. This study makes it possible to check if the system operating...

 Open the catalog to page 8
SOLUTIONS IN SMOKE EXHAUST-9

SYSTEMS FOR SMOKE CONTROL IN THE EVENT OF FIRE — CAR PARKS — INDUSTRIAL BUILDINGS AND PUBLICLY USED BUILDINGS — COLD ROOMS — EVACUATION ROUTES — TUNNELS

 Open the catalog to page 9
SOLUTIONS IN SMOKE EXHAUST-10

CAR PARKS It is essential for the ventilation system for car parks to be reliable throughout the years to ensure it is safe for users. In car parks, ventilation may be natural or forced. In the latter, fans must be installed to properly move the air and maintain the required conditions of safety and comfort under normal conditions as well as in the event of a fire. Car park ventilation systems are installed to carry out three functions: 5) Control smoke in the event of a fire, to help occupants evacuate as well as help fire-fighters extinguish the fire. Maintain the concentration of contaminating...

 Open the catalog to page 10
SOLUTIONS IN SMOKE EXHAUST-11

VENTILATION SYSTEMS IN CAR PARKS MECHANICAL VENTILATION THROUGH DUCT SYSTEMS MECHANICAL VENTILATION ASSISTED BY IMPULSE VENTILATION NATURAL VENTILATION ASSISTED BY IMPULSE VENTILATION IMMERSED Installation of fan for immersed operation in fire risk zone EXTERNAL Installation of outdoor fans in the fire risk zone JET FAN Installation of jet fan in the fire risk zone

 Open the catalog to page 11
SOLUTIONS IN SMOKE EXHAUST-12

INDUSTRIAL BUILDINGS AND PUBLICLY USED BUILDINGS Smoke exhaust solutions limit the effects of heat and evacuate the smoke that is generated in the event of a fire. These ventilation systems can extract hot gases generated at the start of a fire and create smoke free areas below the layers of floating smoke, helping the evacuation as well as the fire-fighting effort. Also, the appearance of secondary fires is prevented as well as control the temperature of the smoke to prevent the building from collapsing. Protect the evacuation routes Control of the temperature of gases The use of smoke exhaust...

 Open the catalog to page 12
SOLUTIONS IN SMOKE EXHAUST-13

VENTILATION SYSTEMS IN INDUSTRIAL BUILDINGS AND PUBLICLY USED BUILDINGS SMOKE EXHAUST IN BUILDINGS WITH A SINGLE FLOOR SMOKE EXHAUST IN MULTI-LEVEL BUILDINGS

 Open the catalog to page 13
SOLUTIONS IN SMOKE EXHAUST-14

COLD ROOMS The implementation of a smoke control system in the event of a fire in cold rooms have unique differences compared to traditionally installed smoke control systems in industrial buildings; specifically: The equipment installed on the casing of the cold room requires thermal insulation features in order to prevent high energy losses. DROPBOX EDNA The presence of a dual ceiling (ceiling of the room and building roof ) makes it difficult to exhaust the smoke produced during a fire to the exterior from inside the cold room. The presence of low temperatures inside the cold room may reduce...

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.