CATALOGUE EXTRACT INOSYS LBS Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications

Open the catalog to page 1
Catalogue extract : INOSYS LBS Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications - 2

INOSYS LBS Load Break Switches incorporating tripping function Emergency switching Main switchboards Distribution panels Motor load breaks Strong points a.psd Load break switches INOSYS LBS 3-poles with tripping function > High-performance switching in a compact footprint > Safe operation > Enhanced disconnection and isolation > Tripping function > Easy to install > Highly reliable solution Function Reliability and guaranteed safety combined with low maintenance costs are vital when selecting components for integration in electrical systems. With its proven switching technology and tripping...

Open the catalog to page 2
Catalogue extract : INOSYS LBS Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications - 3

Load Break Switches incorporating tripping function for AC applications from 160 to 800 A, up to 1000 VAC Application examples: local and remote safe disconnection for AC applications Machine emergency switching Building emergency switching Switchboard cabinet Local safety break Machine control Red/yellow handle Motor Feeder output Power electronics: UPS, backfeed, battery protection INOSYS LBS Incoming section Mobile equipment Distribution enclosure with automatic switching device INOSYS LBS Foot crane Input Output Aux mains Site enclosure with a general break external handle...

Open the catalog to page 3
Catalogue extract : INOSYS LBS Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications - 4

Load Break Switches incorporating tripping function for AC applications from 160 to 800 A, up to 1000 VAC 1. INOSYS LBS 800 A with tripping function 2. INOSYS LBS 800 A without tripping function 3. oor interlocked external operation handle 4. irect operation handle 5. Shaft for external handle 6. Auxiliary contact 7. Tripping coil 8. Inter-phase barrier 9. Terminal shrouds 10. Terminal screens 11. Captive nut 12. Holding insert 13. Terminal lugs References INOSYS LBS Switch with tripping function Rating (A) Frame size S2 type handle Black IP55 Switch without tripping function Tripping coil...

Open the catalog to page 4
Catalogue extract : INOSYS LBS Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications - 5

Load Break Switches incorporating tripping function for AC applications from 160 to 800 A, up to 1000 VAC Accessories irect operation handle Handle type Handle colour Frame size Example of application As the handle is interlocked in the “ON” position the operator must safely disconnect and isolate the circuit prior to accessing the panel for maintenance procedures. Opening the door when the switch is in the “ON” position can only be done by defeating the interlocking function with the use of a dedicated tool (authorised persons only). The interlocking function is restored when the door is...

Open the catalog to page 5
Catalogue extract : INOSYS LBS Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications - 6

Load Break Switches incorporating tripping function for AC applications from 160 to 800 A, up to 1000 VAC Accessories (continued) Alternative S-type handle cover colours Handle colour Light grey ark grey Use For S2 and S2L type single grip handles. Reference Other colours: please consult us. Auxiliary contact Frame size Connection type NO/NC standard Characteristics Changeover type: NO/NC, IP2 with front operation. 0 000 operations. Maximum per switch. Use The same auxiliary contact can be used to provide position and tripping information. The function of the auxiliary contact depends on...

Open the catalog to page 6
Catalogue extract : INOSYS LBS Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications - 7

Load Break Switches incorporating tripping function for AC applications from 160 to 800 A, up to 1000 VAC Tripping coil Connector: 1.5 mm , push in type. Maximum one tripping coil per switch. Safe and easy coil replacement by using standard tools. Use Remotely activates the tripping mechanism of the switch via shunt trip or undervoltage release coil. Shunt trip coil Frame size Shunt trip coil Other voltage ratings available, please consult us. Undervoltage release Frame size Other voltage ratings available, please consult us. Characteristics Shunt trip coils AC type (±10%) Undervoltage...

Open the catalog to page 7
Catalogue extract : INOSYS LBS Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications - 8

Load Break Switches incorporating tripping function for AC applications from 160 to 800 A, up to 1000 VAC Accessories (continued) Terminal shroud Advantages Perforations for thermographic inspection / voltage check without the need to remove the shrouds. Sealable in position. Includes break-off marks for precise adaptation to cables or insulated bars. Use For top or bottom protection against direct contact with terminals or connection parts; provides IP4 protection and phase separation. Pack (unit) (1) Compatible with the holding insert which can be fitted to lock the shrouds in place....

Open the catalog to page 8
Catalogue extract : INOSYS LBS Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications - 9

Load Break Switches incorporating tripping function for AC applications from 160 to 800 A, up to 1000 VAC Voltage tap Use Allows connection of voltage sensing or power cables, with fast-on connection. Pack (unit) Frame size Characteristics Characteristics according to IEC 60947Thermal current Ith (40°C) Rated impulse withstand voltage Uimp (kV) Rated insulation voltage Ui (V) Frame size Rated operational currents Ie (A) Utilisation category Rated voltage Operational power in AC-23 (kW) 400 VAC without pre-break AC (kW) (2) Rated short-time withstand current - Icw 1s (kA rms) Rated...

Open the catalog to page 9
Catalogue extract : INOSYS LBS Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications - 10

Load Break Switches incorporating tripping function for AC applications from 160 to 800 A, up to 1000 VAC imensions (in/mm) INOSYS LBS with tripping function Frame size

Open the catalog to page 10
Catalogue extract : INOSYS LBS Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications - 11

Load Break Switches incorporating tripping function for AC applications from 160 to 800 A, up to 1000 VAC INOSYS LBS without tripping function Frame size

Open the catalog to page 11
Catalogue extract : INOSYS LBS Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications - 12

Load Break Switches incorporating tripping function for AC applications from 160 to 800 A, up to 1000 VAC imensions for external handles (mm) F2 frame size Front operation Handle type Door drilling with trip Front operation Handle type Door drilling For external side operation on the left, please order the S2 handle reference 142A2111 for case sizes F2 and F3. Please consult us if you require a device with side operation on the right. F frame size Front operation Handle type Door drilling with trip Front operation Handle type Door drilling For external side operation on the left, please...

Open the catalog to page 12
Catalogue extract : INOSYS LBS Load Break Switches incorporating tripping function from 100 to 800 A, up to 1000 VAC AC applications - 13

Load Break Switches incorporating tripping function for AC applications from 160 to 800 A, up to 1000 VAC All mounting orientations are possible. erating may apply - please consult us.

Open the catalog to page 13

All SOCOMEC catalogs and technical brochures

  1. DIRIS Q800

    4 Pages

  2. SURGYS® E10

    2 Pages

  3. COMO CS

    6 Pages