Catalogue extract: ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98
1 /
20Pages
Catalog excerpts

SHORT FORM CATALOGUE ATYS & SIRCOVER Transfer Switch Equipment for your power availability Innovative Power Solutions
Open the catalog to page 1
ATyS UL 1008 Transfer switches Motorized Transfer Switching Equipment from 100 to 400 A The solution for > Commercial > Light Industry > Residential applications Strong points > Robust and reliable design > Compatible with virtually any ATS controls > On-load manual operation > Maintenance free Function ATyS non-automatic transfer switches are designed for use in total system optional standby applications for the safe transfer between a normal and an alternate power source. The changeover is done in open transition and with minimum supply interruption during transfer ensuring full...
Open the catalog to page 2
Motorized Transfer Switching Equipment from 100 to 400 A Typical applications The ATyS UL 1008 range provides safe transfer for mains/mains, mains/genset and genset/genset applications. Genset / Genset Mains / Genset Mains / Mains Part of a globally recognized range The ATyS UL 1008 is part of a large family of products including a complete range of remotely operated and fully automatic transfer switches that comply to IEC and GB standards. The ATyS range is a world renowned product family trusted by some of the largest manufacturers in the genset industry. The key to success has been...
Open the catalog to page 3
Motorized Transfer Switching Equipment from 100 to 400 A Bridging bars Terminal screens Auxiliary contact Accessories Terminal screens Position top / bottom top / bottom top / bottom top / bottom For upstream and downstream protection, order the reference once. Reference Use Top and bottom protection against direct contact with terminals or connection parts. Bridging bars Use For bridging power terminals on the top or bottom side of the switch. When ordering one reference is required per switch. No. bridging bar
Open the catalog to page 4
Motorized Transfer Switching Equipment from 100 to 400 A Accessories (continued) Auxiliary contacts (additional) Use Pre breaking and signalling of positions I and II: Each reference provides a single NO/NC contact. (Note : The motorization includes 3 x NO position auxiliary contacts as standard) A maximum of 2 Aux contacts per position may be added. Spares Motorization module Ref. Spare part motorization Used for ATyS reference 100 A Terminals lugs (in/mm) Mounting orientation ATyS 100 to 400 A Short Form Catalogue 2
Open the catalog to page 5
Motorized Transfer Switching Equipment from 100 to 400 A Characteristics according to UL 1008 (Optional standby) 100 to 400 A Frame General use rating Operation voltage 2 P / 3-4 P Short circuit rating with ANY CIRCUIT BREAKER (kA/ms) Short circuit rating at 600 VAC (kA) with fuses Type of fuse Max. fuse rating (A) Short circuit rating at 600 VAC with SPECIFIC CIRCUIT BREAKER (kA) Square D JJ breaker 250 A 2 poles 240 VAC / 3-4 poles 480 VAC Schneider Electric NSX-F 160 A 3-4 poles 480 VAC Operational power / current max Operational 1 ph 240 VAC Total system (A) 240 VAC Resistive load (A)...
Open the catalog to page 6
Motorized Transfer Switching Equipment from 100 to 400 A Dimensions (in/mm) 100 to 400 A Transfer switch dimensions Minimum enclosure dimensions recommended C Door cut-out for front panel 5.43in 138mm Short Form Catalogue 2014-2015
Open the catalog to page 7
SIRCOVER UL 1008 Transfer switches Manual Transfer Switching Equipment 100 to 1200 A The solution for > Manufacturing industry > Power distribution > Domestic Stable positions Compact design On load switching Reliability Function SIRCOVER UL 1008/98 are heavy duty manual transfer switches. They ensure switching transfer of sources or transfer of two low voltage circuits on load as well as their safe disconnection. These switches are extremely durable and are tested and approved for use in the most demanding applications, such as resitive load or total system applications. Advantages Stable...
Open the catalog to page 8
Manual Transfer Switching Equipment 100 to 1200 A Typical application The SIRCOVER UL 1008 range provides safe transfer and disconnection at all levels within your LV installation. They can be used for changing motor phase for rotation control or equipmement grounding as well. Normal power supply to genset transfer The source transfer will be operated safely even under on-load or over-load conditions SOCOMEC solution up to 1200 A UL 1008 Manual Transfer Switch From 100 to 400 A for resistive and total systems applications UL 98 versions on request UL 1008 and UL 98 Manual Transfer Switch...
Open the catalog to page 9
Manual Transfer Switching Equipment 100 to 1200 A References UL 1008 Switch body External handle Direct handle Shaft for external handle Bridging bars Contact NO/NC 4159 0021 Low level Terminal screens Auxiliary contacts 4150 3080 Contact NO/NC as standard Short Form Catalogue 2014-2015
Open the catalog to page 10
Manual Transfer Switching Equipment 100 to 1200 A Accessories Direct handle Handle type Use The handle interlocking function prevents the user from opening the door of the enclosure when the switch is in the "ON" position. Opening the door when the switch is in the "ON" position is possible by defeating the interlocking function (Not S5 and V handles) with the use of a tool (authorized persons only). The interlocking function is restored when the door is re-closed. Shaft for external handle Length Length Dimension Dimension (in) (mm) X (in) X (mm)
Open the catalog to page 11
Manual Transfer Switching Equipment 100 to 1200 A Bridging bars Use Creation of a common point, above or below the switch, between positions I and II. No. bridging bar 2 3 4 2 3 4 3 4 3 4 Terminal protection screen Use Top or bottom protection against direct contact with terminals or connecting parts. No. of poles 2P / 3P 4P 2P / 3P 4P 6P 4P 3P 4P Auxiliary contacts Use Pre-break and signalisation of positions . For low level ACs and other ACs contact us. Low level NO/NC on position 1 and 2 NO/NC auxiliary contact Terminal lugs Use Connection of bare copper cables onto the terminals...
Open the catalog to page 12
Manual Transfer Switching Equipment 100 to 1200 A Characteristics Characteristics according to UL 1008 100 to 1200 A General use rating (A) Operation voltage 2 P / 3-4 P Short circuit rating with circuit breaker (kA/ms) Short circuit rating at 600 VAC (kA) Type of fuse Max. fuse rating (A) Short circuit rating at 600 VAC with SPECIFIC CIRCUIT BREAKER (kA) Square D JJ breaker 250 A 2 poles 240 VAC / 3-4 poles 480 VAC Schneider Electric NSX-F 160 A 3-4 poles 480 VAC Operational power / current max Operational 1 ph 240 VAC Total system (A) 240 VAC Resistive load (A) Operational power / current...