MOTORISED DAMPERS FOR SMOKE CONTROL IN CASE OF FIRE
8Pages

{{requestButtons}}

Catalog excerpts

MOTORISED DAMPERS FOR SMOKE CONTROL IN CASE OF FIRE - 1

• DAMPER OPERATED BY • 600 °C FIRE TEST ELECTRIC ACTUATOR • CE MARKING • HIGH AIR TIGHTNESS • MINIMAL PRESSURE DROP MOTORISED SMOKE CONTROL DAMPERS

Open the catalog to page 1
MOTORISED DAMPERS FOR SMOKE CONTROL IN CASE OF FIRE - 2

KEEP ESCAPE ROUTES SMOKE FREE In the event of a fire, smoke and high-temperature gases are the greatest threat to people inside the building. Smoke reduces visibility and contains toxic components that reduce the evacuation possibilities of people, as well as making extinguishing tasks more difficult. The installation of an adequate smoke extraction system ensures the safe evacuation of people in case of fire and reduces the chances of serious smoke contamination. Fire safety features must ensure good performance and resistance to fire and high temperatures and prevent smoke leakage away...

Open the catalog to page 2
MOTORISED DAMPERS FOR SMOKE CONTROL IN CASE OF FIRE - 3

Smoke exhaust system Pressurisation system for stairs, halls and evacuation routes, complemented by smoke exhaust system <#> Smoke exhaust fans H Closed smoke damper ^ Opened smoke damper 0 Closed air inlet damper 0 Opened air inlet damper Duct with grill

Open the catalog to page 3
MOTORISED DAMPERS FOR SMOKE CONTROL IN CASE OF FIRE - 4

Multi-compartment dampers allow the smoke and fire to be confined to the sector where the ignition has occurred, preventing it from spreading to other sectors. In the event of a fire, the smoke extraction dampers of the affected sector are opened to evacuate the smoke. At the same time, the air supply dampers in the fire area are activated together with the smoke extraction fan. The rest of the dampers in the building remain closed to prevent the fire and smoke from spreading to unaffected areas. CONTROL The dampers are controlled from the central fire detection control system and can be...

Open the catalog to page 4
MOTORISED DAMPERS FOR SMOKE CONTROL IN CASE OF FIRE - 5

SMOKE EXTRACTION DAMPERS SINGLE COMPARTMENT Single compartment smoke exhaust dampers are designed for smoke exhaust from buildings with a single fire section. In an emergency, the smoke exhaust system opens the damper in the affected section and exhausts the smoke and heat from this section. Single compartment smoke control dampers are classified as follows: E600 120 (ve - i o) S1500CmodMAsingle SCDLS-MA Single compartment smoke control dampers with manual and automatic operation SCDRS-MA Single compartment circular smoke control dampers with manual or automatic operation Features: •...

Open the catalog to page 5
MOTORISED DAMPERS FOR SMOKE CONTROL IN CASE OF FIRE - 6

SODECA offers a wide range of solutions for fire safety and together with the smoke control dampers maximise safety in case of fire. THT THT/CL THT/WALL THT/WALL-F 400°C/2h and 300°C/2h tubular axial extract fans with short casings 400 °C/2h and 300 °C/2h tubular axial extractor fans with long casing and external terminal boxes Dynamic wall mounted extractor fans with motorised hatch, for smoke exhaust in case of fires, 400 °C/2h and 300 °C/2h Dynamic wall mounted extractor fans with motorised hatch, for smoke exhaust in case of fires, 400 °C/2h and 300 °C/2h THT/HATCH 400°C/2h and 300°C/2h...

Open the catalog to page 6
MOTORISED DAMPERS FOR SMOKE CONTROL IN CASE OF FIRE - 7

KIT SOBREPRESION Pressurisation system for stairs or evacuation routes. Maintains a differential pressure of 50 Pa in a single stage, designed according to the European standard EN 12101-6 KIT BOXPRES PLUS Pressurisation system for stairs or evacuation routes. Maintains a differential pressure of 50 Pa in a single stage, designed according to the European standard EN 12101-6 PRESSKIT Pressurisation equipment for lobbies, compliant with DM 30/11/1983 and designed according to the European standard EN 12101-6 BOXPRES PLUS Control panel for a fan Control panel with standby fan Pressurisation...

Open the catalog to page 7
MOTORISED DAMPERS FOR SMOKE CONTROL IN CASE OF FIRE - 8

HEADQUARTER Sodeca, S.L.U. Pol. Ind. La Barricona Carrer del Metall, 2 E-17500 Ripoll Girona, SPAIN Tel. +34 93 852 91 11 Fax: +34 93 852 90 42 General sales: comercial@sodeca.com Export sales: ventilation@sodeca.com PRODUCTION PLANT Sodeca, S.L.U. Ctra. de Berga, km 0,7 E-08580 Sant Quirze de Besora Barcelona, SPAIN Tel. +34 93 852 91 11 Fax: +34 93 852 90 42 General sales: comercial@sodeca.com Export sales: ventilation@sodeca.com EUROPE FINLAND Sodeca Finland, Oy HUITTINEN Sales and Warehouse Mr. Kai Yli-Sipila Metsalinnankatu 26 FI-32700 Huittinen Tel. + 358 400 320 125...

Open the catalog to page 8

All SODECA catalogs and technical brochures

  1. CJPF CJPF/ATEX

    12 Pages

  2. CAP-CO2/EC

    5 Pages

  3. HATCH/HP

    12 Pages

  4. AIR CURTAINS

    26 Pages

  5. FANS FOR OVENS

    42 Pages

  6. THT/WALL

    8 Pages

  7. THT/WALL-F

    5 Pages

  8. INDUSTRIAL FANS

    340 Pages