1. Catalogs
  2. SOCOMEC
  3. SURGYS® E10

SURGYS® E10

SURGYS® E10

SURGYS® E10

Product catalog summary
Overview
SURGYS® E10 surge arresters are designed to protect installations connected to single-phase, three-phase, or DC networks from industrial operation surges and transient surges due to lightning. They are suitable for use in various sectors including industry, infrastructure, and all types of buildings.

Key Features
  • Monobloc Design: Ensures easy installation.
  • Plug-in Module: Facilitates quick maintenance on end-of-life modules.
  • Remote Signalling: Allows alerts to be uploaded to a supervisory device.

Applications
  • AC or DC distribution boards downstream of a main switchboard.
  • Protection of electrotechnical equipment such as motors, switching devices, and control devices.

Compliance
  • NF EN 61643-11
  • IEC 61643-11

Specifications
  • Monobloc design with end-of-life signal and remote signalling contact.
  • DIN rail mounted with plug-in module.
  • Available in AC and DC versions with common mode (MC) and differential mode (MC/MD) protection.

Protection Characteristics
  • Nominal voltage: 400 VAC / 230 VAC
  • Max. voltage: 440 VAC / 255 VAC
  • Temporary overvoltage withstand: 580 VAC / 335 VAC for 5 seconds, 770 VAC / 440 VAC for 120 seconds.
  • Level of protection: 1.3 kV / 1.5 kV / 0.9 kV
  • Max. current discharge: 10 kA
  • Nominal discharge current: 5 kA

Associated Characteristics
  • Residual current: < 1 mA
  • Response time: < 5 ns
  • Admissible short-circuit current: 25 kA
  • Recommended disconnector: gG 20 A fuses

Operating Conditions
  • Operating temperature range: -40 to +85°C
  • Storage temperature range: -40 to +85°C

Physical Characteristics
  • Case material: Thermoplastic UL94-V0
  • Case degree of protection: IP20
  • Dimensions vary based on the number of poles (2, 3, or 4).

References
  • Various references for different configurations and spare modules for both AC and DC applications.
See more

Catalog excerpts

SURGYS® E10-1

SURGYS® E10 Surge arrester - Types 2 and 3 for terminal receivers and sensitive loads The solution for Electronic protection > Industry > Infrastructure > All types of building (critical, non-critical) > OEM Strong points > Monobloc design > Plug-in module > Remote signalling SURGYS E10 - 2 pole MC/MD Function SURGYS® E10 surge arresters are designed to ensure protection of installations connected to single-phase, three phase or DC networks against industrial operation surges. They act against transient surges owing to lightning. Advantages Monobloc design Easy to install. Plug-in module Quick maintenance on end-of-life modules. Remote signalling With the remote signalling contact (plug-in) you can upload the alert to a supervisory device. Applications • AC or DC distribution board (downstream of a main switchboard). • Protection of electrotechnical equipment such as motors, switching devices, control devices... SURGYS G70 Compliance with standards > NF EN 61643-11 > IEC 61643

 Open the catalog to page 1
SURGYS® E10-2

Surge arrester - Types 2 and 3 for terminal receivers and sensitive loads Front panel Specifications Mains 1. Monobloc design. 2. End of life signal. 3. Remote signalling contact. 4. DIN rail mounted. 5. Plug-in module. Mains type Neutral arrangement (see table) Temporary overvoltage withstand @ 120 sec (UT) Temporary overvoltage withstand @ 5 sec (UT) Connection mode Protection characteristics Temporary overvoltage from a HV mains, between N & PE in a TT arrangement Nominal discharge current (15 impulses 8/20 µs) In Max. current discharge (1 impulse 8/20 µs) Imax AC version - Common mode (MC)...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.