video corpo cad

AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS
172Pages

{{requestButtons}}

Catalog excerpts

AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS - 1

ROOF-MOUNTED EXTRACT FANS

Open the catalog to page 1
AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS - 2

SODECA has focused its business activity on the manufacture of industrial fans, ventilation systems and smoke exhaust fans for fire protection since it was set up in 1983. The fans and extract fans manufactured by Sodeca are present in Europe and in many other parts of the world due to their quality and the research and development methods used. Our quality procedures, certified by BUREAU VERITAS in accordance with ISO 9001:2015, are another reason why SODECA is positioned as one of the best and most recognised fan manufacturer in Europe. There is no doubt that the most important element in...

Open the catalog to page 2
AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS - 3

AXIAL FANS Since it was first established, Sodeca has specialised in the design and manufacture of fans and their accessories for industrial applications. at manufacturing and supplying special industrial fans with extremely tight deadlines in terms of their design and production. The combination of its experience gained over decades of working with fans and the technology provided by the engineers employed in its different departments has allowed Sodeca to occupy a leading international position as a fan manufacturer. The teamwork of our engineering department, in conjunction with...

Open the catalog to page 3
AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS - 4

EXTRACT SYSTEMS WITH ROOF-MOUNTED EXTRACT FANS SAFETY IN THE EVENT OF FIRE The fire protection standards make it obligatory to apply temperature control and smoke extraction systems in accordance with standard UNE / EN-23585, calculation and design requirements and methods for planning a temperature control and smoke extraction system in the event of fire. To provide a solution to the needs established by this standard, approved roof-mounted fans exist for this purpose, pursuant to standard EN-12101-3 with an F-400 (400ºC/2h) or F-300 (300ºC/2h) certificate. COMFORT AND NOISE REDUCTION A...

Open the catalog to page 4
AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS - 5

SODECA fans and extract fans comply with the following standards: ISO 9001:2015 Sistemas de gestion de la calidad. Requisitos. Quality management systems -- Requirements. ATEX EXECUTIONS Directive ATEX 2014/34/EU

Open the catalog to page 5
AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS - 6

AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS AXIAL FANS Wall-mounted axial fans with IP65 motors. Circular axial fans with external rotor motors. Long range, one-way or reversible jet fans. Large diameter tubular axial fans with direct drive motors. Forked tubular axial fans with motors outside the air flow. Wall-mounted axial fans with IP65 motors. Wall-mounted axial fans with low-noise sheet steel impellers. Long-range, circular, one-way or reversible jet fans. Large diameter tubular axial fans with direct drive motors. Fans designed to work in kilns, drying barns and other applications with...

Open the catalog to page 6
AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS - 7

ROOF-MOUNTED FANS Roof-mounted axial extract fans with flat bases. Roof-mounted multifunctional extract fans for large flow rates. 400ºC/2h and 300ºC/2h roof-mounted multifunctional extract fans. Roof-mounted axial extract fans with vertical air outlets. 400ºC/2h and 300ºC/2h roof-mounted axial extract fans with vertical air outlets. Centrifugal roof-mounted extract fans fitted with E.C. Technology external rotor motor and constant pressure control. Roof-mounted axial extract fans with inclined supports, depending on the roof inclination. 400ºC/2h centrifugal roof-mounted extract fans, with...

Open the catalog to page 7
AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS - 8

AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS HEP HEPT HEP: Wall-mounted axial fans with IP65 motors HEPT: Tubular axial fans with IP65 motors HEP Wall-mounted axial (HEP) and tubular (HEPT) fans with reinforced plastic impeller made of fibreglass. Fan: • Airflow direction from motor to impeller. • Fibreglass-reinforced polyamide-6 impeller. • HEP: Sheet steel support frame. • HEP: Anti-contact protective grille pursuant to standard UNE-EN ISO 12499. • HEPT: Sheet steel tubular casing. • HEPT: External junction box, IP65 protection. Motor: • Class F motors with ball bearings and IP65 protection....

Open the catalog to page 8
AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS - 9

Technical characteristics Speed Maximum admissible Power Maximum Noise Approx. According current (A) absorb. free flow rate level weight (kg) to ErP (r/min) 220-240V 380-415V discharge (W) (m3/h) dB(A) HEP HEPT Erp. (Energy Related Products) Information on Directive 2009/125/EC can be downloaded from the SODECA website or the QuickFan selector programme. Acoustic characteristics The indicated values are determined by measuring the pressure and sound power levels in dB(A) obtained in a free field at a distance equivalent to twice the size of the fan plus the impeller diameter, with a minimum...

Open the catalog to page 9
AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS - 10

Number Model 0A 0B 0D F E 0J of holes Characteristic curves Q= Flow rate in m3/h, m3/s and cfm. Pe= Static pressure in mm H2O, Pa and inwg.

Open the catalog to page 10
AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS - 11

Characteristic curvesQ= Flow rate in m3/h, m3/s and cfm. Pe= Static pressure in mm H2O, Pa and inwg.HEP/HEPT-45 I-'-1-1-1-1-1-'-1-1-1-•" HEP/HEPT-56 HEP/HEPT-63 o AccessoriesSee accessories section. RM VSD3/A-RFT ELECTRIC PL VSD1/A-RFM CONTROL PANELS

Open the catalog to page 11
AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS - 12

AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS HCWall-mounted axial fans with IP55 motors Wall-mounted axial fans with reinforced plastic impeller made of fibreglass. Fan: • Sheet steel support frame. • Fibreglass-reinforced polyamide-6 impeller. • Anti-contact protective grille pursuant to standard UNE-EN ISO 12499. • Models 71,80, 90 and 100, protective grille supplied as an accessory • Airflow direction from motor to impeller. Motor: • IE3 efficiency motors for powers equal to or higher than 0.75kW except singlephase, 2-speed and 8-pole. • Class F motors with ball bearings, IP55 protection,...

Open the catalog to page 12
AXIAL FANS AND ROOF-MOUNTED EXTRACT FANS - 13

Model Speed (r/min) Maximum admissible current (A) 230V 400V 690V Maximum Sound flow rate pressure level (m3/h) dB(A) /f?\ Approx. According weight to ErP (kg) * Equipment not covered by Directive 2009/125/EC Erp. (Energy Related Products) Information on Directive 2009/125/EC can be downloaded from the SODECA website or the QuickFan selector programme. Acoustic characteristics The indicated values are determined by measuring the pressure and sound power levels in dB(A) obtained in a free field at a distance equivalent to twice the size of the fan plus the impeller diameter, with a minimum...

Open the catalog to page 13

All SODECA catalogs and technical brochures

  1. CJPF CJPF/ATEX

    12 Pages

  2. CAP-CO2/EC

    5 Pages

  3. HATCH/HP

    12 Pages

  4. AIR CURTAINS

    26 Pages

  5. FANS FOR OVENS

    42 Pages

  6. THT/WALL

    8 Pages

  7. THT/WALL-F

    5 Pages

  8. INDUSTRIAL FANS

    340 Pages